Dräger X-plore® Rd40 filterFilter for all available on the market half and full face masks with a respirator in accordance with EN 148-1
ADVANTAGES:
- aluminum housing
- for extra safety: easily detected, filter damage
- Individually packed and resealable
- for optimum protection and longer service
- each with instructions for use
- Maximum protection through extensive types of filter program
- optimal protection against almost all hazardous substances - including CO and radioactive iodomethane
- Filters also available as X-tended version
- 30% higher service life compared to standard requirements
Shipping weight: |
0,20 Kg |
Dimensions: |
× × cm |
variation label |
Filter |
characterizing color |
special |
|
gas filter |
|
|
A |
1140 AXB2 |
brown, gray |
|
B |
1140 A2B2E2K2 |
brown, gray, yellow, green |
|
|
|
|
|
|
combination filter |
|
|
C |
1140 A2B2E2K2 Hg P3 R D |
brown, gray, yellow, green, white, red |
|
D |
1140 A1B2E2K1 Hg NO CO 20 P3 R D |
brown, gray, yellow, green, white, red, black, blue |
|
E |
1140 A2B2E2K2 Hg NO CO 20 P3 R D |
brown, gray, yellow, green, white, red, black, blue |
|
F |
1140 A2 P3 R D / Reaktor |
brown, orange, white |
incinerable |
characterizing color |
Filter type |
Main areas of application |
Brown |
AX1)
|
Gases and vapors of organic compounds, boiling point < 65 °C |
Brown |
A |
Gases and vapors of organic compounds, boiling point > 65 °C |
Gray |
B |
inorganic gases and vapors, such as chlorine, hydrogen sulfide, hydrogen cyanide (HCN) |
Yellow |
E |
Sulfur dioxide, hydrogen chloride |
Green |
K |
ammonia |
Black |
CO2)
|
carbon monoxide |
Red |
Hg3)
|
mercury vapor |
Blue |
NO4)
|
nitrous gases, including nitric oxide |
Orange |
Reaktor |
radioiodine, including radioactive iodomethane |
White |
P |
particle |
1) AX-filter may be used only in the delivery state (factory fresh). Reuse and use against gas mixtures is absolutely inadmissible.
2) CO filter may be used only once and must be disposed of after use.
3) Hg filters may acc. EN 14387 for max. 50 hours are used.
4) NO filter may be used only once and must be disposed of after use.
filter class |
capacity/ Separation efficiency |
Maximum allowable concentration of pollutants (according to EN Report 529, EN 14387) |
Maximum allowable concentration of pollutants (according to BGR 190, EN 14387) |
particulate filter |
|
|
|
1 |
small |
4 x Limit with half mask 5 x Limit with full face mask |
4 x Limit with half mask 4 x Limit with full face mask |
2 |
medium |
12 x Limit with half mask 16 x Limit with full face mask |
10 x Limit with half mask 15 x Limit with full face mask |
3 |
large |
48 x Limit with half mask 1.000 x Limit with full face mask |
30 x Limit with half mask 400 x Limit with full face mask |
|
|
|
|
gas filters |
|
|
|
1 |
small |
0,1 Vol.-% (1.000 ppm)* |
0,1 Vol.-% (1.000 ppm)** |
2 |
medium |
0,5 Vol.-% (5.000 ppm)* |
0,5 Vol.-% (5.000 ppm)** |
3 |
large |
1,0 Vol.-% (10.000 ppm)* |
1,0 Vol.-% (10.000 ppm)** |
* Up to 50 times the OEL with half mask / max. 2,000 x limit with full face mask.
** Max 30 times the OEL with half mask / max. 400 x limit with full face mask.
The values ??correspond to the specified sources. Other national or local regulations must be observed.