WTW Conductivity Cells TetraCon®
In comparison with conventional measuring cells with 2 electrodes, the TetraCon® conductivity cell offers numerous technical advantages:
- Highest degree of precision and linearity by optimized cell geometry
- Extremely large measuring range with just one cell
- Long-term cell constant stability with high-quality abrasion-resistant graphite electrodes
- With built-in temperature probe
- Smallest immersion depth possible
- No measuring errors even with very dirty electrodes - contact resistance on the electrode surface is automatically compensated
- No measuring errors from cable influences
- No measuring errors from primary or secondary polarization effects
- No measuring errors due to contact with side walls or base of measuring vessels
- Robust, unbreakable epoxy body
|
KLE 325 |
TetraCon® 325 TetraCon® V |
TetraCon® 325/S |
LR 325/01 LR 01 V |
LR 325/001 |
TetraCon® DU/T ** |
Application |
Standard |
Universal |
Special |
Ultrapure Water |
Trace |
Flow-through |
Electrode material |
Graphite |
Graphite |
Graphite |
V4A steel |
V4A steel |
Graphite |
Flow-through vessel |
- |
- |
- |
- |
V4A steel |
- |
Shaft material |
Epoxy |
Epoxy |
Epoxy |
V4A steel |
V4A steel |
Epoxy |
Shaft length |
120 mm |
120 mm |
120 mm |
120 mm |
120 mm |
155 mm |
Cell constant |
K = 0.84 cm-1
|
K = 0.475 cm-1
|
K = 0.491 cm-1
|
K = 0.1 cm-1
|
K = 0.01 cm-1
|
K = 0.778 cm-1
|
Diameter |
15.3 mm |
15.3m |
15.3 mm |
12 mm |
20 mm |
- |
Cable length |
1.5 m |
1.5 m |
1.5 m |
1.5 m |
1.5 m |
1 m (only with KKDU 325) |
Measuring range |
1 µS/cm...20 mS/cm |
1 µS/cm...2 S/cm* |
1 µS/cm ... 2 S/cm* |
0,001 µS/cm...200 µS/cm |
0,0001 µS/cm...30 µS/cm |
1 µS/cm...2 S/cm* |
Temperature range |
0...80 °C |
0...100 °C |
0...100 °C |
0...100 °C |
0...100 °C |
0...60 °C |
Filling volume |
- |
- |
- |
17 ml (without sensor) |
ca. 10 ml (without sensor) |
7 ml |
Min./max. Immersion depth |
36/120 mm |
36/120 mm (TetraCon® 325), 40 mm (TetraCon® V) |
40/120 mm |
30/120 mm (LR 325/01), 40 mm (LR 01 V) |
40/120 mm |
- |
*...Measuring range depends on particular instrument
**...Adapter cable KKDU 325, length 1 m (3.3 ft), is necessary for the connection
|
MultiLine®: Multi 3410/3420/3430/ inoLab® Multi IDS |
ProfiLine Cond 3110 |
ProfiLine Cond 3210/3310 |
VARIO® Cond |
Cond 315i |
LF 318 |
LF 320/323/325 |
LF 330/340A |
Cond 330i/340i |
KLE 325 |
|
+ |
+ |
|
|
|
|
|
|
LTA 1 |
|
|
2 |
|
|
2 |
2 |
2 |
2 |
LR 01/T |
|
|
|
|
|
|
|
|
|
TetraCon® 325, TetraCon® 325/C |
|
+ |
+ |
|
+ |
+ |
+ |
+ |
+ |
IDS TetraCon® 925 |
+ |
|
|
|
|
|
|
|
|
TA 197 LF |
|
|
|
|
|
|
|
|
|
TetraCon® DU/T |
|
|
5 |
|
|
|
5 |
5 |
5 |
TetraCon® DU/TH |
|
|
5 |
|
|
|
5 |
5 |
5 |
LR 325/01 |
|
|
+ |
|
+ |
|
+ |
+ |
+ |
IDS LR 925/01 |
+ |
|
|
|
|
|
|
|
|
LR 325/001 |
|
|
+ |
|
|
|
|
+ |
+ |
TetraCon® 325/S |
|
|
+ |
|
|
|
|
+ |
+ |
ConOx |
|
|
|
|
|
|
|
|
|
TetraCon® V |
|
|
|
+ |
|
|
|
|
|
LR01 V |
|
|
|
+ |
|
|
|
|
|
2...Adapter cable K/LTA together with temperature probe TFK 325 or TFK 150
4...Connection cable KKDU
5...Connection cable KKDU 325
|
inoLab® Cond, pH/Cond, Multi |
LF 3000 |
MultiLab® 540 | < />>MultiLine® P4, Multi 340i,
Multi 197i, Multi 1970i
MultiLine® P3 pH/LF, pH/Cond 340i |
Multi 350i |
LF 197, LF 597 |
Cond 1970i/197i |
KLE 325 |
|
|
|
|
|
|
|
|
LTA 1 |
2 |
|
|
|
2 |
2 |
|
2 |
LR 01/T |
|
+ |
|
|
|
|
|
|
TetraCon® 325, TetraCon® 325/C |
+ |
|
+ |
+ |
+ |
+ |
+ |
+ |
IDS TetraCon® 925 |
|
|
|
|
|
|
|
|
TA 197 LF |
|
|
|
|
|
|
+ |
+ |
TetraCon® DU/T |
5 |
4 |
5 |
|
|
5 |
5 |
5 |
TetraCon® DU/TH |
5 |
4 |
5 |
|
|
5 |
5 |
5 |
LR 325/01 |
+ |
|
+ |
|
|
+ |
+ |
+ |
IDS LR 925/01 |
|
|
|
|
|
|
|
|
LR 325/001 |
+ |
|
+ |
|
|
+ |
|
+ |
TetraCon® 325/S |
+ |
|
+ |
|
|
+ |
+ |
+ |
ConOx |
|
|
|
|
|
+ |
|
|
TetraCon® V |
|
|
|
|
|
|
|
|
LR01 V |
|
|
|
|
|
|
|
|
2...Adapter cable K/LTA together with temperature probe TFK 325 or TFK 150
4...Connection cable KKDU
5...Connection cable KKDU 325