Herolab MicroCen M/ MicroCen MR microlitre centrifuges

Item number: HERO_22007

EAN: 4064343548168

Category: Centrifuges, Centrifuges with vortex function

Manufacturer: Herolab

starting from 3.570,00 €

Excluding 19% VAT. , plus shipping (Sperrgut)

(including 19% VAT. 4.248,30 €)
Model

There are variations of this item. Please select the variation you wish.


Herolab MicroCen M/ MicroCen MR microlitre centrifuges
with and without cooling, touchscreen display

MicroCen M/ MicroCen MR - Easy to operate

  • Microprocessor controlled
  • especially for microlitre tubes
  • Maximum capacity: 30 x 2.2 ml or 12x10 ml AOR tubes
  • 6 angle rotors, 1 swing-out rotor, 1 microhaematocrit rotor
  • Speed: 500 to 16,000 min-1 / 22,000 min-1, in steps of 100 min-1
  • g-value (RZB): 20,464 x g / 37.878 x g, in steps corresponding to 100 min1
  • Signal at the end of the run and in the event of an error message
  • Timer: touchscreen: h, m 99:59, in 1 min. steps
  • HOLD for longer runs / PULSE for short runs
  • 9 acceleration and deceleration ramps
  • Maintenance-free brushless induction drive
  • Stainless steel chamber with additional armouring
  • Overspeed protection, unbalance detection and switch-off
  • Motorised lid lock, automatic lid opening, emergency lid release
  • LCD display to show the preselected and current values for speed/g-value, time and temperature (temperature only with cooled MicroCen MR)

Dimensions (H x W x D) (centrifuges): 310 x 334 x 740 mm310 x 334 x 490 mm
Display speed / g-force: speed and g-force
Acceleration max.: 30 s bis 1,5 min
Deceleration max.: 40 s bis 2,5 min
Lid release / lid open: Auto lid open, emergency release of the lid
Display (centrifuges): LCDTouchscreen, coloured
Speed max.: 16000 rpm22000 rpm
Speed min.: 500 rpm
Speed range (centrifuges): 500 - 16000 rpm500 - 22000 rpm
Speed increments (Centrifuges): 100 rpm
Field of application (centrifuges): Clinical laboratoriesHospitals
Frequency (Centrifuges): 50/60 Hz60 Hz
Weight approx. (centrifuges): 32 kg49,5 kg
Capacity/capacity max.: 30 x 2,2 ml
Cooling (Centrifuges): with coolingwithout cooling
Microprocessor controlled: yes
Motor: Maintenance-free induction drive motor
RCF max.: 20464 xg37878 xg
Rotor type: angle rotorswing-out rotor
Safety (centrifuges): Automatic lid openinglid lockSpeed controlEmergency releaseOvertemperature fuseUnbalance monitoring and switch-off
Voltage (centrifuges): 115 V230 V
Centrifuge type: microcentrifugeHigh-speed centrifugeBenchtop centrifuge
available models Cooling Voltage Phases Hz
MicroCen M with touchscreen 230 V 1 50/60 Hz
MicroCen M with touchscreen 115 V 1 60 Hz
MicroCen MR with touchscreen cooled 230 V 1 50/60 Hz
MicroCen MR with touchscreen cooled 115 V 1 60 Hz

Touchscreen control panel MicroCen M and MicroCen MR
Display TFT monitor
User interface touch screen
Languages German, English
Number of programmes 50
Time setting Hours, minutes 99:59
Real Run Time (RRT) display, timer starts,
when the preset speed is reached
YES, selectable
''HOLD'' for long run YES
''SHORT'' for short runs YES
Relative centrifugal acceleration RZB in x g Yes, in steps of 10 x g
Speed in min-1 Yes, in steps of 100 min-1
Speed and RZB display Both are permanently displayed
RPM, g-value, time and temperature Current and preset values are permanently displayed
Rototype, maximum speed, acceleration and deceleration ramps Permanent display
Acceleration and deceleration ramps can be selected individually 9 ramps in steps of 15 seconds from 0 -120 seconds
in the range from 0 to 1,000 min-1
Dynamic electric braking system YES
Fast braking function with maximum force YES
Temperature range for centrifuges with cooling -20 °C to +40 °C in steps of 1 °C,
Tmin at maximum speed <4 °C
Cooling at standstill YES
Fast pre-cooling YES
Sample protection YES
Overheating protection Yes, with MicroCen MR
Automatic speed reduction when
input of a density > 1.2 g/cm3
YES
Acoustic signal at end of run or error message YES, selectable
Automatic lid opening after the run selectable
Password protection YES, selectable

Herolab centrifuge MicroCen M MicroCen MR
Maximum capacity 30 x 2.2 ml 30 x 2.2 ml
Maximum speed 16,000 min-1 22,000 min-1
Max. g-value/RZB (depending on rotor) 20,464 x g 37.87 x g
Minimum speed > 500 min-1 > 500 min-1
Rotor detection APRI system = Automatic Positive Rotor Identification
for Herolab rotors
APRI System = Automatic Positive Rotor Identification
for Herolab rotors
Programmability 50 programmes 50 programmes
Display LCD display for current and preselected values LCD display for current and preselected values
User interface Control panel with buttons and a rotary knob Control panel with buttons and a rotary knob
Time preselection Touch screen: h, m 99:59, steps of 1 minute
''HOLD'' for longer runs / ''PULSE'' for short runs
Touch screen: h, m 99:59, steps of 1 minute
''HOLD'' for longer runs / ''PULSE'' for short runs
Speed preselection From 300 min-1 to maximum speed in steps of 100 min-1 From 300 min-1 to maximum speed in steps of 100 min-1
G-value preselection (RZB) In steps corresponding to 100 min-1 In steps corresponding to 100 min-1
Drive system Direct drive with self-centring system and brushless induction motor Direct drive with self-centring system and brushless induction motor
Speed accuracy ± 2 min-1 at 1,000 min-1 / ± 20 min-1 at maximum speed ± 2 min-1 at 1,000 min-1 / ± 20 min-1 at maximum speed
Acceleration time (depending on rotor) 30 seconds to 1.5 minutes 30 seconds to 1.5 minutes
Deceleration time (depending on rotor) 40 seconds to 2.5 minutes 40 seconds to 2.5 minutes
Acceleration/deceleration ramps 9 ramps in steps of 15 seconds from 0 to 120 seconds
in the range from 0-1,000 min-1
9 ramps in steps of 15 seconds from 0 to 120 seconds
in the range of 0-1,000 min-1
Brake system Dynamic electric braking system - Acoustic signal at the end of the run Dynamic electric braking system - Acoustic signal at the end of the run
Temperature preselection range n.a. -20 °C to +40 °C In steps of 1 °C
Cooling at standstill n.a. YES
Accuracy of temperature control n.a. ±2 °C on calibrated rotor
Temperature control system n.a. Bypass system
Sample protection n.a. n.a.
Overtemperature protection n.a. YES
Cooling system n.a. CFC-free coolant
Safety devices
Overspeed protection
Unbalance detection and switch-off
4-way lid lock
Automatic electrically operated lid lock with emergency release mechanism
Stainless steel chamber with additional armouring

Overspeed protection
Unbalance detection and switch-off
4-way lid lock
Automatic electrically operated lid lock with emergency release mechanism
Stainless steel chamber with additional armouring
Dimensions W x D x H (cm) 33.4 x 49.0 x 31.0 33.4 x 74.0 x 31.0
Dimensions W x D x H (inches) 13.1 x 19.3 x 12.2 13.1 x 29.1 x 1.2
Packaging dimensions (cm) 80.0 x 65.0 x 59.0 85.0 x 65.0 x 59.0
Packaging dimensions (inches) 31.5 x 25.6 x 23.2 33.5 x 25.6 x 23.2
Net weight 32.0 kg (70.5 lbs.) 49.5 kg (109.1 lbs.)
Gross weight 46.0 kg (101.4 lbs.) 64.0 kg (141.1 lbs.)

Information on product safety
Manufacturer information:
HeroLab GmbH Laborgeräte
Ludwig-Wagner-Str. 12
69168 Wiesloch, Deutschland
[email protected]
Responsible person:
Mr. Schuldt
0049 30 403 667 940
[email protected]