HMC-Europe Steam sterilzer HV series - ProfiLab24 GmbH
99
100
24
4
stars -
Professional service
Customer
Young team with a lot of ambition and quick answers to all questions. We needed a complete laboratory equipment for our new location. The team of Profiab24 has arranged everything.
HMC-Europe Steam sterilzer HV series
Item number: HMC_24004
EAN: 4064343163774
Manufacturer:
HMC-Europe
starting from
8.075,00 €
Manufacturers suggested retail price:
8.500,00 €
Excluding 19% VAT. ,
plus
(Sperrgut)
(including 19% VAT. 9.609,25 €)
HMC-Europe Steam sterilzer HV series. ProfiLab24.com laboratory supplies and laboratory equipment with top advice and 24H service
- Model
-
There are variations of this item. Please select the variation you wish.
HMC-Europe Steam sterilzer HV seriesThe tireless for standard tasks - ingeniously simple and robust.
QuicklockThe simpler the design, the safer the lock! The lock can be opened and closed with one finger. Radially locking bolts are moved without applying any force.The passive chamber seal operates with virtually no wear.
Vier Größen
- HV 25 Chamber volume of 28 Lit.; Effective useful volume of 25 Lit.
- HV 50 Chamber volume of 54.2 Lit.; Effective useful volume of 50 Lit.
- HV 85 Chamber volume of 98.8 Lit.; Effective useful volume of 85 Lit.
- HV 110 Chamber volume of 123.7 Lit.; Effective useful volume of 110 Lit.
The lid gasket is not subjected to any mechanical friction and can easily be replaced if required. The weight of the lid is completely balanced by a torsion spring. Effortless opening and closing. Any condensate which drips off the lid is collected and fed into the spent-steam condenser. The device and floor are kept dry.
Programs at the push of a button:
- The most important programs are pre-installed and can be opened at the push of a button:
- Sterilization of solids: With fast release of steam
- Sterilization of liquids: With variable natural cooling
- Sterilization of liquids: With rapid cooling for thermolabile materials
- Sterilization of liquids: With subsequent reheat cycle
- AGAR program: Prepares AGAR and keeps it ready for processing (thermostatic heating)
- Night program: Timer-controlled, load in the evening - sterile and ready for removal in the morning down to the minute, even over the weekend!
- Waste sterilization: Mixed load with a low liquid content
- Automatic standby operation to save energy
Dual sensor system
Precise temperature control with additional pressure monitoring. This allows for controlled excess pressure during the heating phase, which reduces the batch time Bright display with program and progress indicators.
Thermolock with sterilization time controlThe German ordinance on pressure vessels TRB 402 and DIN EN 61010-2 prescribe a thermolock for the sterilization of liquids. This thermolock prevents injuries do the operating personnel due to boiling delay. This hazard should be controlled directly in the substance at risk for boiling delay. The lid can only be opened once the media temperature has also dropped below the reference value after pressure equalization. All parameters can be set individually before starting the program, and cannot be modified after program start for safety reasons. Reliable sterilization is ensured in this manner.
Heating
- Electrical, with maximum efficiency, directly in the feed water
- 3-level protection against overheating
Exhaust air filter
Safety for individuals and the environment. Option for safe, emission-free sterilization of highly infectious germs and genetically modified materials. During the venting phase, the steam displaces unsterilized residual air from the chamber and passes it through a filter system. The surrounding air is protected against contamination as the cycle is running. Naturally, in-line sterilization of the exhaust air filter is performed. Due to the design, condensate sterilization is a matter of course. Any condensate which precipitates flows back into the chamber and gets sterilized. Discharge can be done safely.
The autoclaves are supplied as standard without baskets as there are so many different fitting options.
Design:
|
vertical
|
Width (autoclave):
|
480 mm540 mm660 mm
|
Pressure max. (autoclave):
|
1.2 bar1.4 bar1.6 bar2.2 bar
|
Height (autoclave):
|
950 mm1000 mm1040 mm1180 mm
|
Diameter of vessel:
|
240 mm300 mm420 mm
|
Height or depth of vessel:
|
550 mm615 mm710 mm795 mm
|
Power (autoclave):
|
1.5 kW2.0 kW3.0 kW4.0 kw
|
Vessel material:
|
stainless steel SUS 304
|
Temperature max. (autoclave):
|
123°C126°C128°C135°C
|
Depth (autoclave):
|
460 mm530 mm650 mm
|
Volume (autoclave):
|
25 l50 l85 l110 l
|
HMC-Europe HV series |
HV 25 |
HV 50 |
HV 85 |
HV 110 |
Chamber volume |
28 l |
54,2 l |
98,8 l |
123,7 l |
Useful volume |
25 l |
50 l |
85 l |
110 l |
Chamber dimensions (Ø x H) mm |
240 x 550 |
300 x 710 |
420 x 615 |
420 x 795 |
Exterior dimensions (WxDxH) mm |
480 x 460 x 950 |
540 x 530 x 1040 |
660 x 650 x 1000 |
660 x 650 x 1180 |
Required space (WxDxH) mm |
495 x 750 x 1250 |
560 x 810 x 1400 |
680 x 930 x 1450 |
680 x 930 x 1650 |
Electrical power |
1.5 kW |
2.0 kW |
3.0 kW |
4.0 kW* |
Weight |
41 kg |
57 kg |
71 kg |
81 kg |
Power supply |
AC 230 V/240 V |
AC 230 V/240 V |
AC 230 V/240 V |
AC 230 V/240 V |
Allowable operating temperature |
130°C |
139°C |
133°C |
127°C |
Selectable operating temperature |
105°C - 126°C |
105°C - 135°C |
105°C - 128°C |
105°C - 123°C |
Warming temperature |
45°C - 60°C |
45°C - 60°C |
45°C - 60°C |
45°C - 60°C |
Maximum operating pressure |
1.4 bar |
2.2 bar |
1.6 bar |
1.2 bar |
Automatic start |
1 minute to 7 days |
1 minute to 7 days |
1 minute to 7 days |
1 minute to 7 days |
Sterilization time |
1 to 250 minutes |
1 to 250 minutes |
1 to 250 minutes |
1 to 250 minutes |
Lock |
Quick lock with one-lever operation |
Quick lock with one-lever operation |
Quick lock with one-lever operation |
Quick lock with one-lever operation |
Vessel material |
SUS304 (high-grade stainless steel) |
SUS304 (high-grade stainless steel) |
SUS304 (high-grade stainless steel) |
SUS304 (high-grade stainless steel) |
Documentation |
Integrated printer USB (optional) |
Integrated printer USB (optional) |
Integrated printer USB (optional) |
Integrated printer USB (optional) |
Safety systems |
Electro-mechanical safety lock, safety valve, low-water interrupt, overpressure protection switch, overheating protection switch, circuit breaker, fault indicator (visual and audible) |
Load capacity |
|
|
|
|
Square laboratory flask 500 ml |
8 |
18 |
26 |
52** |
Erlenmeyer flask 500 ml |
4 |
12 |
16 |
32** |
Round laboratory flask 1000 ml |
4 |
21 |
16 - 18 |
16 - 18 |
Erlenmeyer flask 1000 ml |
2 |
6 |
10 |
10 |
Solid materials approx. kg |
8 |
15 |
25 |
29 |
Waste approx. kg |
8 |
15 |
25 |
28 |
* higher heating power on request
**with intermediate pan