BINDER E 28 Heating oven with temperature safety device 230 V 1~ 50/60 Hz
With a BINDER E series heating oven, you obtain a reliable and powerful unit in a solid configuration at a very attractive price. This heating oven is preferred for tasks in basic research, as well as in human and veterinary medicine.
  • Temperature range 60 °C (140 °F) to 230 °C (446 °F)
  • Robust, space-saving small unit with hydraulic-mechanical control and adjustable ventilation
  • Hydro-mechanical thermostat
  • Timer 0 to 120 min
  • Optional independent temperature safety device class 1 (DIN 12880)
  • 2 chrome-plated racks included
  • Units are stackable
  • BINDER test confirmation

Load max.: 11 - 50 kg
Width outside (incubators,...): 580 mm
Width inside (incubators,...): 400 mm
Maximum temperature (heat): + 230 °C
Height outside (incubators,...): 402 mm
Height inside (incubators,...): 280 mm
Interior volume: up to 50 l
Cabinet type: heating oven
Depth outside (incubators,...): 425 mm
Depth inside (incubators,...): 250 mm
Shipping weight: 27,00 Kg
Product weight: 22,00 Kg
Dimensions: × × cm
BINDER Heating oven E 28
Exterior dimensions
Width (mm) 580
Height (incl. feet) (mm) 405
Depth (mm) 425
Plus door handle, I-panel, connection (mm) 50
Wall clearance, rear (mm) 100
Wall clearance, side (mm) 160
Number of doors (ea.) 1
Interior dimensions
Width (mm) 400
Height (mm) 280
Depth (mm) 250
Interior volume (l) 28
Racks (number standard/max.) 2 / 4
Load per rack (kg) 10
Permitted total load (kg) 25
Weight (empty) (kg) 22
Temperature data
Temperature range approx. 5 °C above ambient temperature to (°C) 60 - 230
Temperature variation at 70 °C (± K) 1) 3
Temperature fluctuation at 70 °C (± K) 1,5
Warm-up time 2)
at 70 °C (min)
at 150 °C (min)

28
36
Recovery time after doors were open for 30 sec. 2)
at 70 °C (min)
at 150 °C (min)

11
19
Ventilation data
Ventilation at 70 °C (x/h) 30
Electrical data
IP protection class acc. to EN 60529 IP 20
Voltage (± 10%) 50 / 60 Hz (V) 230
Nominal power (kW) 0,8

1)without a viewing window
2)to 98% of the set value

All technical data are specified for units with standard equipment at an ambient temperature of 25 °C and a line voltage fluctuation of ±10%. The temperature data is determined in accordance to factory standard following DIN 12880, respecting the recommended wall clearances of 10% of the height, width and depth of the inner chamber. All figures are typical average values for series devices. We reserve the right to alter technical specifications at any time.