Model

There are variations of this item. Please select the variation you wish.


BINDER CO2 Incubator CB 260

The BINDER CB is suitable for all sensitive incubation tasks and guarantees best cell growth. Even complex cultivation approaches or individual growth environments under hypoxic conditions are no problem for this BINDER incubator due to its extensive range of options and accessories.

Advantages
  • Maximum usable space with minimum footprint and good operability
  • Minimal risk of contamination due to uncompromising hot air sterilization
  • Fan-free, easy to clean hygienic interior without fixtures
  • Stable pH values due to drift-free CO2 IR sensor technology
  • Low medium atomization due to high humidity and fast recovery time
Key features
  • Temperature range: from +5 °C above ambient temperature to +60 °C
  • Humidity range: up to 95 % r.h.
  • O2 control range: 0.2-20 vol% O2 for model variants with O2 control
  • Auto sterilization by hot air at +180 °C
  • Double shell humidification system with dew protection
  • CO2 gas mixing nozzle with Venturi effect
  • Hot air sterilizable CO2 sensor with infrared technology
  • Intuitively operated touch screen controller
  • Internal data logger, measured values can be read out in open format via USB
  • Lockable door handle
  • Tightly closing inner door made of safety glass (ESG)
  • Seamless stainless steel inner boiler
  • 3 perforated stainless steel shelves
  • Units stackable with stacking adapter
  • Fault diagnosis system with optical and acoustic alarm
  • Computer interface: Ethernet
  • Potential-free alarm contact
Optional equipment
  • Model variants with O2 control range 0.2-20 vol% O2 or 10-95 vol% O2
  • Model variants with humidity control range: 50-95 % r.h. through active humidification
  • Comfortable water supply with reusable tubular bags, prefilled one-litre water bottle or water canister set with magnetic holder, for model variants with active humidification
  • Multi-partitioned glass doors with special drawers for spatial separation of the experiments
  • Stacking adapter for safe and space-saving installation
  • Gas bottle changer for connecting two gas bottles to up to two incubators
  • CO2 shaker with corrosion-resistant components in stainless steel housing
  • Multi Management Software APT-COM - Manage, record and document device parameters
  • Services - comprehensive services ensure correct device function
Please select a model.

Load max.: 11 - 50 kg
Width outside (incubators,...): 740 mm
Width inside (incubators,...): 620 mm
Maximum temperature (heat): + 60 °C
Height outside (incubators,...): 1020 mm
Height inside (incubators,...): 750 mm
Incubator model: incubatorCO2 incubator
Interior volume: 201 - 300 l
Depth outside (incubators,...): 785 mm
Depth inside (incubators,...): 575 mm
Lowest temperature (cooling): + 5 °C
Product weight: 125,00 Kg
Dimensions: × × cm
BINDER CO2 Incubator CB260 CB260-230V1 CB260-230V-O1 CB260-230V-F1 CB260-230V-OF1 CB260UL-120V1 CB260UL-120V-O1 CB260UL-120V-F1 CB260UL-120V-OF1
Design Standard with O2
control 0.2-20%
with active
humidification
with O2 control 0.2-20%
and active humidification
Standard with O2
control 0.2-20%
with active
humidification
with O2 control 0.2-20%
and active humidification
Item number 9040-0147 9040-0148 9040-0149 9040-0150 9040-0152 9040-0153 9040-0154 9040-0155
General data                
Series CB CB CB CB CB CB CB CB
Performance data Temperature                
Recovery time after 30 s door opening at 37 °C [min] 6 6 6 6 6 6 6 6
Spatial temperature deviation at 37 °C [± K] 0,4 0,4 0,4 0,4 0,4 0,4 0,4 0,4
Temperature range +4 °C above room temperature to 60 60 60 60 60 60 60 60
Temperature range +5 °C above room temperature to 60 60 60 60 60 60 60 60
Temperature deviation over time at 37 °C [± K]. 0,1 0,1 0,1 0,1 0,1 0,1 0,1 0,1
Performance data climate                
Humidity range [% r.h.] 90...95 90…95 90…95 90…95 90…95 90…95 90…95 90…95
CO2 data                
CO2 range [vol. % CO2]. 0…20 0…20 0…20 0…20 0…20 0…20 0…20 0…20
CO2 recovery time after 30 s door opening at 5 vol.% CO2 [min] 5 5 5 5 5 5 5 5
CO2 measurement technology IR IR IR IR IR IR IR IR
O2 data                
O2 recovery time after 30 s door opening at 5 vol.% O2 [min] - 15 - 15 - 15 - 15
O2 control range by option: O2 range [Vol.% O2] - 10…95 - 10…95 - 10…95 - 10…95
O2 control range Standard: O2 range [Vol.% O2] - 0,2…20 - 0,2…20 - 0,2…20 - 0,2…20
Electrical data                
Device fuse [A] 10 10 10 10 16 16 16 16
Rated power [kW] 1,5 1,5 1,5 1,5 1,5 1,5 1,5 1,5
Nominal voltage [V] 200…230 200…230 200…230 200…230 100…120 100…120 100…120 100…120
Mains frequency [Hz] 50/60 50/60 50/60 50/60 50/60 50/60 50/60 50/60
Phase (rated voltage) 1~ 1~ 1~ 1~ 1~ 1~ 1~ 1~
Number of doors                
External doors 1 1 1 1 1 1 1 1
Interior doors 1 1 6 6 1 1 6 6
Housing dimensions without attachments and connections                
Width net [mm] 740 740 740 740 740 740 740 740
Net height [mm] 1020 1020 1020 1020 1020 1020 1020 1020
Net depth [mm] 785 785 785 785 785 785 785 785
Inner dimensions                
Width [mm] 620 620 620 620 620 620 620 620
Height [mm] 750 750 750 750 750 750 750 750
Depth [mm] 575 575 575 575 575 575 575 575
Dimensions                
Net weight of the unit (empty) [kg] 125 125 125 125 125 125 125 125
Interior volume [L] 267 267 267 267 267 267 267 267
Maximum load per slide-in module [kg] 10 10 10 10 10 10 10 10
Maximum total load [kg] 40 40 40 40 40 40 40 40
Rear wall distance [mm] 100 100 100 100 100 100 100 100
Distance to wall [mm] 50 50 50 50 50 50 50 50
Environmentally relevant data                
Energy consumption at 37 °C [Wh/h] 65 65 65 65 65 65 65 65
Sound pressure level [dB(A)]. 41 41 41 41 41 41 41 41
Installations                
Number of slide-in modules (hrs/max.) 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8


1 All technical data apply exclusively to unloaded devices in standard version at an ambient temperature of 22 ±3 °C and a mains voltage fluctuation of ±10 %. The temperature data are determined according to BINDER factory standard and DIN 12880:2007 and are based on the recommended wall distances of 10% of the height, width and depth of the interior. All specifications are typical average values for series devices. We reserve the right to make technical changes.