Dräger X-plore 7300 - ProfiLab24 GmbH
99
100
24
4
stars -
Professional service
Customer
Young team with a lot of ambition and quick answers to all questions. We needed a complete laboratory equipment for our new location. The team of Profiab24 has arranged everything.
Dräger X-plore 7300 in Protective Equipment
Item number: DRAEG_39021
EAN: 4026056004072
Manufacturer:
Dräger
Dräger X-plore 7300 at ProfiLab24 dealer for laboratory equipment. Made in Germany with top advice and 24H service.
Dräger X-plore 7300Powered air purifying respirators - the alternative for greater comfort
Especially in challenging activities with long wear times can offer the user a significant assistance blower-assisted respirators.
ADVANTAGES OF FAN FILTER AGAINST TRADITIONAL MASKS AND FILTER COMBINATIONS:
- high wearing comfort: breathing air is supplied cleaned the user
- for devices with open headers no G26-screening needed
- no prescribed wearing time limitation in the use of helmets, hoods and visors
- Anti-fogging effect and cooling by constant air flow
- ideal application for beard and wearing glasses
THE Dräger X-plore ® 7000 SERIES:
- a variety of combinations with
Dräger X-plore helmets, hoods, visors,
Dräger X-plore 4740 half masks and
Dräger X-plore 6000 full face masks
- maximum flexibility thanks to extensive accessories
- Security through audible and visual alarm (eg low battery)
- maximum range of applications
- Dräger X-plore 7300: Application to grinding and bottling works in metal processing and in many welding processes
- Dräger X-plore 7500: Application in painting and when handling chemicals
Dräger X-plore ® 7300
Air purifying respirator with many possible combinations for protection against harmful particles
ADVANTAGES:
- effective respiratory protection against particles
- high wearing comfort
- freed without breathing resistance and the G26-screening: the use of open Headboards
Protective equipment:
|
powered air purifying respirator
|
Shipping weight: |
0,86 Kg |
Dimensions: |
× × cm |
LIMITS OF USE
|
protection class |
multiple 1) the limit 2)
|
limitations of use |
TH1 |
5 |
Devices of class TH1 may not violate carcinogenic, very toxic and radioactive gases and vapors and airborne biological agents of risk groups 2 and 3 and enzymes are used |
TH2 |
20 |
- |
TH3 |
100 |
- |
TM1 |
10 |
A Class TM1 may not be used against radioactive gases and vapors |
TM2 |
100 |
- |
TM3 |
500 |
- |
1) - According to EN 529:2005 possible, changes by national regulations.
2) - Set country-specific, maximum to exceed the exposure limit value with respiratory protective equipment.
SPECIFICATIONS
|
Approvals |
EN 12941 (with Dräger X-plore helmets, hoods and visors) EN 12942 (with Dräger X-plore 4740/6000 Half and Full Face Masks) |
Air delivery |
adjustable 140-210 l / min |
Battery technology |
NiMH battery 4,8 V / 4,5 Ah, single charger with overcharge protection |
Weight |
900 g (Blower unit including filter and battery) |
filter class |
TH3 P SL R (with Dräger X-plore helmets, hoods and visors) TM3 P SL R (with Dräger X-plore 4740/6000 Half and Full Face Masks) |
period of use |
6 - 15 hours (depending on the set of the air delivery and the pollutant concentration) |
marking P |
to protect against particles |
marking SL (Solid & Liquid) |
used against aerosols |
marking R |
suitable for use over several shifts |