em-tec BioProTT Bundle3: FlowTrack DINrail + BCT - ProfiLab24 GmbH
99
100
24
4
stars -
Professional service
Customer
Young team with a lot of ambition and quick answers to all questions. We needed a complete laboratory equipment for our new location. The team of Profiab24 has arranged everything.
em-tec BioProTT Bundle3: FlowTrack DINrail + BCT in Measurement Technology
Item number: EMTEC_37007
EAN: 4064343195898
Manufacturer:
em-tec
em-tec BioProTT Bundle3: FlowTrack DINrail + BCT. Order at ProfiLab24.com Online Catalog. Fast delivery. Secure payment and 24/7 service.
em-tec BioProTTTM Bundle3: FlowTrack DINrail + BCT
- Non-invasive flow measurement for liquids
- Monitor volumetric flow in real time
- Compact, space saving design
- Flow meter variant for DIN rail mounting
- Low 3 Watt power consumption
BioProTTTM FlowTrack, FlowTrack plus and FlowTrack DINrail
BioProTTTM is em-tec's precise non-invasive solution for reliable and economical liquid flow measurement for improved bioprocess management. We measure an actual volume flow rate in real time, allowing you to adjust pump speed to deliver accurate fluid volumes and thereby mitigating the risk imposed by poor pump performance.
Clamp On and Get Started Installation BioProTT
TM Clamp-On Transducers attach easily to the outside of flexible tubing eliminating the need for splicing the lines or interrupting the process. They do not make contact with the fluid, induce shear stress on cells, or cause a pressure drop in the system. Transducers are just as easily removed at the end of the process, with minimal cleaning and disinfection required. They do not require recalibration prior to each use. Whether you use single-use components or reusable systems, our economical flow measurement system can be used for years without the operating costs associated with disposables.
Choose a Model to Suit Your Process Innovative design coupled with integrated electronics enable a truly compact, space saving footprint. Three standard flow meter models are available: The BioProTT
TM FlowTrack plus includes an LCD display with features such as totalization, user adjustable calibration factor and multiple calibration tables for transducers, which can be managed at the device. The blind BioProTT
TM FlowTrack is ideal for those who prefer to view all associated process parameters on their bioprocess management system. For those desiring to integrate the system into standard industry enclosures we offer a DIN rail mounted option with the same fit and function of the BioProTT
TM FlowTrack.
All models are enabled with analog current (4-20mA) output for flow and received signal strength (RSS), and RS232 digital output for seamless integration into any process control system.
BioProTTTM at a glance
- Non-invasive, real-time flow measurement
- Clamp on and get started installation
- Excellent accuracy, repeatability and stability
- Economical and reusable
- 4-20mA or digital RS-232 output signals
- Customer specified calibration for tubing, temperature and media
- User adjustable calibration enables field changes
The BioProTTTM Flow Measurement System is ideal for
- Single use systems
- Automated processes
- Processes utilizing flexible tubing
- Processes sensitive to shearing effects
- Processes requiring sterility in the lines
...because real time flow measurement
- delivers improved process performance by maintaining accurate and reliable media delivery rates
- reduces process risk from poor pump performance by helping to deliver accurate volumes to feeder tanks and reactors
- reduces equipment footprint by replacing large weighing scales with flow meters
- enables bioprocess automation with continuous real time flow monitoring and recording
em-tec BioProTTTM Clamp-On Transducer
- Non-invasive Clamp-On Transducers for flexible tubing
- Easy to install - no need to splice lines or stop process
- No pressure drop in system
- Does not induce additional shear stress
- Economical - reusable transducers last for years
Measurement type:
|
Ultrasonic flowmeter
|
Shipping weight: |
1,50 Kg |
Product weight: |
0,64 Kg |
BioProTTTM |
FlowTrack DINrail |
Technical Specifications |
|
Operating principle |
Transit-time Ultrasound |
Size (HxWxL) |
110 x 65 x 150 mm |
Weight |
635 g |
Case material |
Aluminium |
IP-Code |
IP20 |
Supply voltage |
24 V DC ( + 10%) via power adapter or external supply |
Power consumption |
Typically 3 Watt, max. 8 Watt |
Power supply |
Included with EU, UK, North America and IEC 60320 C8 connectors; others on request |
DIN rail mounting type |
Top hat section type O according to EN 50022, 35 mm x 7.5 mm |
Flow sensor extension cable |
1 m; zum Sensoranschluss von außen Schaltschrank ermöglichen |
Compatible flow sensors |
BioProTTTM Clamp-On Transducer |
Interfaces |
|
Interface types |
digital RS-232 4-20mA analogue: flow and acoustic coupling (RSS) |
RS-232 cable |
Shielded, 9-pin D-Sub-cable (M/F), USB adapter included |
Accuracy |
|
Flow range |
See BioProTTTM Clamp-On Transducer data sheet |
Accuracy of flow measurement |
See BioProTTTM Clamp-On Transducer data sheet |
Resolution of flow measurement |
1 ml/min |
On site calibration |
Adjustment with user adaptable calibration factor |
Ambient Conditions |
|
Air pressure |
70 to 106 kPa |
Operating temperature range |
10 to 40 ºC (50 to 104° F) |
Storage temperature range |
-20 to 45° C (- 4 to 113° F) |
Transport temperature range |
-20 to 55° C (- 4 to 131° F) |
Humidity storage, transport and operation |
10 to 96 % (non-condensing) |
Type |
Maximum Flow Range 1) |
Tube size in inch |
Tube size in mm |
|
[l/min] |
ID x WT ["] |
OD ["] |
ID x WT [mm] |
OD [mm] |
BCT 1/8 x 1/16" A |
up to ± 4 |
1/8 x 1/16 |
1/4 |
3.18 x 1.59 |
6.35 |
BCT 11/64 x 3/64" A |
up to ± 6 |
11/64 x 3/64 |
17/64 |
4.30 x 1.25 |
6.80 |
BCT 3/16 x 1/16" A |
up to ± 6 |
3/16 x 1/16 |
5/16 |
4.76 x 1.59 |
7.94 |
BCT 1/4 x 1/16" A |
up to ± 8 |
1/4 x 1/16 |
3/8 |
6.35 x 1.59 |
9.53 |
BCT 1/4 x 3/32" A |
up to ± 8 |
1/4 x 3/32 |
7/16 |
6.35 x 2.38 |
11.11 |
BCT 3/8 x 1/16" A |
up to ± 10 |
3/8 x 1/16 |
1/2 |
9.53 x 1.59 |
12.70 |
BCT 3/8 x 3/32" A |
up to ± 10 |
3/8 x 3/32 |
9/16 |
9.53 x 2.38 |
14.29 |
BCT 3/8 x 1/8" A |
up to ± 10 |
3/8 x 1/8 |
5/8 |
9.53 x 3.18 |
15.88 |
BCT 1/2 x 3/32" A |
up to ± 20 |
1/2 x 3/32 |
11/16 |
12.70 x 2.38 |
17.46 |
BCT 1/2 x 1/8" A |
up to ± 20 |
1/2 x 1/8 |
3/4 |
12.70 x 3.18 |
19.05 |
BCT 1/2 x 3/16 |
up to ± 20 |
1/2 x 3/16 |
7/8 |
12.70 x 4.76 |
22.23 |
BCT 3/4 x 1/8 |
up to ± 20 |
3/4 x 1/8 |
1 |
19.05 x 3.18 |
25.40 |
BCT 3/4 x 3/16 |
up to ± 30 |
3/4 x 3/16 |
9/8 |
19.05 x 4.76 |
28.56 |
1) depending on medium and tube size
-
ID = inner diameter
-
OD = outer diameter
-
WT = wall thickness
-
BCT = BioProTTTM Clamp - On Transducer
Technical Specifications |
|
Size (HxWxL) |
25 x 33 x 45 mm (tube inner diameter / ID < 1/2") 27 x 38 x 51 mm (tube inner diameter / ID = 1/2") |
Total weight (incl. cable/plug) |
137 g (tube ID < 1/2") 153 g (tube ID = 1/2") |
Weight sensor head |
52 g (tube ID < 1/2") 72 g (tube ID = 1/2") |
Housing / lid material |
Epoxy resin, aluminium, stainless steel |
Cable length |
2.9 m |
IP - Code |
IP65 |
Fluid types |
Water, Buffer Solutions, Cell Culture Media, Fermentation Media, Non-Aerated Liquids |
Tubing types |
e.g. Silicon, PVC and Polyurethanes, including Tygon®, C - flex®, Pharmed®, others on request |
Medium operating temperature |
4 to 50° C (40 to 122° F) |
Calibration tables |
Up to 7 calibration tables can be stored in one sensor |
Cleaning and disinfection |
Disinfect easily using alcohol based surface cleaners |
Compatible flow meters |
BioProTTTM Flow Track, Flow Track plus, Flow Track DINrail |
Accuracy in combination with BioProTTTM flow meters
|
|
Accuracy |
± 3% of reading ± max. 20 ml/min |
Reference conditions for above accuracy statement: |
|
Liquid temperature |
Calibration temperature ± 5 ° C (± 9 ° F ) |
Ambient temperature |
20° C ± 5 ° C (68 ° ± 9 ° F ) |
Straight inlet section |
10 x ID of tubing, fully developed flow profile |
Tubing |
Raumedic - ECC - Blood Line PVC with acoustic couplant applied |