ENVAIR Safety cabinet eco safe Comfort Class II

Item number: ENVAIR_9002>

EAN: 4064343155199

Category: ENVAIR

Manufacturer: ENVAIR Deutschland

Price on application
useful Dimensions

There are variations of this item. Please select the variation you wish.


ENVAIR Safety cabinet eco safe Comfort Class II

ENVAIR eco safe Comfort Microbiological Safety Cabinets belong to the latest generation of laminar airflow systems, in which the choice of materials of construction of the highest quality guarantees conformity to the strictest safety standards.

ENVAIR eco safe Comfort vertical laminar flow cabinets are Class II Microbiological Safety Cabinets - designed and built to performance requirements of the EN-12469: 2000 European Standard, with 70% of the air re-circulated via the main Class H14 HEPA filter within the cabinet, whilst the remaining 30% is discharged through an exhaust Class H14 HEPA filter.

Safety Cabinets with automatic regulation and microprocessor based monitoring systems. These cabinets are suitable for handling micro-organisms and pathogens as defined by the appropriate European and other International Standards, current health and safety guidelines and legislation aimed at safeguarding health and safety of operators at work. ENVAIR eco safe Comfort Microbiological Safety Cabinets series are supplied with double centrifugal fan to provide complete operator, product and environmental protection. Moreover the series fitted with double motor-fan are designed and are also suitable to discharge the filtered air outside the laboratory through a ducting system, if required.

Respect for the environment motivates ENVAIR to manufacture laminar-flow, cytotoxic drug safety cabinets and microbiological safety cabinets possessing ultra-low environmental impact, by utilizing:
  • Certified ''low pressure-drop'' HEPA filters providing up to 30% saving on power consumption
  • Electronically controlled motor-blower with automatic pressure-drop compensation
  • 99% recyclable components
  • Innovative technologies such as the new ECS® microprocessor
ECS® Microprocessor based monitoring system:
full status report provided via 2-line digital display by the new generation microprocessors - which automatically control all functions and all safety alarm systems ensuring that performance characteristics are maintained to EN12469: 2000 requirements. High power lithium battery keeps safety data saved to microprocessor system. The user-friendly practical keyboard and the rear-lit LCD will continuously display all required data keeping the user constantly informed of the cabinet conditions in operation and in particular:
  • display of laminar airflow velocity and frontal air barrier velocity
  • display of inside and outside temperature
  • display of residual lifetime of HEPA filters, UV Lamp (if fitted)
  • display of total number of hours of operation
  • display of saturation level of HEPA filters 

Audio visual alarms provided for:

  • out of range or incorrect laminar airflow velocity and frontal
  • air barrier velocity
  • incorrect position of front sash-window saturation of HEPA filters
  • end of life-cycle of UV lamp (if fitted)
  • blockage in the exhaust duct
  • fan-motor malfunction
  • power failure
Certification: ISO 9001 certified

Configuration Overview:
  • Electrical upwards opening frontal screen for easy cleaning
  • Vacuum connection
  • Safety service connection for gas
  • 1 electrical socket at 0.9 m and 1.2 m
  • 2 electrical sockets at 1.5 m and 1.8 m
  • Operation mode for overnight-reduction
  • Anti bacterial coating
  • Low noise level
  • Stainless steel AISI 316L
  • Real Laminar Flow

Note: media connections when ordering with specify a retrofit is not possible.


Customizing services (Selection)
  • 24h at site service and 24h free of charge phone hotline, 7 days a week
  • 10 years Spare parts guaranty. Availability within 24h
  • Qualification: IQ/OQ, GMP, GAMP and 21 CFR Part 11
  • We offer a 2-year warranty to all units (with maintenance contract)

Width: 1001 mm - 1100 mm1301 mm - 1400 mm1601 mm - 1700 mm1901 mm - 2000 mm
Device type: safety cabinet
Height: 1401 mm - 1500 mm
Safety class: class II
Depth: 801 mm - 900 mm
Safety cabinets ENVAIR eco safe Comfort Class II
0.9 m 1.2 m 1.5 m 1.8 m
Overall Dimensions WxHxD (1)
(mm)
1045x1500x860 1350x1500x860 1655x1500x860 1960x1500x860
Useful Dimensions WxHxD
(mm)
887x740x580 1192x740x580 1497x740x580 1802x740x580
Working aperture 200 mm 200 mm 200 mm 200 mm
Max front aperture 440 mm 440 mm 440 mm 440 mm
Weight 170 kg 196 kg 225 kg 260 kg
Exhaust flow rate 290 m3/h 390 m3/h 485 m3/h 585 m3/h
Noise level (2) < 53 dB(A) < 54 dB(A) < 55 dB(A) < 56 dB(A)
Lighting level >1100 lux >1200 lux >1300 lux >1300 lux
Electrical Data 1Ph+E - 230V
50Hz
1Ph+E - 230V
50Hz
1Ph+E - 230V
50Hz
1Ph+E - 230V
50Hz
Power consumption 281 W 390 W 587 W 691 W
Current consumption (2) (3) 1.9 A 2.1 A 3.4 A 3.6 A
Electrical class / IP 1 / 20 1 / 20 1 / 20 1 / 20
Internal electrical outlet 6 A 6 A 6 A 6 A
Heat emission 175 W 240 W 295 W 360 W

(1) The total depth of the cabinet can be easily reduced to 780 mm by removing the back panel
(2) At operation condition according to EN12469: 2000
(3) Clean filters, lighting activated, internal outlet load excluded
Envair offers service in pure culture. We do not simply sell our units to you but will assist you gladly from A to Z.

Delivery:
We deliver all units ex works.
Set-up service and packaging disposal are included upon request.

Service:
- 24h at site service and 24h free of charge phone hotline
- 7 days a week

Spare parts guaranty:
- 10 years
- Availability within 24h
- Ex stock Emmendingen

Qualification:
- IQ/OQ
- GMP
- GAMP
- 21 CFR Part 11

Decontamination:
We carry out microbiological decontaminations with most modern H2O2 generators in Cleanrooms, Isolators and Safety Cabinets.

Maintenance:
- Microbiological Safety Cabinets DIN 12469
- Cytotoxic Dispensing Cabinets with KI-discus test DIN 12980
- Laminar Flow Cabinets
- Laboratory Fume Hoods
- Cytotoxic Dispensing Isolator DIN 12980
- Isolator EN 14644-7
- Cleanrooms
- Autoclaves
- CO2 Incubator
- Ultra Low Temperature Freezer -86 °C

Service by professional staff. All works are carried out by service technicians qualified by TÜV Nord.

Maintenance contract:
Regular terms of maintenance increase your safety.
With a maintenance contract we guarantee the complete check of all functions of your units. We will contact you reliably in regular terms.

Guaranty and Warranty:
Combined with an ENVAIR maintenance contract we offer a 2-year warranty to all units. Excepted are consumables and wearing parts as well as compressed air components.

Katalog

Catalog


Accessories


Related products