Angle rotor 30 x 1.5/2.0 ml for Sigma 2-19P

Item number: SIGMA_Z0058>

EAN: 4064343399364

Category: SIGMA

Manufacturer: Sigma Laborzentrifugen

1.245,00 €

Excluding 19% VAT. , plus shipping (Standard 2500)

(including 19% VAT. 1.481,55 €)


Angle rotor 30 x 1.5/2.0 ml for Sigma 2-16P

The angle rotor 30 x 1.5/2.0 ml for Sigma 2-16P is designed for laboratories that require reliable and efficient centrifugation in high volumes. With its high sample capacity and various adapters, it is ideally suited to meet a variety of requirements. In addition, its robust construction facilitates daily routine work and ensures consistent results. Versatile features and technical details

This rotor is designed to meet the ever-growing demands of modern laboratory environments. Thanks to its angular design, it ensures uniform separation of samples and is ideal for demanding procedures in biology, medicine, pharmacy and research. Careful workmanship enables stable operation, even at high speeds, providing a reliable basis for reproducible results.

Important features and data at a glance:
- Rotor type: Angle rotor for efficient sample distribution
- Capacity: 30 x 1.5/2.0 ml reaction tubes for large sample numbers
- Compatibility: Designed for the Sigma 2-16P universal centrifuge
- Adapters: Available for 0.25/0.4 ml, 0.5/0.75 ml and 0.2 ml PCR tubes
- Hermetic lid: Guarantees safe and contamination-free handling
- CE marking: Complies with European standards for safety and quality
- ISO certification: Ensures strict quality standards

In addition, the rotor is resistant to typical laboratory chemicals and can be autoclaved if necessary. The hermetic seal reduces the risk of contamination, which is of great importance in many areas of molecular biology and medical research. The manufacturer's website provides comprehensive information on maintenance and care so that you can enjoy its benefits for a long time to come.

Certifications and standards

Quality and safety standards are essential, especially in sensitive work areas such as clinical or industrial laboratories. This rotor complies with both CE requirements and the relevant ISO standards. This means that strict requirements for manufacturing processes, materials used and product performance are met. Compliance with these guidelines gives users the assurance that they can rely on a reliable and tested product.

Specific application examples

The rotor is used in a wide variety of laboratory areas. The following applications are particularly noteworthy:

- Molecular biology: Rapid and gentle centrifugation of DNA and RNA samples to obtain high-quality nucleic acids for further analysis. - Biochemical analyses: Separation of proteins, peptides and enzymes that are being investigated in the context of research or product development. - Clinical diagnostics: Preparation of blood or serum samples for specific tests where reliable sample processing is a top priority.
- Pharmaceutical research: Investigation of new active ingredients and formulations in reaction vessels that require reproducible separation of the components.

The various adapters also allow you to work with smaller vessel volumes, including 0.2 ml PCR vessels. This enables flexible use for a variety of modern laboratory methods, such as polymerase chain reactions (PCR).

FAQs

What rotation speeds are possible?

The maximum achievable speed depends on the centrifuge model. In combination with the appropriate universal centrifuge, high speeds are usually possible for fast separation in a short time window. Detailed information and recommended operating parameters can be found in the technical documentation.

Can the adapters be retrofitted?

Yes, different adapter variants are available, each of which can be purchased in sets. This allows the rotor to be adapted to different vessel sizes without having to purchase a completely new rotor.

How can contamination be prevented?

The hermetic lid ensures that samples are securely sealed during centrifugation. In addition, the entire system is autoclavable, allowing thorough sterilisation after each use. Regular cleaning and inspection of the seals complete the hygiene management process.

What maintenance intervals are recommended?

In general, it is advisable to check the rotor regularly for damage, wear and contamination. The manufacturer's documentation provides precise intervals and instructions for care and maintenance. In addition, the fit of all moving parts should be checked after each autoclaving.

Conclusion

This rotor meets the high expectations of professional users who value reliability, flexibility and safety. Its sophisticated design, robust materials and the option of using different vessel sizes make it the ideal choice for laboratories that regularly need to centrifuge samples in varying volumes. With its certified standards and compatibility with the Sigma 2-16P, it is a long-lasting and powerful tool that plays an essential role, especially in research-intensive environments and clinical diagnostics.


Rotor type: angle rotor
Shipping weight: 5,00 Kg
Product weight: 5,00 Kg
max rpm max rcf
SIGMA 2-16P 12.000 16.099
Information on product safety
Manufacturer information:
SIGMA Laborzentrifugen GmbH
An der unteren Söse 50
37520 Osterode, Deutschland
[email protected]
Responsible person:
Mr. Schuldt
0049 30 403 667 940
[email protected]