BINDER CO2 incubator CB-S 170

Item number: BIND_6132

EAN: 4064343271226

Category: Incubators, Drying Cabinets

Manufacturer: Binder

starting from 8.030,00 €

Manufacturer’s suggested retail price: 8.030,00 €

Excluding 19% VAT. , plus shipping (Sperrgut)

(including 19% VAT. 9.555,69 €)
Power supply

There are variations of this item. Please select the variation you wish.


BINDER CO2 incubator CB-S 170

The BINDER CB-S 170 CO2 incubator is a specialised solution for precise cell cultivation and is particularly suitable for demanding applications in research laboratories and in biotechnology. The device provides reliable and constant conditions for optimised cell culture growth. Compared to similar products on the market, it impresses with efficient hot air sterilisation, a fanless interior and a sophisticated anti-contamination concept.

Advanced technologies for safe laboratory processes

This device is characterised by a range of intelligent functions to simplify work in research, development and production. With a hot sterilisation method at 180 °C, the system ensures unique safety and contamination protection. The stable pH environment is reliably maintained thanks to the drift-free infrared CO2 sensor, while an integrated Venturi CO2 gas mixing nozzle supports homogeneous CO2 distribution in the interior.

The inner chamber is made of seamless stainless steel, which makes it easy to clean. In addition, the fanless design eliminates unnecessary air currents, which in turn reduces soiling in the interior. An integrated PID controller with a clear LCD display facilitates operation, while a data logger outputs relevant measured values to a USB stick. In addition, troubleshooting is simplified by a diagnostic system with visual and audible alarms.

Technical highlights at a glance

The following are the key performance data that make the incubator a robust, versatile and economical solution:

  • Temperature range: +6 °C above room temperature to 50 °C
  • Recovery time after 30 s door opening at 37 °C: 6 minutes
  • Humidity range: 90 to 95 % r.h.
  • CO2 range: 0 to 20 % by volume
  • IR CO2 sensor and Venturi gas mixing nozzle for pH-stable cultivation conditions
  • Internal volume: 170 litres
  • Sound pressure level: 41 dB(A)

The appliance is available in versions for 200-230 V and 100-120 V and fulfils the usual standards and directives, including CE marking. Thanks to a rated output of 1.3 kW, it is energy-efficient even in continuous operation; it also works particularly economically thanks to the customised heating and humidification system.

The interior allows for up to six shelves, which means that a large number of samples can be cultivated at the same time. The external dimensions (width 680 mm, height 870 mm, depth 715 mm) allow installation in many standard laboratory furniture. The high-quality workmanship ensures a long service life, while the stainless steel construction effectively reduces corrosion and contamination.

Examples of use

- Production and maintenance of a wide variety of cell lines in biotechnology laboratories
- Research on proteins, enzymes and antibodies in academia
- Pharmaceutical product development with a focus on in vitro drug testing
- Microbiological testing of yeasts and bacteria for diagnostics and quality control

FAQs

How does hot air sterilisation at 180 °C work?

In hot air sterilisation, the interior is heated to 180 °C. This temperature thoroughly disinfects all surfaces and minimises the risk of contamination for cultures.

Why is a fanless interior advantageous?

The fanless design prevents unwanted air turbulence and thus reduces the risk of particle carryover, providing optimal contamination protection for the samples.

How to control the CO2 content

The built-in infrared CO2 measuring system reacts drift-free and ensures constant CO2 concentrations. The desired value can be set and constantly monitored via the PID controller.

Which certifications are available

The device fulfils the current laboratory standards and has a CE mark. It therefore complies with European safety and quality guidelines.

How quickly does the CO2 concentration stabilise after door openings?

The incubator only needs around five minutes to restore the set CO2 level, even with short-term fluctuations caused by open doors.

Can the interior be flexibly customised for different areas of use?

Yes, several slide-in units can be used. Each drawer can hold up to 10 kg, which provides sufficient space for different sample containers.

Is it easy to operate

Thanks to the clear LCD display and logically structured menus, the system can be controlled intuitively. In addition, an audible and visual alarm informs you of any deviations.

Conclusion

The BINDER CB-S 170 CO2 incubator impresses as a reliable incubator for laboratory environments that place the highest demands on contamination protection, pH stability and user-friendliness. The combination of hot air sterilisation, durable stainless steel construction and innovative CO2 measuring system ensures optimum cell growth conditions. This makes it ideal for demanding research and routine applications in the biotech and pharmaceutical sectors. At the same time, the device impresses with its economical operation, clear control of all parameters and wide range of applications in everyday laboratory work.


Load max.: 11 - 50 kg
Width outside (incubators,...): 680 mm
Width inside (incubators,...): 560 mm
Maximum temperature (heat): + 50 °C
Height outside (incubators,...): 870 mm
Height inside (incubators,...): 600 mm
Incubator model: CO2 incubatorincubator
Interior volume: 101 - 200 l
Maximum power: 1,3 kW
Cabinet type: incubator
Depth outside (incubators,...): 715 mm
Depth inside (incubators,...): 505 mm
Shipping weight: 96,00 Kg
Product weight: 96,00 Kg
Dimensions: × × cm
BINDER CO2 incubator CB-S 170-230V CB-S 170-230V-D CB-S 170UL-120V CB-S 170UL-120V-D
Version standard with feed-through 30 mm left Standard version with feed-through 30 mm left
Performance data Temperature
Temperature range +6 °C above room temperature up to 50 °C +6 °C above room temperature up to 50 °C +6 °C above room temperature up to 50 °C +6 °C above room temperature up to 50 °C
Spatial temperature deviation at 37 °C 0,3 ± K 0,3 ± K 0,3 ± K 0,3 ± K
Temporal temperature deviation at 37 °C 0,1 ± K 0,1 ± K 0,1 ± K 0,1 ± K
Recovery time after 30 s door opening at 37 °C 6 min 6 min 6 min 6 min
Performance data Climate
Humidity range 90 ...95 % r.h. 90 ...95 % r.h. 90 ...95 % r.h. 90 ...95 % r.h.
Gas data
CO2 range 0 ...20 vol.% CO2 0 ...20 vol.% CO2 0 ...20 vol.% CO2 0 ...20 vol.% CO2
CO2 measurement technology IR IR IR IR
CO2 recovery time after 30 s door opening at 5 vol.-% CO2 5 min 5 min 5 min 5 min 5 min
Electrical data
Rated voltage 200...230 V 200...230 V 100...120 V 100...120 V
Mains frequency 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz
Rated power 1.3 kW 1.3 kW 1.3 kW 1.3 kW
Device fuse 10,0 A 10,0 A 16,0 A 16,0 A
Phase (rated voltage) 1~ 1~ 1~ 1~
Dimensions and weights
Interior volume 170 l 170 l 170 l 170 l
Net appliance weight (empty) 96 kg 96 kg 96 kg 96 kg
Maximum load per shelf 10 kg 10 kg 10 kg 10 kg
Maximum total load 30 kg 30 kg 30 kg 30 kg
Rear wall clearance 100 mm 100 mm 100 mm 100 mm
Lateral wall clearance 50 mm 50 mm 50 mm 50 mm
Enclosure dimensions without attachments and connections
Net width 680 mm 680 mm 680 mm 680 mm
Net height 870 mm 870 mm 870 mm 870 mm
Net depth 715 mm 715 mm 715 mm 715 mm
Interior dimensions
Interior width 560 mm 560 mm 560 mm 560 mm
Interior height 600 mm 600 mm 600 mm 600 mm
Interior depth 505 mm 505 mm 505 mm 505 mm
Interior doors 1 1 1 1
Exterior doors 1 1 1 1
Environmentally relevant data
Sound pressure level 41 dB(A) 41 dB(A) 41 dB(A) 41 dB(A)
Energy consumption at 37 °C 45 Wh/h 45 Wh/h 45 Wh/h 45 Wh/h
Built-in units
Number of plug-in units (hr./max.) 2/6 2/6 2/6 2/6
Information on product safety
Manufacturer information:
Binder GmbH
Im Mittleren Ösch 5
78532 Tuttlingen, Deutschland
[email protected]
Responsible person:
Mr. Schuldt
0049 30 403 667 940
[email protected]