P8000 |
P8000-T |
P8100 |
P8100-T |
Measuring method |
Optical rotation, int. sugar scale, concentration, spec. rotation, user-defined |
Optical rotation, int. sugar scale, concentration, spec. rotation, user-defined |
Optical rotation, int. sugar scale, concentration, spec. rotation, user-defined |
Optical rotation, int. sugar scale, concentration, spec. rotation, user-defined |
Measuring range |
±90° ±259° Z 0-99,9 g/ml |
±90° ±259° Z 0-99,9 g/ml |
±90° ±259° Z 0-99,9 g/ml |
±90° ±259° Z 0-99,9 g/ml |
Measuring units |
Angle [°, °Z] conc. [g/100 ml] user defined |
Angle [°, °Z] conc. [g/100 ml] user defined |
Angle [°, °Z] conc. [g/100 ml] user defined |
Angle [°, °Z] conc. [g/100 ml] user defined |
Resolution |
0,001° 0,01 °Z 0,1 g/ml |
0,001° 0,01 °Z 0,1 g/ml |
0,001° 0,01 °Z 0,1 g/ml |
0,001° 0,01 °Z 0,1 g/ml |
Accuracy |
±0,003° ±0,01 °Z ±0,5 g/100 ml |
±0,003° ±0,01 °Z ±0,5 g/100 ml |
±0,002° ±0,01 °Z ±0,5 g/100 ml |
±0,002° ±0,01 °Z ±0,5 g/100 ml |
Reproducibility |
0,002° |
0,002° |
0,002° |
0,002° |
Measuring time ±90° |
1 s |
1 s |
1 s |
1 s |
Light source |
1 LED with filter |
1 LED with filter |
1 LED with filter |
1 LED with filter |
Wavelength |
589 nm others optional |
589 nm others optional |
589 nm others optional |
589 nm others optional |
Wavelength selection |
One fixed wavelength |
One fixed wavelength |
One fixed wavelength |
One fixed wavelength |
Connection for temperature sensor |
Special tube with PT100 temperature sensor required |
Special tube with PT100 temperature sensor required |
Special tube with PT100 temperature sensor required |
Special tube with PT100 temperature sensor required |
Temperature measurement |
0-99,9 °C |
0-99,9 °C |
0-99,9 °C |
0-99,9 °C |
Temperature resolution |
0,1 °C |
0,1 °C |
0,1 °C |
0,1 °C |
Temperature accuracy |
±0,2 °C |
±0,2 °C |
±0,2 °C |
±0,2 °C |
Temperature reading point |
Tube |
Tube |
Tube |
Tube |
Temperature control |
- |
PT31 Peltier thermostat (water) with fast closure system |
- |
PT31 Peltier thermostat (water) with fast closure system |
Range of temperature control |
- |
15-40,0 °C |
- |
15-40,0 °C |
Accuracy of temperature control |
- |
±0,2 °C |
- |
±0,2 °C |
Max. length of tube |
220 mm |
220 mm |
220 mm |
220 mm |
Sensitivity |
min 0,1 % (OD3) |
min 0,1 % (OD3) |
min 0,1 % (OD3) |
min 0,1 % (OD3) |
Calibration |
Automatic (menu-driven) |
Automatic (menu-driven) |
Automatic (menu-driven) |
Automatic (menu-driven) |
Display |
LCD TFT 5.7 " 640x480 pixel color display (VGA) |
LCD TFT 5.7 " 640x480 pixel color display (VGA) |
LCD TFT 5.7 " 640x480 pixel color display (VGA) |
LCD TFT 5.7 " 640x480 pixel color display (VGA) |
Operation |
Touchscreen |
Touchscreen |
Touchscreen |
Touchscreen |
Measured data storage |
999 measurements |
999 measurements |
999 measurements |
999 measurements |
Interfaces |
RS-232 (printer) USB (data export, firmware updates) Ethernet (LIMS, remote monitoring) |
RS-232 (printer) USB (data export, firmware updates) Ethernet (LIMS, remote monitoring) |
RS-232 (printer) USB (data export, firmware updates) Ethernet (LIMS, remote monitoring) |
RS-232 (printer) USB (data export, firmware updates) Ethernet (LIMS, remote monitoring) |
Operating voltage |
90-250 V 50/60 Hz |
90-250 V 50/60 Hz |
90-250 V 50/60 Hz |
90-250 V 50/60 Hz |
Dimensions in cm |
64,5 x 20,0 x 36,0 |
64,5 x 20,0 x 36,0 |
64,5 x 20,0 x 36,0 |
64,5 x 20,0 x 36,0 |
Weight |
28 kg |
28 kg |
28 kg |
28 kg |