Dräger X-plore ® bayonet filters

Item number: DRAEG_Z0182

EAN: 4064343255523

Category: Dräger

Manufacturer: Dräger

Price on application
variations

There are variations of this item. Please select the variation you wish.


Dräger X-plore ® bayonet filters

Filters for the two-filter, half and full face masks Dräger X-plore ® 3300, 3500 and 5500

ADVANTAGES:
  • Dräger-specific bayonet connection
    • easy installation:
      unique filter guide and tactile point
    • additional handling safety:
      marks on mask and filter as well as the direction of arrow
  • Rugged plastic housing
  • Packed in pairs
    • open only the required number of filter packaging
  • More flexibility with modular accessories
    • Compilation of combination filters of gas and particulate filters possible
    • optional pre-filter for longer service life

variation label Filter characterizing color special
particulate filter
A Pad P1 NR white 20
B Pad P2 R white 20
C P3 R mit Gehäuse white 22
D Pure P2 R white 20
E Pure P3 R white 20
F Pure Odour P3 R white 20
gas filter
G A1 brown 20
H A2 brown 20
I A2B2 brown, gray 18
J A1B1E1 brown, gray, yellow 20
K A1B1E1K1 brown, gray, yellow, green 20
combination filter
L A1 P3 R D brown, gray, white 14
M A2 P3 R D brown, gray, white 14
N A2B2 P3 R D brown, gray, white 12
O A1B1E1K1 Hg P3 R D brown, gray, yellow, green, red, white 14
P A2B2E2K2 Hg P3 R D
(Only for use with full face mask)
brown, gray, yellow, green, red, white 10



characterizing color Filter type Main areas of application
Brown AX1) Gases and vapors of organic compounds, boiling point < 65 °C
Brown A Gases and vapors of organic compounds, boiling point > 65 °C
Gray B inorganic gases and vapors, such as chlorine, hydrogen sulfide, hydrogen cyanide (HCN)
Yellow E Sulfur dioxide, hydrogen chloride
Green K ammonia
Black CO2) carbon monoxide
Red Hg3) mercury vapor
Blue NO4) nitrous gases, including nitric oxide
Orange Reaktor radioiodine, including radioactive iodomethane
White P particle


1) AX-filter may be used only in the delivery state (factory fresh). Reuse and use against gas mixtures is absolutely inadmissible.
2) CO filter may be used only once and must be disposed of after use.
3) Hg filters may acc. EN 14387 for max. 50 hours are used.
4) NO filter may be used only once and must be disposed of after use.

filter class capacity/
Separation efficiency
Maximum allowable concentration of pollutants
(according to EN Report 529, EN 14387)
Maximum allowable concentration of pollutants
(according to BGR 190, EN 14387)
particulate filter
1 small 4 x Limit with half mask
5 x Limit with full face mask
4 x Limit with half mask
4 x Limit with full face mask
2 medium 12 x Limit with half mask
16 x Limit with full face mask
10 x Limit with half mask
15 x Limit with full face mask
3 large 48 x Limit with half mask
1.000 x Limit with full face mask
30 x Limit with half mask
400 x Limit with full face mask
gas filters
1 small 0,1 Vol.-% (1.000 ppm)* 0,1 Vol.-% (1.000 ppm)**
2 medium 0,5 Vol.-% (5.000 ppm)* 0,5 Vol.-% (5.000 ppm)**
3 large 1,0 Vol.-% (10.000 ppm)* 1,0 Vol.-% (10.000 ppm)**


* Up to 50 times the OEL with half mask / max. 2,000 x limit with full face mask.
** Max 30 times the OEL with half mask / max. 400 x limit with full face mask.
The values ??correspond to the specified sources. Other national or local regulations must be observed.