Tuttnauer Fully Automatic Benchtop Sterilizers EL Series

Item number: TUTT_24001>

EAN: 4064343261418

Category: Tuttnauer

Manufacturer: Tuttnauer

Price on application
Type

There are variations of this item. Please select the variation you wish.


Tuttnauer EL - Fully Automatic Benchtop Sterilizers

With higher capacity and better performance, Tuttnauer's EL Laboratory line of fully automatic, microprocessor controlled, benchtop, steam sterilizers provides safe, economical and effective sterilization. Integrated reservoir for water feed, with water level control and steam recirculation saves on demineralized water consumption and enables the autoclave to be independent of a water supply. External heating elements make the sterilizer easy to clean.

The Tuttnauer benchtop front loading laboratory autoclave is available in chamber sizes from 23 liters to 160 liters. EL models have an advanced microprocessor based control panel.

Sterilization Applications

  • Liquids such as nutrient media and buffer solutions
  • Solid items such as pipettes, tubes and filters
  • Glassware and plastic articles
  • Waste sterilization

The various applications can be carried out using the autoclave's standard programs. Additional options ensure more control over results and optimal, safe and repeatable sterilization processes.

Control and Documentation

  • Control Features
    • High precision control system for perfect sterilization results
    • Password protection allows for secure access control
    • Independent temperature and pressure monitoring
    • Cycle information recovery in the case of power failure or cycle interruption
    • Fail Alert - Indicates cycle failure or interruption
    • Door Alert - Indicates the door is unlocked
    • RS 232 PC Connection Port for direct software updates and remote maintenance
  • Built in Printer
    • The laboratory line can be supplied with a built-in printer to document the performed cycle, in addition to a comprehensive LCD display. This feature is optional.
  • ADMC Software
    • The ADMC software allows complete control and monitoring of up to eight sterilizers. The software retrieves data, creates graphs, tables and print outs, controls the autoclave and shows real-time data.

Safety Features

  • Door Safety
    • The autoclave lids are designed with a number of independent mechanical and digital safety features.
    • A safety device prevents the operator from opening the door when the chamber is pressurized
    • Steam is not allowed to enter the chamber when the door is open
    • A cycle cannot start if the door is open or not properly locked
    • The door cannot unlock until liquid temperature reaches the predetermined end temp
    • The door cannot unlock until chamber pressure reaches room pressure
    • Temperature Activated Door Lock - The door will not open until the temperature is below a specified safe level
  • General Safety Features
    • Double Independent Monitoring: The combined electronic and mechanical monitoring guarantees accurate results. The operator has two independent means to monitor temperature and pressure.
    • Safety Valves: The chamber is equipped with safety valves - if the pressure exceeds the allowed limit the safety valves will discharge
    • Built-in Steam Generator Safety: A water level monitoring system maintains a constant water level and ensures safe operation of the heaters

Quality Features

  • The chamber is constructed of long lasting 316Ti grade stainless steel with superior corrosion resistance
  • The generator is made from stainless steel
  • The autoclave automatically switches to standby mode if no buttons or switches are operated for four hours
  • The autoclave is designed for easy servicing allowing maintenance access to all components
  • Drain Protection: The exhaust drain is mixed with cold tap water that cools the exhaust?s temperature before reaching the drain

Sterilizer Directives and Standards Compliance

  • Tuttnauer's high quality laboratory autoclaves comply with the strictest international directives and standards.
  • Pressure Equipment: PED 97/23 EEC, EN 10028-7, ASME Code Sec VIII
  • Safety: IEC/UL/EN61010-1, IEC 61010-2-040, EN 61326
  • Sterilization: DIN 58951 Series, ISO 17665-1:2006
  • Quality System: ISO 9001:2000, ISO 13485:2003

Design: horizontal
Width (autoclave): 510 mm600 mm660 mm880 mm
Height (autoclave): 365 mm450 mm525 mm700 mm
Diameter of vessel: 250 mm310 mm380 mm500 mm
Height or depth of vessel: 400 mm490 mm500 mm690 mm750 mm
Vessel material: stainless steel 1.4571 (AISI 316 Ti)
Depth (autoclave): 545 mm695 mm696 mm767 mm875 mm967 mm
Volume (autoclave): 23 l40 l62 l85 l110 l160 l
Type Chamber Dimensions
(Ø x Depth) (mm)
Chamber Volume
(Liters)
External Dimensions
(W x H x D) (mm)
2540 EL 250 x 400 23 510 x 365 x 545
3150 EL 310 x 500 40 600 x 450 x 695
3850 EL 380 x 490 62 660 x 525 x 695
3870 EL 380 x 690 85 660 x 525 x 875
5050 EL 500 x 500 110 880 x 700 x 767
5075 EL 500 x 750 160 880 x 700 x 967