PHOENIX Instrument Ozone Generator OZ
Efficient, chemical-free room disinfection is a key concern in many laboratories, medical facilities, food processing plants and public areas. With its powerful, automated ozone generation, the PHOENIX Instrument Ozone Generator OZ offers the perfect solution for users who want safe, fast and thorough disinfection without chemical residues. Thanks to various power levels, robust construction and an intelligent timer function, this device clearly stands out from conventional disinfection systems and is recommended for structured and economical hygiene concepts.
Innovative technology for professional hygiene requirements
The ozone generator impresses with its versatility and flexibility in a wide range of applications relating to disinfection and odour neutralisation. The device generates ozone (O3) directly on site from atmospheric oxygen and directs it powerfully into the desired area of application. This effectively inactivates pathogenic microorganisms, viruses, bacteria and mould. The two available model variants for different room sizes deserve special attention:
-
OZ-10 for medium-sized rooms up to 100 m³ (36 m² area with 2.8 m room height) and
-
OZ-30 for large rooms up to 320 m³ (82 m² area).
Technical highlights at a glance:
- Ozone output: either 10 g/h (OZ-10) or 30 g/h (OZ-30)
- Automatic timer function for disinfection outside operating hours
- Volume flow: 150 m³/h (OZ-10) or 230 m³/h (OZ-30) for even ozone distribution
- Flexible operating conditions: ambient temperature 0-40 °C, humidity up to max. 70%
- Power consumption: 130 W (OZ-10), 250 W (OZ-30), power supply: 220-240 V / 50 Hz
- Compact design: OZ-10 - 170 x 380 x 260 mm (4 kg), OZ-30 - 220 x 440 x 305 mm (6 kg)
- Intuitive operation and mobile use thanks to low weight
In addition to these core parameters, the intelligent control system with integrated timer ensures an automated disinfection process. Users can adapt the ozonation cycle precisely to their working hours, which significantly reduces the workload for staff, especially in laboratory and production environments with shift work. After use, the ozone decomposes into oxygen within a few hours, leaving no residue, and the area can be used safely after a short period of ventilation.
Special features and practical advantages:
Efficient air circulation with powerful fans transports ozone even into hard-to-reach corners and reliably reaches surfaces. The models are designed for continuous operation and offer a safe, pollutant-free alternative to conventional disinfectants. Ozone does not attack surfaces or materials, provided that the recommended operating conditions are observed.
The generator's design meets all relevant electrical safety requirements for laboratory and industrial equipment. Its operation is based on applicable occupational exposure limits for ozone and ensures that there is no safety risk to users when used as recommended. Integrated control functions and automation mechanisms prevent misuse and reliably protect personnel and inventory.
Specific applications in everyday practice
The ozone generator can be used to meet a wide range of professional requirements, including:
-
Laboratories: Germ reduction and hygienic treatment of microbiological workrooms
-
Food processing: Residue-free surface disinfection and odour control, for example in sausage and bakery production, dairies or beverage production
-
Medical practices & clinics: Rapid disinfection of treatment rooms, patient rooms, functional areas
-
Hotels & common areas: Effective odour neutralisation and hygiene in kitchens, sanitary areas and dining rooms
-
Storage & transport areas: Decontamination of storage rooms and climate chambers
-
Canteens & commercial kitchens: Protection against mould, bacterial residues and organic odours after cleaning
Ozone offers effective control and reduction, especially for surfaces where bacteria, yeasts, mould spores or organic residues (such as proteins, fats from food, body fluids) regularly occur. The ability to verify success using a rapid protein test ensures the quality and traceability of hygiene processes.
FAQs
How safe is it to use?
If the operating instructions are followed and the room is ventilated, repeated use for room disinfection is safe.
How quickly does ozone decay after treatment?
Ozone usually decays completely into oxygen within 1-3 hours. After disinfection, a short ventilation phase is usually sufficient.
What should be considered when operating in high humidity?
Relative humidity of up to 70% is possible without any problems. In cases of extremely high humidity, it is advisable to check material compatibility.
What residues remain after disinfection?
Ozone itself decomposes completely into oxygen. When used correctly, no harmful or chemical residues are produced.
For which microorganisms is the device particularly effective?
Bacteria (e.g. E. coli, salmonella), various viruses, mould and yeast fungi, as well as organic odours (e.g. from food or waste) are reliably inactivated by ozone.
Conclusion
The ozone generator from PHOENIX Instrument combines high effectiveness, maximum user safety and practical flexibility for professional hygiene concepts. With automated, powerful disinfection cycles without chemicals, the device achieves excellent results in laboratories as well as in demanding industrial or public environments, thus meeting the requirements for modern, sustainable disinfection technologies in the best possible way.