BINDER MK 115 (E3.1) Environmental simulation chamber for cyclical temperature - ProfiLab24 GmbH
99
100
24
4
stars -
Professional service
Customer
Young team with a lot of ambition and quick answers to all questions. We needed a complete laboratory equipment for our new location. The team of Profiab24 has arranged everything.
BINDER MK 115 (E3.1) Environmental simulation chamber for cyclical temperature
Item number: BIND_6062!
EAN: 4064343302302
Manufacturer:
Binder
23.580,00 €
Manufacturers suggested retail price:
23.580,00 €
Excluding 19% VAT. ,
plus
(Sperrgut)
(including 19% VAT. 28.060,19 €)
BINDER MK 115 (E3.1) Environmental simulation chamber for cyclical temperature. Order online at ProfiLab24 .com with top advice and 24/7 service. Fast delivery. Secure payment.
BINDER MK 115 (E3.1) Environmental simulation chamber for cyclical temperature
The BINDER environmental simulation chamber of the MK series is suitable for heat or cold testing between -40 °C and 180 °C. The APT.line
TM preheating chamber technology uniquely simulates a natural environment. For cyclical temperature testing, this environmental simulation chamber is a smart alternative to complex individual solutions.
- Electronically controlled APT.lineTM preheating chamber assuring temperature accuracy and reproducible results
- Temperature range of -40 °C to 180 °C
- MCS controller with 25 storable programs of 100 sections each for a maximum of 500 program segments
- User friendly LCD screen
- Easy-to-read menu guide
- Integrated electronic chart recorder
- Variety of options for the graphic display of process parameters
- Real time clock
- Adjustable ramp function via program editor
- Access port Ø 80 mm, top
- Heated viewing window with LED interior lighting
- Temperature safety device class 2 (DIN 12880) with visual and audible temperature alarm
- RS 422 interface for communication software APT-COMTM DataControlSystem
- 1 stainless steel rack
- BINDER test confirmation
- BINDER Communication software APT-COMTM 3 Basic Edition
Load max.:
|
51 - 100 kg
|
Width outside (incubators,...):
|
1000 mm
|
Width inside (incubators,...):
|
600 mm
|
Maximum temperature (heat):
|
+ 180 °C
|
Height outside (incubators,...):
|
1725 mm
|
Height inside (incubators,...):
|
480 mm
|
Interior volume:
|
101 - 200 l
|
Cabinet type:
|
environmental simulation chamber
|
Depth outside (incubators,...):
|
915 mm
|
Depth inside (incubators,...):
|
400 mm
|
Lowest temperature (cooling):
|
- 40 °C
|
Product weight: |
260,00 Kg |
Dimensions: |
× × cm |
BINDER Environmental simulation chamber |
MK 115 (E3.1) |
Exterior dimensions |
|
Width (incl. 80 mm access port with plug) (mm) |
1000 |
Height (incl. casters) (mm) |
1725 |
Depth (incl. door handle, I-triangle, connection 55 mm) (mm) |
915 |
Wall clearance, side (mm) |
200 |
Wall clearance, rear (mm) |
300 |
Viewing window width (mm) |
288 |
Viewing window height (mm) |
222 |
Number of doors (ea.) |
1 |
Interior dimensions |
|
Width (mm) |
600 |
Height (mm) |
480 |
Depth (mm) |
400 |
Interior volume (l) |
115 |
Shelves (number standard/max.) |
1 / 4 |
Load per shelf (kg) |
30 |
Permitted total load (kg) |
60 |
Weight (empty) (kg) |
260 |
Temperature data |
|
Temperature range (°C) |
-40 - 180 |
Temperature variation (± K) |
0,1 - 2,0 |
Temperature fluctuation (± K) |
0,1 - 0,5 |
Mean warm-up rate acc. to factory standard (°C/min.) -40 °C to 180 °C |
5,3 |
Mean cooling rate acc. factory standard (°C/min.) 180 °C to -40 °C |
5,0 |
Heat compensation, max. (W) |
2000 |
Electrical data |
|
IP protection class acc. to EN 50529 |
IP 20 |
Voltage (±10 %) 50 Hz (V) |
400, 3 N ~ |
Nominal power (kW) |
3,5 |
Energy consumption at 20 °C (W) 1)
|
650 |
Noise level (approx. dB(A)) |
62 |
1) These values can be used for dimensioning air condition systems.
All technical data are specified for units with standard equipment at an ambient temperature of 25 °C and a line voltage fluctuation of ±10%. The temperature data is determined in accordance to factory standard following DIN 12880, respecting the recommended wall clearances of 10% of the height, width and depth of the inner chamber. All figures are typical average values for series devices. We reserve the right to alter technical specifications at any time.