WTW Conductivity Cells TetraCon®

Item number: WTW_Z0016

EAN: 4064343255806

Category: WTW

Manufacturer: WTW

starting from 428,00 €

Excluding 19% VAT. , plus shipping (Standard Light)

(including 19% VAT. 509,32 €)
conductivity cell

There are variations of this item. Please select the variation you wish.


WTW Conductivity Cells TetraCon®

In comparison with conventional measuring cells with 2 electrodes, the TetraCon® conductivity cell offers numerous technical advantages:
  • Highest degree of precision and linearity by optimized cell geometry
  • Extremely large measuring range with just one cell
  • Long-term cell constant stability with high-quality abrasion-resistant graphite electrodes
  • With built-in temperature probe
  • Smallest immersion depth possible
  • No measuring errors even with very dirty electrodes - contact resistance on the electrode surface is automatically compensated
  • No measuring errors from cable influences
  • No measuring errors from primary or secondary polarization effects
  • No measuring errors due to contact with side walls or base of measuring vessels
  • Robust, unbreakable epoxy body

Shipping weight: 0,50 Kg
KLE 325 TetraCon® 325
TetraCon® V
TetraCon® 325/S LR 325/01
LR 01 V
LR 325/001 TetraCon® DU/T **
Application Standard Universal Special Ultrapure Water Trace Flow-through
Electrode material Graphite Graphite Graphite V4A steel V4A steel Graphite
Flow-through vessel - - - - V4A steel -
Shaft material Epoxy Epoxy Epoxy V4A steel V4A steel Epoxy
Shaft length 120 mm 120 mm 120 mm 120 mm 120 mm 155 mm
Cell constant K = 0.84 cm-1 K = 0.475 cm-1 K = 0.491 cm-1 K = 0.1 cm-1 K = 0.01 cm-1 K = 0.778 cm-1
Diameter 15.3 mm 15.3m 15.3 mm 12 mm 20 mm -
Cable length 1.5 m 1.5 m 1.5 m 1.5 m 1.5 m 1 m (only with KKDU 325)
Measuring range 1 µS/cm...20 mS/cm 1 µS/cm...2 S/cm* 1 µS/cm ... 2 S/cm* 0,001 µS/cm...200 µS/cm 0,0001 µS/cm...30 µS/cm 1 µS/cm...2 S/cm*
Temperature range 0...80 °C 0...100 °C 0...100 °C 0...100 °C 0...100 °C 0...60 °C
Filling volume - - - 17 ml (without sensor) ca. 10 ml (without sensor) 7 ml
Min./max. Immersion depth 36/120 mm 36/120 mm (TetraCon® 325),
40 mm (TetraCon® V)
40/120 mm 30/120 mm (LR 325/01),
40 mm (LR 01 V)
40/120 mm -

*...Measuring range depends on particular instrument
**...Adapter cable KKDU 325, length 1 m (3.3 ft), is necessary for the connection

MultiLine®: Multi 3410/3420/3430/
inoLab® Multi IDS
ProfiLine
Cond 3110
ProfiLine
Cond 3210/3310
VARIO®
Cond
Cond 315i LF 318 LF 320/323/325 LF 330/340A Cond 330i/340i
KLE 325 + +
LTA 1 2 2 2 2 2
LR 01/T
TetraCon® 325,
TetraCon® 325/C
+ + + + + + +
IDS TetraCon® 925 +
TA 197 LF
TetraCon® DU/T 5 5 5 5
TetraCon® DU/TH 5 5 5 5
LR 325/01 + + + + +
IDS LR 925/01 +
LR 325/001 + + +
TetraCon® 325/S + + +
ConOx
TetraCon® V +
LR01 V +

2...Adapter cable K/LTA together with temperature probe TFK 325 or TFK 150
4...Connection cable KKDU
5...Connection cable KKDU 325

< />>MultiLine® P4, Multi 340i,
Multi 197i, Multi 1970i
inoLab® Cond,
pH/Cond, Multi
LF 3000 MultiLab® 540 MultiLine® P3 pH/LF,
pH/Cond 340i
Multi 350i LF 197,
LF 597
Cond 1970i/197i
KLE 325
LTA 1 2 2 2 2
LR 01/T +
TetraCon® 325,
TetraCon® 325/C
+ + + + + + +
IDS TetraCon® 925
TA 197 LF + +
TetraCon® DU/T 5 4 5 5 5 5
TetraCon® DU/TH 5 4 5 5 5 5
LR 325/01 + + + + +
IDS LR 925/01
LR 325/001 + + + +
TetraCon® 325/S + + + + +
ConOx +
TetraCon® V
LR01 V

2...Adapter cable K/LTA together with temperature probe TFK 325 or TFK 150
4...Connection cable KKDU