BINDER CO2 Incubator CB 170

Item number: BIND_6095!

EAN: 4064343018104

Category: BINDER

Manufacturer: Binder

starting from 10.694,00 €

Manufacturer’s suggested retail price: 10.694,00 €

Excluding 19% VAT. , plus shipping (Sperrgut)

(including 19% VAT. 12.725,85 €)
Modell

There are variations of this item. Please select the variation you wish.


BINDER CO2 Incubator CB 170
CO2 incubators with hot air sterilization and heat sterilizable CO2 sensor

The BINDER CB series CO2 incubator is the premium class among the CO2 incubators. It is suitable for all sensitive incubation applications and ensures optimal cell growth.
A BINDER CB series CO2 incubator can perform complex cultivation experiments as well as specific enviromental conditions.

Important characteristics
  • Temperature range: ambient temperature plus 4 °C to 60 °C
  • Humidity range: 90 to 95% RH
  • CO2 control range: 0 to 20 vol% CO2
  • O2 control range: 0.2 to 20 vol% O2 for versions with O2 control
  • Alternative O2 control range: 10 to 95 vol% O2, option for versions with O2 control
  • Tried-and-tested anti-contamination concept with 180 °C hot air sterilization
  • Hot-air sterilizable CO2 sensor with single-beam infrared technology
  • CO2 gas-mixing jet with Venturi effect
  • Intuitive touchscreen controller
  • Internal data recording, can be read out in open format via USB interface
  • Optimized double-pan humidification system with condensation protection
  • 170 liters of extra space in the interior while maintaining the same footprint
  • Stacking height of just 1.80 m for easy use of the top unit
  • Fail-safe CO2 automatic diagnosis system for protecting the pH of cell cultures
  • DuoDoor system: Unit door and glass door can be opened with one handle
  • Lockable door handle
  • Computer interface: Ethernet
  • Zero-voltage alarm contact
  • Tightly sealed inner door made of tempered safety glass
  • 3 perforated shelves, stainless steel
  • Units are stackable with stacking adapter
The CB 170 is available in the following versions:
CB170-230V Standard
CB170-230V-O with O2 control 0.2-20%
CB170-230V-F with active humidification
CB170-230V-OF with O2 control 0.2-20% and active humidification
CB170UL-120V Standard
CB170UL-120V-O with O2 control 0.2-20%
CB170UL-120V-F with active humidification
CB170UL-120V-OF with O2 control 0.2-20% and active humidification

Load max.: 11 - 50 kg
Width outside (incubators,...): 680 mm
Width inside (incubators,...): 560 mm
Maximum temperature (heat): + 60 °C
Height outside (incubators,...): 870 mm
Height inside (incubators,...): 600 mm
Incubator model: CO2 incubator
Interior volume: 101 - 200 l
Depth outside (incubators,...): 715 mm
Depth inside (incubators,...): 505 mm
Lowest temperature (cooling): + 4 °C
Product weight: 95,00 Kg
Dimensions: × × cm
BINDER CO2 Incubator CB 170-230V 1 CB 170-230V-O 1 CB 170-230V-F 1 CB 170-230V-OF 1
Option model
Standard
with O2 control
With active humidification
With O2 control 0.2-20%
and active humidification
Performance Data Temperature
Recovery time after 30 seconds door open at 37 °C [min] 6 6 6 6
Temperature fluctuation at 37 °C [+ K] 0.1 0.1 0.1 0.1
Temperature range 4 °C above ambient temperature to [°C] 60 - - -
Temperature range 6 °C above ambient temperature to [°C] - 60 60 60
Temperature variation at 37 °C [+ K] 0.3 0.4 0.4 0.4
Performance Data Climate
Humidity range [% RH] 90 to 95 90 to 95 90 to 95 50 to 95
CO2-Data
CO2 measurement IR IR IR IR
CO2 range [Vol.-% CO2] 0 to 20 0 to 20 0 to 20 0 to 20
CO2 Recovery time after 30 seconds door open at 5 Vol.-% CO2 [min] 5 5 5 5
O2-Data
O2 control ranges with option: O2 range [Vol.-% O2] - 10 to 95 - 10 to 95
O2 Recovery time after 30 seconds door open at 5 Vol.-% O2 [min] - 10 - 12
Standard O2 control ranges: O2 range [Vol.-% O2] - 0.2 to 20 - 0.2 to 20
Electrical data
Nominal power [kW] 1.4 1.4 1.4 1.4
Phase (Nominal voltage) 1~ 1~ 1~ 1~
Power frequency [Hz] 50/60 50/60 50/60 50/60
Rated Voltage [V] 200 to 240 200 to 240 200 to 240 200 to 240
Unit fuse [A] 10 10 10 10
Doors
Inner doors 1 1 1 1
Unit doors 1 1 1 1
Internal Dimensions
Depth [mm] 505 505 505 505
Height [mm] 600 600 600 600
Width [mm] 560 560 560 560
Measures
Interior volume [L] 170 170 170 170
Load per rack [kg] 10 10 10 10
Net weight of the unit (empty) [kg] 95 95 95 95
permitted load [kg] 30 30 30 30
Wall clearance back [mm] 100 100 100 100
Wall clearance sidewise [mm] 50 50 50 50
Outer dimensions
Depth net [mm] 715 715 715 715
Height net [mm] 870 870 870 870
Width net [mm] 680 680 680 680
Environment-specific data
Energy consumption at 37 °C [Wh/h] 55 55 55 55
Sound-pressure level [dB(A)] 41 41 41 41
Fixtures
Number of shelves (std./max.) 3/6 3/6 3/6 3/6

BINDER CO2 Incubator CB 170UL-120V1 CB 170UL-120V-O1 CB 170UL-120V-F1 CB 170UL-120V-OF1
Option model
Standard
with O2 control
With active humidification
With O2 control 0.2-20%
and active humidification
Performance Data Temperature
Recovery time after 30 seconds door open at 37 °C [min] 6 6 6 6
Temperature fluctuation at 37 °C [+ K] 0.1 0.1 0.1 0.1
Temperature range 4 °C above ambient temperature to [°C] 60 - - -0
Temperature range 6 °C above ambient temperature to [°C] - 60 60 60
Temperature variation at 37 °C [+ K] 0.3 0.4 0.4 0.4
Performance Data Climate
Humidity range [% RH] 90 to 95 90 to 95 50 to 95 50 to 95
CO2-Data
CO2 measurement IR IR IR IR
CO2 range [Vol.-% CO2] 0 to 20 0 to 20 0 to 20 0 to 20
CO2 Recovery time after 30 seconds door open at 5 Vol.-% CO2 [min] 5 5 5 5
O2-Data
O2 control ranges with option: O2 range [Vol.-% O2] - 10 to 95 - 10 to 95
O2 Recovery time after 30 seconds door open at 5 Vol.-% O2 [min] - 10 - 12
Standard O2 control ranges: O2 range [Vol.-% O2] - 0.2 to 20 - 0.2 to 20
Electrical data
Nominal power [kW] 1.4 1.4 1.4 1.4
Phase (Nominal voltage) 1~ 1~ 1~ 1~
Power frequency [Hz] 50/60 50/60 50/60 50/60
Rated Voltage [V] 100 to 120 100 to 120 100 to 120 100 to 120
Unit fuse [A] 16 16 16 16
Doors
Inner doors 1 1 1 1
Unit doors 1 1 1 1
Internal Dimensions
Depth [mm] 505 505 505 505
Height [mm] 600 600 600 600
Width [mm] 560 560 560 560
Measures
Interior volume [L] 170 170 170 170
Load per rack [kg] 10 10 10 10
Net weight of the unit (empty) [kg] 95 95 95 95
permitted load [kg] 30 30 30 30
Wall clearance back [mm] 100 100 100 100
Wall clearance sidewise [mm] 50 50 50 50
Outer dimensions
Depth net [mm] 715 715 715 715
Height net [mm] 870 870 870 870
Width net [mm] 680 680 680 680
Environment-specific data
Energy consumption at 37 °C [Wh/h] 55 55 55 55
Sound-pressure level [dB(A)] 41 41 41 41
Fixtures
Number of shelves (std./max.) 3/6 3/6 3/6 3/6

1 All technical data is specified for unloaded units with standard equipment at an ambient temperature of +22 °C +3 °C and a power supply voltage fluctuation of +10%.
The temperature data is determined to BINDER factory standard following DIN 12880, observing the recommended wall clearances of 10 % of the height, width, and depth of the inner chamber.
All indications are average values, typical for units produced in series.
We reserve the right to change technical specifications at any time.