Dräger Interlock XT

components
The Dräger Interlock XT consists of two main components: the breath-alcohol measuring instrument with the measuring system, which is located in the interior of the vehicle and the control unit, which is usually installed under the dashboard and allows the power supply to the vehicle's starter, or blocked.

use
Long waiting times after the ignition is perceived by a motorist as particularly troublesome. Therefore, special attention was placed on a fast readiness for use in the development of the Dräger Interlock XT. Because the Dräger Interlock XT also (eg in the Scandinavian winter) and at 85°C (eg in direct sunlight) is working properly at -45°C, it was given the name "XT" for "eXtended Temperature".

data Storage
While the use of the vehicle of the Dräger Interlock XT is stored in a data storage recorded all relevant for the application events: date, time, submission or refusal of a breath sample, measured alcohol concentration, motor starts and stops, electrical bypassing of the Interlock and other tampering. The data can be read out and collected in a log.

operation
After the ignition is switched on, the Dräger Interlock XT requests a breath sample. The result of the breath alcohol concentration determines whether the starter of the vehicle is unlocked and the engine can be started.

measurement
The Dräger Interlock XT determines the breath alcohol concentration with an electrochemical sensor system, as it is also used in breath alcohol measuring devices the police. It reacts with high specificity to alcohol, so that other exhaled substances do not affect the measuring result.

manipulation
The use of tools to bypass the Dräger Interlock XT, such as eg an air pump which safely identifies and prevents the engine starting.

Since the general operating permit is valid only for Germany, this unit can be sold only in Germany.

Interlock XT
Principle of measurement Electrochemical Sensor
Environmental Operating Conditions Temperature from -45 to 85 ° C.
operational readiness < 20 sec. (over 20°C)
< 3 min. (-40°C)
display Graphical LCD display on the handset with full text messages
calibration interval typically 12 months
data memory in the control unit, more than 30,000 operations
Dimensions (H x W x D) Hand-held device: approx. 150 mm x 70 mm x 40 mm
Controller: approx. 115 mm x 105 mm x 40 mm
weight Handset: approx. 175 g
Control unit: approx. 320 g
power supply 12 to 24 V; The output relay can switch up to 48 V
Switching relay for the management of the starter relay < 16 A, continuous; < 40 A, peak
power consumption < 2 A, a maximum; < 20 mA in standby
Approvals General operating, Germany
EN 50436-1: 2005, EN 50436-2: 2007
e-label (EU Directive 72/245/EEC with the last amendment applicable)