BINDER BD 720 incubator
The BINDER BD 720 incubator is a state-of-the-art incubator that has been specially developed for laboratory and medical applications. With its large interior, precise temperature control and a host of technical innovations, it is indispensable for the cultivation of microorganisms, cell cultures, insect and animal cultures, as well as for demanding incubation and development processes. Its consistent design for reliability, safety and ease of use makes it the first choice for professional users who demand the highest standards of consistent incubation conditions.
Performance features and technical highlights
The BD 720 impresses with its robust, durable construction and a comprehensive range of features that are specifically tailored to the requirements of research, development and routine analysis. For a quick overview of the most important technical data:
- Temperature range: from 5 °C to ambient temperature to 100 °C
- Interior volume: 720 litres, external dimensions (WxHxD): 1235 x 1530 x 865 mm
- Precise temperature stability: ±0.5 K spatially, ±0.1 K temporally at 37 °C
- Maximum total load: 120 kg (up to 45 kg per shelf, 2/15 shelves as standard/maximum)
- Energy consumption at 37 °C: only 80 W, rated power: 1.25 kW, operating voltage: 230 V (alternatively 115 V)
- IP protection class: IP 20 according to EN 60529, hot air sterilisability according to DIN 58947
Users also benefit from other special technical features:
The BINDER BD 720 incubator offers an innovative VENTAIR air jacket system for homogeneous temperature distribution without disruptive air currents in the sample chamber. The Permadry system with double-tray humidification and dehumidification ensures a defined condensation point, protecting cultures from drying out and contamination. The ANTI.PLENUM design minimises contamination-critical areas, while a drift-free CO? infrared absorption measurement system (depending on model) ensures maximum measurement accuracy and long-term stability.
The control unit allows all relevant process parameters to be read via a modern controller with simultaneous data monitoring. The graphical display and an electronic line recorder facilitate evaluation. Safety-related functions such as an electronic fault self-diagnosis system and visual and acoustic temperature alarms ensure reliable operation. In addition, there is a potential-free changeover contact for central monitoring. The system can be connected to the APT-COM DataControl software for comprehensive documentation and remote monitoring via the Ethernet interface. The standard-compliant hot air sterilisation of the entire chamber is another unique selling point and guarantees maximum hygiene during every incubation cycle.
Certifications and standards
For highly sensitive laboratory applications, the incubator complies with the following standards:
- DIN 58947 for hot air sterilisation at 180 °C
- EN 60529 (protection class IP 20)
- Temperature control and measurement accuracy according to factory standard based on DIN 12880
This ensures that both safety and quality requirements for medical and scientific equipment are reliably met.
Application examples in laboratories and medicine
As a versatile incubator, the BD 720 is particularly suitable for the following tasks:
-
Cultivation of microorganisms: Cultivation and analysis of bacterial strains, moulds, yeasts and other microorganisms in microbiological laboratories.
-
Rearing insect and animal cultures: Stable, controlled conditions for research and development work on Drosophila melanogaster, zebrafish, mites and other small laboratory animals.
-
Cell culture and cell growth analyses: Monitoring of proliferation, differentiation and vitality of eukaryotic cell lines for molecular biology and pharmaceutical studies. Frequently used for cell lines such as CHO, HeLa, or SH-SY5Y.
-
Incubation and development processes: Embryonic development, germination of plant seeds, in vitro fertilisation or incubation of immunological assays.
The large interior volume allows both individual tests and large-volume experiments to be carried out efficiently.
FAQs
How is the temperature in the incubator regulated?
Temperature regulation is microprocessor-controlled and offers a deviation of only ±0.5 K spatially and ±0.1 K temporally, ideal for sensitive samples.
Can the interior be completely sterilised?
Yes, standard-compliant hot air sterilisation at 18 °C in accordance with DIN 58947 enables comprehensive decontamination of the entire interior and all removable components.
What is the maximum number of grid inserts that can be used?
Two grid inserts are included as standard, and a total of up to 15 grid inserts can be fitted, with a maximum load of 45 kg per grid.
What options are available for remote monitoring and documentation?
The Ethernet interface and compatibility with APT-COM DataControl software enable professional remote monitoring, data recording and event-driven alarms.
Are sensor-based safety systems available?
An electronic fault self-diagnosis system and temperature selectors with visual and audible alarms ensure maximum operational safety.
Can the incubator use different voltage systems?
Operation is possible with 230 V (50/60 Hz) and optionally with 115 V (60 Hz).
How is contamination prevented in the incubator?
The special ANTI.PLENUM design and the Permadry double tray humidification system reduce areas at risk of contamination and ensure hygienically safe incubation conditions.
Conclusion
The BD 720 combines maximum technical precision, optimum safety features and intelligent operability in a large-volume, versatile incubator. Whether for demanding microbiological, medical or biotechnological applications, this incubator sets standards in terms of reliability, hygiene and ease of use. Its innovative features and flexibility make it the ideal choice for any professional laboratory environment.