OHAUS multifunctional centrifuge Frontier 5000 Series Multi IVD

Item number: OHAUS_22002

EAN: 4064343284424

Category: Centrifuges, Centrifuges with vortex function

Manufacturer: OHAUS

starting from 1.738,50 €

Manufacturer’s suggested retail price: 1.830,00 €

Excluding 19% VAT. , plus shipping (Sperrgut)

(including 19% VAT. 2.068,82 €)
Model

There are variations of this item. Please select the variation you wish.


OHAUS multifunctional centrifuge Frontier 5000 Series Multi IVD

The OHAUS multifunctional centrifuge has been specially developed for laboratory environments that require a reliable and compact solution for processing blood and urine samples. With a maximum capacity of up to 6 x 50 ml, it impresses with its small footprint and the ability to flexibly accommodate various sample carriers. Compared to similar devices, it scores points with its intuitive user interface and smooth brushless motor, which enables an efficient and quiet working environment.

Versatile performance features in detail

In many laboratories, time is one of the most valuable resources. Thanks to the sophisticated design, installation, rotor replacement and cleaning are kept particularly simple. All operating elements can be handled precisely even when wearing gloves. The LCD display is illuminated and has two lines, making it easy to read parameters such as speed, running time or programme names. With a speed range from 200 rpm to 6000 rpm, the centrifuge is equipped for a wide variety of applications. The particularly compact dimensions save valuable floor space in the laboratory.

Important features and technical data: - Maximum relative centrifugal force of 4427 g for reliable results
- Sample load of up to 6 x 50 ml - ideal for common blood and urine tubes
- LCD with backlight for optimum readability
- Speed range from 200 rpm to 6000 rpm for flexible application options
- Low-noise brushless motor (? 56 ± 2 dB(A)) for a pleasant and productive laboratory atmosphere
- Programme memory for up to 99 programme data, including quick spin function
- CE (EU 2017/746) and FCC certified: Compliance with relevant norms and safety standards

In addition to these core data, the device has an intuitive control system that offers accelerated and decelerated start-ups (10 levels each) as well as a very finely adjustable time setting. Flexible rotor detection allows the user to utilise various angle and swing-out rotors. This also enables the processing of smaller tubes from 1.5 ml using suitable adapters. Safe operation is guaranteed thanks to the internal lid lock. In this way, the centrifuge combines maximum safety with easy handling, which is particularly important in routine-intensive laboratory processes.

Relevant certifications and standards

The device complies with the requirements of CE (EU 2017/746) and FCC. This ensures that all intended use and safety guidelines for medical and general laboratory applications are met. These certifications are a clear indication of reliable and compliant use in laboratories, which must fulfil high quality and safety standards.

Concrete application examples

  1. Separation of blood components: The centrifuge is ideal for separating blood plasma or other components in medical diagnostics thanks to its adaptation to different rotors.
  2. Analysis of urine samples: When analysing specific urine sediments, the flexible rotor configuration enables efficient preparation of samples in smaller or larger tubes.
  3. Centrifugation of cell cultures: It is also used in research and development environments to separate cell supernatants and cell pellets.
  4. Examination of pharmaceutical samples: For the work-up and clarification of sample solutions, it offers the necessary variability, from small volumes (1.5 ml) to standard sizes of 50 ml.

Frequently asked questions

How safe is operation during a centrifugation run?

The device has a reliable lid lock that cannot be opened during operation. This prevents accidental intervention and achieves a high level of work safety.

Which rotors can be used

In addition to an angled rotor for 6 x 50 ml, swing-out rotors for 5 ml tubes or 4 x 10 ml samples can also be used. This means that a wide range of laboratory requirements can be covered with little effort and suitable for everyday use.

Is it possible to set the speed and running time precisely?

Yes, the centrifuge offers precise control. The speed range goes from 200 rpm to 6000 rpm. Times can be set from 10 seconds to 99 hours, 59 minutes and 59 seconds. There is also a quick spin function for short centrifugation processes.

Is it suitable for use in confined spaces?

The compact design and low weight of around 14.2 kg make it suitable for use in confined spaces. This leaves enough space for other tools even in smaller laboratories.

Conclusion

This centrifuge offers a well-balanced combination of compact design, a wide range of applications and reliable performance. From demanding medical examinations to research-oriented work, the device covers a wide range of possible applications. The extensive rotor options, flexible programme control and high safety standards ensure convenient and efficient operation. With this pioneering laboratory centrifuge, users save valuable time and achieve consistent, reproducible results in almost every routine.


Dimensions (H x W x D) (centrifuges): 271 x 370 x 427 mm365 x 323 x 540 mm365 x 370 x 540 mm
Acceleration-, Deceleration curve: 10
Display (centrifuges): LCD with backlight
Speed max.: 6000 rpm
Speed min.: 200 rpm
Speed range (centrifuges): 200 - 6000 rpm
Field of application (centrifuges): Analytical laboratoriesBlood banksForensic laboratoriesClinical laboratoriesHospitals
Noise level at max. speed: 56 dB (A)
Weight approx. (centrifuges): 14,2 kg
Capacity/capacity max.: 6 x 50 ml
Power consumption (centrifuges): 70 W
Programmes (centrifuges): 99
RCF max.: 4427 xg
Rotor type: angle rotorswing-out rotor
Safety (centrifuges): CEFCClid lock
Time setting range: 10 sec - 99h 59min 59seccontinuousQuickspin
Centrifuge type: universal centrifuge
OHAUS multifunctional centrifuge
Frontier 5000 Series Multi IVD
FC5706P FC5706P+R77 FC5706P+R78 FC5706P+R97
Maximum load (rotor) 6 x 50 ml 6 x 50 ml 6 x 50 ml 6 x 50 ml
Maximum relative centrifugal force 4427 g 4427 g 4427 g 4427 g
Net weight 14.2 kg 14.2 kg 14.2 kg 14.2 kg
Speed range 200 rpm - 6000 rpm 200 rpm - 6000 rpm 200 rpm - 6000 rpm 200 rpm - 6000 rpm
Dimensions LxHxW (mm) 427 x 271 x 370 540 x 365 x 370 540 x 365 x 323 540 x 365 x 370
Lid lock Construction data Construction data Construction data Design data
Power consumption 70 W 70 W 70 W 70 W
Display LCD with backlight LCD with backlight LCD with backlight LCD with backlight
Rotor detection method Manual Manual Manual Manual
Operating environment 5°C to 35°C,
80% relative humidity,
non-condensing
5°C to 35°C,
80% relative humidity,
non-condensing
5°C to 35°C,
80% relative humidity,
non-condensing
5°C to 35°C,
80% relative humidity,
non-condensing
Programme memory 99 99 99 99
Operating time Continous; 10 sec to 99 h 59 min 59 sec; Quickspin Continous; 10 sec to 99 h 59 min 59 sec; Quickspin Continous; 10 sec to 99 h 59 min 59 sec; Quickspin Continous; 10 sec to 99 h 59 min 59 sec; Quickspin
Cooling range Not applicable Not applicable Not applicable Not applicable
Rotor compatibility Angled rotor 12 x 15 ml RB/FA ID; swing-out rotor, 6 x 5 ml RB;
Angled rotor, 6 x 50 ml RB/FA; swing-out rotor, 4 x 10 ml;
Angle rotor, 18 x 1.5/2.0 ml
Angle rotor 12 x 15 ml RB/FA ID; swing-out rotor, 6 x 5 ml RB;
Angle rotor, 6 x 50 ml RB/FA; swing-out rotor, 4 x 10 ml;
Angle rotor, 18 x 1.5/2.0 ml
Angle rotor 12 x 15 ml RB/FA ID; swing-out rotor, 6 x 5 ml RB;
Angle rotor, 6 x 50 ml RB/FA; swing-out rotor, 4 x 10 ml;
Angle rotor, 18 x 1.5/2.0 ml
Angle rotor 12 x 15 ml RB/FA ID; swing-out rotor, 6 x 5 ml RB;
Angle rotor, 6 x 50 ml RB/FA; swing-out rotor, 4 x 10 ml;
Angle rotor, 18 x 1.5/2.0 ml
Noise level ≤ 56 ± 2 dB(A) ≤ 56 ± 2 dB(A) ≤ 56 ± 2 dB(A) ≤ 56 ± 2 dB(A)
Deceleration gearbox 10 10 10 10
Safety certification CE (EU 2017/746) - For more information on intended use and
intended use and contraindications
please refer to the instructions for use; FCC
CE (EU 2017/746) - For more information on the intended use and
intended use and contraindications
please refer to the instructions for use; FCC
CE (EU 2017/746) - For more information on the intended use and
intended use and contraindications
please refer to the instructions for use; FCC
CE (EU 2017/746) - For more information on the intended use and
intended use and contraindications
please refer to the instructions for use; FCC
Accelerator gear 10 10 10 10
Pre-cooling time Not applicable Not applicable Not applicable Not applicable
Power supply Mains adapter (included) Mains adapter (included) Mains adapter (included) Mains adapter (included)
Information on product safety
Manufacturer information:
OHAUS Europe GmbH
Heuwinkelstrasse 3
8606 Nänikon, Schweiz
[email protected]
Responsible person:
Mr. Schuldt
0049 30 403 667 940
[email protected]