Dräger X-plore® Rd40 filter

Filter for all available on the market half and full face masks with a respirator in accordance with EN 148-1

ADVANTAGES:
  • aluminum housing
    • for extra safety: easily detected, filter damage
  • Individually packed and resealable
    • for optimum protection and longer service
    • each with instructions for use
  • Maximum protection through extensive types of filter program
    • optimal protection against almost all hazardous substances - including CO and radioactive iodomethane
  • Filters also available as X-tended version
    • 30% higher service life compared to standard requirements

Shipping weight: 0,20 Kg
Dimensions: × × cm
variation label Filter characterizing color special
gas filter
A 1140 AXB2 brown, gray
B 1140 A2B2E2K2 brown, gray, yellow, green
combination filter
C 1140 A2B2E2K2 Hg P3 R D brown, gray, yellow, green, white, red
D 1140 A1B2E2K1 Hg NO CO 20 P3 R D brown, gray, yellow, green, white, red, black, blue
E 1140 A2B2E2K2 Hg NO CO 20 P3 R D brown, gray, yellow, green, white, red, black, blue
F 1140 A2 P3 R D / Reaktor brown, orange, white incinerable



characterizing color Filter type Main areas of application
Brown AX1) Gases and vapors of organic compounds, boiling point < 65 °C
Brown A Gases and vapors of organic compounds, boiling point > 65 °C
Gray B inorganic gases and vapors, such as chlorine, hydrogen sulfide, hydrogen cyanide (HCN)
Yellow E Sulfur dioxide, hydrogen chloride
Green K ammonia
Black CO2) carbon monoxide
Red Hg3) mercury vapor
Blue NO4) nitrous gases, including nitric oxide
Orange Reaktor radioiodine, including radioactive iodomethane
White P particle


1) AX-filter may be used only in the delivery state (factory fresh). Reuse and use against gas mixtures is absolutely inadmissible.
2) CO filter may be used only once and must be disposed of after use.
3) Hg filters may acc. EN 14387 for max. 50 hours are used.
4) NO filter may be used only once and must be disposed of after use.

filter class capacity/
Separation efficiency
Maximum allowable concentration of pollutants
(according to EN Report 529, EN 14387)
Maximum allowable concentration of pollutants
(according to BGR 190, EN 14387)
particulate filter
1 small 4 x Limit with half mask
5 x Limit with full face mask
4 x Limit with half mask
4 x Limit with full face mask
2 medium 12 x Limit with half mask
16 x Limit with full face mask
10 x Limit with half mask
15 x Limit with full face mask
3 large 48 x Limit with half mask
1.000 x Limit with full face mask
30 x Limit with half mask
400 x Limit with full face mask
gas filters
1 small 0,1 Vol.-% (1.000 ppm)* 0,1 Vol.-% (1.000 ppm)**
2 medium 0,5 Vol.-% (5.000 ppm)* 0,5 Vol.-% (5.000 ppm)**
3 large 1,0 Vol.-% (10.000 ppm)* 1,0 Vol.-% (10.000 ppm)**


* Up to 50 times the OEL with half mask / max. 2,000 x limit with full face mask.
** Max 30 times the OEL with half mask / max. 400 x limit with full face mask.