Spetec Laminar Flow Module FMS Series "SuSi"
The Spetec Laminar Flow Module FMS Series "SuSi" offers a first-class solution for highly sensitive cleanroom applications where maximum air purity and strict contamination control are essential. Developed for areas such as semiconductor technology, optoelectronics and laser technology, this flow module is a high-quality and flexible alternative to conventional cleanroom workbenches. Compared to other systems, this product series impresses with TÜV-certified safety standards, versatile model variants and a consistently user-oriented design that facilitates adaptation and integration into existing processes.
Innovative technology for clean rooms
Modularity and performance features
As the heart of modern clean room technology, the FMS "SuSi" offers an optimised overall concept combining safety, flexibility and efficiency. The precise workmanship with a focus on safety and durability appeals to professional users, as does the wide range of sizes, which extends from compact workstation solutions to large-area modules. The following features are particularly noteworthy:
- TÜV-certified and tested in accordance with DIN EN ISO 14644 and GMP
-
Modular expandability: Various equipment variants, from 601 mm to 1900 mm in width
-
Large filter areas: Variants from 610 x 400 mm to 1830 x 610 mm possible
-
Easy integration: Adaptable designs for flexible integration into existing systems
-
Quiet and energy-efficient operation: Low noise level and CO2 emissions
- Safety glass for optimum visibility and protection
-
Intuitive maintenance: Easy access to filter modules, quick filter changes
The available model variants (e.g. FMS 24, FMS 37, FMS 56, FMS 75, FMS 93, FMS 112) each offer specific filter areas and external dimensions to ensure maximum adaptation to individual room configurations. The easy-to-handle design greatly simplifies installation, maintenance and inspection. Each unit meets the requirements of demanding production environments, such as those found in semiconductor and medical technology, food production, research laboratories or precision engineering.
Specifications at a glance
-
Width: 901 mm to 1900 mm (depending on model)
-
Depth: 601 mm to 700 mm
-
Height: Up to 500 mm
-
Filter area: 610 x 400 mm to 1830 x 610 mm
-
Weight: 20 kg to 63 kg (depending on model)
-
External dimensions (W x D x H): e.g. 676 x 669 x 430.5 mm to 1896 x 669 x 430.5 mm
-
Window material: High-quality safety glass
-
Filter type: HEPA, easy to replace
These details ensure flexible planning and offer maximum planning reliability for cleanroom managers.
Safety standards and certifications
Each module complies with the European standards DIN EN ISO 14644 and the current GMP guidelines. Regular calibration of all measuring and monitoring devices every 12 months ensures the conformity of the system. A comprehensive testing and certification process ensures reliable operating quality and comprehensive documentation - crucial for applications that depend on maximum product safety. Applications in demanding environments The range of applications for this solution is wide. Typical areas of application and practical examples include:
-
Semiconductor production: Protection of highly sensitive chips and wafers during assembly, testing and packaging
-
Optics and optoelectronics manufacturing: Dust-free assembly and inspection of lenses, sensors and precision optics
-
Laser safety areas: Protected areas for the assembly and maintenance of laser systems
-
Food production: Hygienic filling and packaging, especially for products intended for export to countries with strict GMP requirements
-
Research laboratories: Preparation and processing of samples under controlled sterile conditions
Typical substances that can be safely processed with the module include silicon semiconductor wafers, optical glass, laboratory reactants and high-purity food ingredients, among others.
FAQs
How often should the filters be changed?
Depending on usage, environment and particle load, filters should be checked and replaced at least once a year, or more frequently if used intensively.
What standards and certificates does the module comply with?
The module is TÜV-certified and complies with the requirements of DIN EN ISO 14644 and all relevant GMP guidelines for clean rooms.
Can the module be used in existing clean room systems?
Yes, thanks to its modular design and compatible connection options, the module can be flexibly integrated into existing infrastructure.
What sizes and designs are available?
Various models are available in widths from approx. 900 mm to 1900 mm and in several depth and height levels; the exact dimensions depend on the specific application requirements.
Conclusion
The FMS "SuSi" series combines first-class air purity with flexible engineering and user-friendly technology. The variety of sizes, certified safety in accordance with internationally recognised standards, ease of maintenance and energy efficiency make this flow module a first-class choice in cleanroom technology - especially for companies that need to ensure the highest standards in technology and product purity.