Nabertherm High-Temperature Tube Furnace - ProfiLab24 GmbH
99
100
24
4
stars -
Professional service
Customer
Young team with a lot of ambition and quick answers to all questions. We needed a complete laboratory equipment for our new location. The team of Profiab24 has arranged everything.
Nabertherm High-Temperature Tube Furnace
Item number: NAB_8136
EAN: 4064343081344
Manufacturer:
Nabertherm
starting from
16.093,00 €
Manufacturers suggested retail price:
16.940,00 €
Excluding 19% VAT. ,
plus
(Sperrgut)
(including 19% VAT. 19.150,67 €)
Nabertherm High-Temperature Tube Furnace. ProfiLab24.com laboratory supplies and laboratory equipment with top advice and 24H service
- Model
-
There are variations of this item. Please select the variation you wish.
Nabertherm High-Temperature Tube Furnace, models RHTV 50/150/.. - RHTV 120/600/..
The high-temperature tube furnaces are available in either horizontal (type RHTH) or vertical (type RHTV) designs. High-quality insulation materials made of vacuum-formed fiber plates enable energy-saving operation and a fast heating time due to low heat storage and heat conductivity. By using different gas supply systems, operations can be performed under non-flammable or flammable protective or reactive gases or under vacuum.
- Tmax 1600 °C, 1700 °C, or 1800 °C
- MoSi2 heating elements, mounted vertically for easy replacement
- Insulation with vacuum-formed ceramic fiber plates
- Rectangular outer housing with slots for convection cooling
- With frame for vertical operation
- Housing made of sheets of textured stainless steel
- Ceramic working tube made of material C 799 including fiber plugs operation under air
- Type B thermocouple
- Power unit with low-voltage transformer and thyristor
- Over-temperature limiter with adjustable cutout temperature for thermal protection class 2 in accordance with EN 60519-2 as temperature limiter to protect the furnace and load and with selectable maximum temperature gradient as tube protection
- Switchgear and control unit separate from furnace in separate floor standing cabinet
- Standard working tube
- NTLog Basic for Nabertherm controller: recording of process data with USB-flash drive
Additional equipment
- Charge control with temperature measurement in the working tube and in the furnace chamber outside the tube
- Display of inner tube temperature with additional thermocouple
- Gas tight flanges for protective gas and vacuum operation
- Manual or automatic gas supply system
- Check valve at gas outlet avoids intrusion of false air
- Alternative working tubes designed for process requirements
- More additional equipment on request
- Process control and documentation via VCD software package or Nabertherm Control Center (NCC) for monitoring, documentation and control
Controller: P 470
Model:
|
RHTV 50/150/1.7RHTV 50/150/1.6RHTV 120/600/1.8RHTV 120/600/1.7RHTV 120/600/1.6RHTV 80/300/1.8RHTV 80/300/1.7RHTV 80/300/1.6RHTV 50/150/1.8
|
Temperature max. of furnace:
|
1600°C1700°C1800°C
|
Heated length:
|
150 mm300 mm600 mm
|
Width outside (furnace):
|
500 mm580 mm
|
Height outside (furnace):
|
510 mm660 mm960 mm
|
Power (furnace):
|
5,4 kW10,3 kW19 kW
|
Tube diameter (outside):
|
50 mm80 mm120 mm
|
Tube length:
|
380 mm530 mm830 mm
|
Depth outside (furnace):
|
650 mm
|
Type of furnace:
|
high temperature furnacetube furnace
|
Model |
Outer dimensions W x D x H [mm]
|
Max. outer tube Ø [mm] |
Heated length [mm] |
Length constant temperature +/- 5 K [mm]3
|
Tube length [mm] |
Conected load [kW] |
Electrical connection |
Weight [kg] |
Horizontal design |
|
|
|
|
|
|
|
|
RHTH 50/150/.. |
4702 x 480 x 640 |
50 |
150 |
50 |
380 |
5.4 |
3-phase1
|
70 |
RHTH 80/300/.. |
6202 x 550 x 640 |
80 |
300 |
100 |
530 |
9.0 |
3-phase1
|
90 |
RHTH 120/600/.. |
9202 x 550 x 640 |
120 |
600 |
200 |
830 |
14.4 |
3-phase1
|
110 |
Vertical design |
|
|
|
|
|
|
|
|
RHTV 120/150/.. |
500 x 650 x 5102
|
50 |
150 |
30 |
380 |
5.4 |
3-phase1
|
70 |
RHTV 80/300/.. |
580 x 650 x 6602
|
80 |
300 |
80 |
530 |
10.3 |
3-phase1
|
90 |
RHTV 120/600/.. |
580 x 650 x 9602
|
120 |
600 |
170 |
830 |
19.0 |
3-phase1
|
110 |
1 Heating only between two phases
2 Without tube
3 Tmax. 1600°C, 1700°C or 1800°C (Tmax. is reached outside the tube. Temperature inside the tube up to - 50 K)