Memmert climatic chamber ICHeco
Climatic chamber for stability testing according to ICH - WHO - EMA - ASEAN - GMP - GLP - GCCP.

Climatic chamber for stability testing according to ICH and GMP. Climate-friendly and
powerful: The ICHeco climatic chamber for stability testing of pharmaceuticals, cosmetics or foodstuffs works with climate-friendly CO2 (R744) as refrigerant. Memmert is thus introducing the environmentally friendly future of compressor-cooled temperature control ovens. In addition, the ICHeco scores points with its unique homogeneity of temperature and humidity. An air jacket around the hermetically sealed working chamber allows heat to be introduced into the climatic chamber quickly and over a large area on four sides. Icing of the cooling unit as well as drying out of samples are successfully avoided.
  • Digitally controlled, active humidification and dehumidification 10 to 80% rh
  • Temperature range -10 °C to +60 °C (models ICHeco / ICH), 0 °C to +60 °C (models ICHeco L / ICH L), +10 °C to +50 °C (models ICH C)
  • 1 model variant - TwinDISPLAY
  • Double doors as standard: Prevention of contamination and temperature drop or rise and at the same time optimal view of the product to be tempered through full-surface interior glass doors
Stability testing in the climatic chamber according to ICH Guidelines Q1B, Option 2 (photostability) In the ICHeco L climatic
chamber
, an illumination unit can be used to test according to ICH Guidelines Q1B, Option 2 (photostability). The light source is a fluorescent lamp with cold white light (daylight: light colour 865, 6,500 K) and UV radiation in the spectral range 320 to 400 nm. Daylight and UV light correspond to standard light D65.

Controlled CO2 supply in the ICH climatic chamber The compact ICH C climatic chamber offers ideal conditions
especially for testing building materials and concrete. Thanks to the electronic CO2 control with automatic zero setting (NDIR measuring system) and an adjustment range from 0 to 10%, reliable long-term tests for determining the carbonation depth in concrete can be carried out without space-, energy- and cost-intensive test chambers.

Climate-friendly refrigerant CO2 ensures better cooling performance The ICHeco climatic
chamber is powerful and environmentally friendly. Compared to units with R134a refrigerant, it scores points with faster changeover speeds during cooling. Of course, the Memmert climatic chambers ICH / ICH L / ICH C with the refrigerant R134a will continue to be available in parallel.

A Memmert climatic chamber ICHeco offers unique advantages
  • CO2 refrigerant (R744) is climate friendly
  • user-friendly, intuitive operating concept
  • Temperature and humidity ramps programmable via AtmoCONTROL software
  • Air exchange rates and air flap position electronically controllable
  • almost exclusive use of high-quality, corrosion-resistant and easy-to-clean stainless steel for the interior and exterior housing
  • various possibilities for programming and documentation with the help of interfaces, integrated data logger and AtmoCONTROL software
  • Worldwide 3 years manufacturer warranty
Standard devices are safety-tested and bear the signs: CE, EAC

Please select a model.

Load max.: 101 - 150 kg151 - 200 kg
Width outside (incubators,...): 745 mm824 mm1224 mm
Width inside (incubators,...): 560 mm640 mm1040 mm
Maximum temperature (heat): + 60 °C
Height outside (incubators,...): 1233 mm1552 mm1950 mm
Height inside (incubators,...): 480 mm800 mm1200 mm
Interior volume: 101 - 200 l201 - 300 l701 - 800 l
Cabinet type: climate chamber
Depth outside (incubators,...): 585 mm685 mm785 mm
Depth inside (incubators,...): 400 mm500 mm600 mm
Lowest temperature (cooling): - 10 °C0 °C
Memmert climatic chamber ICHeco,
model size
110
260
750
Stainless steel interior
Volume approx. (l) 108 256 749
Width (mm) 560 640 1040
Height (mm) 480 800 1200
Depth (mm)
(minus 33 mm for fan)
400
500
600
Max. Number of grates/perforated plates 5 9 14
Max. load per grating / perforated plate (kg) 20 20 30
Max. load per unit (kg) 150 200 200
Max. load per slide-in drip tray (kg) 3 4 8
Max. load per bottom drip tray (kg) 3 4 8
Structured stainless steel housing
Width (mm) 745 824 1224
Height (with rollers) (mm) 1233 1552 1950
Depth (mm) (without door handle), door handle + 56 mm 585 685 785
Standard accessories
Stainless steel gratings, electropolished (quantity) 2 2 2
Feed-through at the rear, 40 mm inner diameter, moisture-proof
, with silicone sealing plug
yes
yes
yes
Water canister including connection hose yes yes yes
Standard factory calibration
certificate (measuring point in the middle of the useful space) (°C)
+10 °C, +37 °C and
+30 °C with 60% rh
like 110
like 110
Temperature
Working temperature range without humidity ICHeco
(not suitable for permanent storage at minus
temperatures. During continuous operation icing of the
glass door may occur) (°C)
-10 to +60


like 110


like 110


Working temperature range ICHeco /ICHeco L
with humidity and/or light (°C)
-10 to +60
like 110
like 110
Working temperature range ICHeco L without humidity (°C) 0 to +60 like 110 like 110
Setting temperature range ICHeco (°C) -10 to +60 like 110 like 110
Setting temperature range ICHeco L (°C) 0 to +60 like 110 like 110
Setting accuracy (°C)
Humidity
Setting range humidity (% rh) 10 to 80 like 110 like 110
Setting accuracy (% rh) 0,5 0,5 0,5
Light
Illumination unit (only for model ICHeco L) according to
ICH Q1B, option 2; separately switchable via controller, one
slot; number of fluorescent lamps with cold white light (
size 110: 3, sizes 260/750: 4), light colour 865 6.500 K; number of fluorescent lamps with
UV lamps (all sizes: 2), spectral range 320 to 400 nm; (daylight
and UV light correspond to standard light D65)
yes





yes





yes





Power consumption at 230 V, 50/60 Hz ICHeco approx. (W) 1350 1350 1350
Power consumption at 230 V, 50/60 Hz ICHeco L approx. (W) 1450 1450 1550
Weight
Net weight (kg) 114 165 254