Dräger PAC 6500
The robust Dräger Pac 6500 is your reliable companion under tough conditions. The personal single-gas detection device measures CO, H2S, SO2 or O2 quickly and precisely. Quick sensor response times and a replaceable battery also ensure safety.
Strong performance for maximum safety
You can rely on the Dräger Pac 6500: the personal single-gas detection device warns against hazardous concentrations of carbon monoxide, hydrogen sulfide, sulfide dioxide or oxygen with precision and reliability.
Powerful sensors with a very low t-90 response time ensure quick reactions. The Pac 6500 is versatile thanks to its wide measurement range. For example, the CO sensor measures concentrations from 1 to 1,999 ppm, and the H2S sensor from 0.4 to 100 ppm.
Easy handling thanks to clear user guidance
The D-Light indicates whether functionality of the device has been tested and whether it is ready to use. The housing is also designed with your safety in mind: each sensor variant of the Dräger Pac 6500 features clearly visible color coding, thereby minimizing the chance of mistakes.
Robust design -even for the toughest conditions
The Pac 6500 is easily handled in even extreme conditions. Depending on the sensor, temperatures from -40 °C to 55 °C and air pressures between 700 and 1,300 mbar can be tolerated.
A membrane filter protects the sensor from foreign matter such as dust and liquids. The shock-proof, chemical-resistant housing meets the requirements specified in the IP68 standard rating.
User-friendly display with all important information
The large display clearly indicates the respective gas concentration. Other important information, such as the battery capacity, is also displayed. The bright backlighting ensures that all values are clearly legible in the dark.
360° alarm with various functions
If the Dräger Pac 6500 measures hazardous gas concentrations, it sets off an audible, visual and perceptible vibrating alarm. Two bright, flashing LEDs on the top and bottom of the device ensure that the alarm is easily visible from all sides. The acoustic signal reaches a volume of 90 dB. The display can show the peak concentration measured at any given moment. Earlier alarms registered can also be retrieved at a later time, even if they have been acknowledged.
The Pac 6500 with oxygen sensor has two additional alarm thresholds in addition to the standard alarm threshold settings. This provides an additional level of safety as a pre-alarm, in addition to the main alarm, can be set for both oxygen enriched and oxygen deficient atmospheres.
Data logger and event logger for analyses and reports
The Dräger Pac 6500 logs concentrations and events along with the date and time. The data can be loaded on a PC via an interface and processed further there.
Economical operating costs
All versions of the Pac 6500 are equipped with extremely durable DrägerSensors and a powerful battery. Neither the sensor nor the battery need to be changed over the minimum two-year maintenance-free service life of the H2S, SO2 and CO versions.
The Pac 6500 is protected against water, dust and other foreign bodies by a special membrane filter. When the filter becomes heavily soiled in use, you can quickly and easily replace it yourself. The device is then ready to use again right away.
Fast function test saves time and money
Function tests and calibrations can be carried in the Dräger X-dock calibration station. The automatic bump tests in the X-dock are a cost-efficient and convenient solution thanks to the short test duration and the extremely low consumption of test gas. The Pac 6500 is simply placed in the bump test station and automatically selects the correct setting.
Note: The system components Bump Test Station, X-dock and Sensor XXS can be ordered on request.
Measurement type:
|
Single-Gas Detection Device
|
Dräger Single-Gas Detection Device |
PAC 6000 |
PAC 6500 |
Limited operating time (2 years) |
+ |
|
Unlimited operating time |
|
+ |
Service life indicator |
+ |
(+)1
|
Temperature to -40 °C |
+ |
+ |
Battery capacity indicator |
+ |
+ |
Replaceable sensor grid |
+ |
+ |
Peak |
+ |
+ |
TLV2
|
|
+ |
STEL3
|
|
+ |
Event logger |
+ |
+ |
Data logger |
|
+ |
Standard gases |
+ |
+ |
Special gases |
|
|
Dual sensor |
|
|
Default setting Calibration interval4
|
122 days (4 month) |
122 days (4 month) |
1) Configurable
2) TLV = Threshold Limit Values
3) STEL = Short Term Exposure Limit
4) According to the regulations of T021/T023