BINDER Cooled incubator KB 400 (E5.1)
Item number: BIND_6044!
EAN: 4064343304955
Manufacturer:
Binder
Now only
9.262,88 €
Manufacturers suggested retail price:
9.750,40 €
Excluding 19% VAT. ,
plus
(Sperrgut)
(including 19% VAT. 11.022,83 €)
BINDER Cooled incubator KB 400 (E5.1). ProfiLab24.com laboratory supplies and laboratory equipment with top advice and 24H service
BINDER Cooled incubator KB 400 (E5.1) with mechanical convectionThe most versatile among the cooled incubators for microorganisms: The BINDER KB series cooled incubator controls temperature ranges of -5 °C to 100 °C. With its comprehensive program functions, this cooled incubator offers a wide range of capabilities and delivers reproducible test results.
- Electronically controlled APT.lineTM preheating chamber and patented DCTTM refrigeration system assuring temperature accuracy and reproducible results in both heating and cooling situations
- Temperature range -5 °C to 100 °C
- MP controller with 2 programs with 10 sections each, alternatively switchable to 1 program with 20 sections
- Integrated week program timer with real-time function
- Adjustable ramp function via program editor
- Digital temperature setting with an accuracy of a tenth of a degree
- Adjustable fan speed
- Elapsed time indicator
- Independent adjustable temperature safety device class 3.1, providing full protection against chamber over-temperature, with visual and audible temperature alarm
- Inner glass doors
- RS 422 interface for communication software APT-COMTM DataControlSystem
- Adjustable intervals for printer
- 4 castors (2 with brakes)
- Access port with silicone plug Ø 30 mm, left side
- 2 stainless steel racks
- BINDER test confirmation
Load max.:
|
101 - 150 kg
|
Width outside (incubators,...):
|
930 mm
|
Width inside (incubators,...):
|
650 mm
|
Maximum temperature (heat):
|
+ 100 °C
|
Height outside (incubators,...):
|
1945 mm
|
Height inside (incubators,...):
|
1270 mm
|
Incubator model:
|
cooling incubator
|
Interior volume:
|
301 - 400 l
|
Cabinet type:
|
incubator
|
Depth outside (incubators,...):
|
800 mm
|
Depth inside (incubators,...):
|
485 mm
|
Lowest temperature (cooling):
|
- 5 °C
|
BINDER cooling incubator |
KB 400 (E5.1) |
Exterior dimensions |
|
Width (mm) |
930 |
Height (incl. casters) (mm) |
1945 |
Depth (plus door handle, I-panel and connection 100 mm) (mm) |
800 |
Wall clearance, rear (mm) |
100 |
Wall clearance, side (mm) |
100 |
Number of doors (ea.) |
1 |
Inner glass door(s) (ea.) |
1 |
Interior dimensions |
|
Width (mm) |
650 |
Height (mm) |
1270 |
Depth (mm) |
485 |
Interior volume (l) |
400 |
Racks (number standard/max.) |
2 / 15 |
Load per rack (kg) |
30 |
Permitted total load (kg) |
120 |
Weight (empty) (kg) |
220 |
Temperature data |
|
Temperature range (°C) 1) |
-5 - 100 |
Temperature variation max. (± K) at 4 °C (± K) at 25 °C (± K) at 37 °C (± K) |
0,6 0,4 0,2 0,3 |
Temperature fluctuation max. (± K) |
0,1 |
Recovery time after door was opened for 30 sec 2) at 4 °C (± K) at 37 °C (± K) |
14 3 |
Electrical data |
|
IP protection class acc. to EN 60529 |
IP 20 |
Voltage (±10 %) 50/60 Hz (V) 50/60 Hz (V) |
200-240 V 1N ~ 100-120 V 1N ~ |
Nominal power at 240 V (kW) |
1,4 |
Energy consumption 3) at 37 °C (W) |
420 |
Noise level (dB (A)) |
53 |
1) Lower values are valid up to an ambient temperature of max. 25 °C.
2) To 98% of the set value
3) These values can be used for dimensioning air condition systems.
The useable interior height depends on the position of racks.
All technical data are specified for units with standard equipment at an ambient temperature of 25 °C and a line voltage fluctuation of ±10%. The temperature data is determined in accordance to factory standard following DIN 12880, respecting the recommended wall clearances of 10% of the height, width and depth of the inner chamber. All figures are typical average values for series devices. We reserve the right to alter technical specifications at any time.