BOD Self-check Measurement - for a larger number of samples, with easy sample management 
  • Controller-driven
  • Simultaneous measurement of up to 100 samples
  • Statistical evaluation
  • Automatic sample ID

Complete package for 6 or 12 simultaneous measurements
OxiTop® Control system uses software-controlled functions and infrared interface to communicate with the powerful OC 100 controller. This connection enables the simultaneous, group start, management, storage and tracking of 100 measuring heads, and tracks results on a large graphic display. Data can be transferred to the PC for evaluation and documentation via the AK-540/B cable and the communication program Achat OC. The OC 110 controller, in combination with the OxiTop® Control S6 / S12, is ideal when other applications in addition to BOD are required.

Check sampling progress
The data can be called up at any time, even during sampling, thus enabling checking of the samples for errors. The display of the progress curve allows immediate detection of irregularities and interferences, such as a BOD value set too high for the volume used or undesired nitrification. Corrections can thus be made at an early stage.

Controller OC 100 / OC 110
Features
  • Simultaneous sample management with option of grouping up to 100 OxiTop®-C measuring heads.
  • Data call-up of one parallel sample with statistical evaluation and as individual data.
  • Automatic calculation and graphical display of BOD value.
  • Data transfer even through glass doors.
  • Protocol and documentation of data via Achat OC communication program in combination with a PC.
  • GLP and AQS with inspection intervals for calibration with the OxiTop® PM calibration tablets.


OxiTop®-C Measuring Head
  • Instead of the usual display and keys, the OxiTop®-C measuring head has an infrared interface with which it communicates with Controller OC 100 or OC 110. By pointing the controller at an OxiTop®-C measuring head the sample can be identified and the measurement is started. Data can be called up or deleted and sampling progress can be displayed.
  • Each sample is automatically assigned a unique ID number; eliminating manual sample identification even for multiple samples. In addition, statistical evaluations can be easily performed for multiple samples.
  • The OxiTop®-C measuring heads have an AutoTemp function; if the sample temperature is too cold, the start of measurement is automatically delayed, by up to 4 hours, until a constant temperature can be reached. This mode can be deactivated for BOD standard.
  • The measuring heads can store up to 360 data sets. Data are automatically stored in the corresponding interval according to the interval period set (0.5 h to 99 days).
  • The built-in pressure sensor can register differences in pressure ranging from 500 to 1,350 hPa.

Analytical device: BSB measuring device
Width (Analytical instruments): 100 mm
Height (Analytical equipment): 45 mm
Depth (Analytical instruments): 200 mm
Shipping weight: 5,00 Kg

WTW OxiTop® Control 6 / 12
Vessel with measuring head Amber bottle, 510 ml with rubber sleeve
Number 6 / 12
Measuring heads OxiTop®-C
Stirrer IS 6 / IS 12
Controller OC 100
Software + cable -
CO2 absorbent +
Nitrification inhibitor +
Overflow measuring flask 164 / 432 ml
Stirrer bars 6 / 12
Stirrer bar remover +
Blocks of chart paper +

Technical data OxiTop® Control OC 100
BOD routine Individual samples up to 4,000 mg/l
BOD standard Multiple samples with statistical evaluation up to 4,000 mg/l
BOD special -
Soil respiration -
OECD / Aerobic applications -
Biogas determination -
Data sets per measurement 180...360 (depending on duration)
Measurement period 0.5 h...99 days
Power supply 3 mignon (AA); alkaline 1.5 V
Interface IR (infrared); RS 232 for communication with PC
Ambient temperature Storage: -25 °C...+65 °C (-13 °F...149 °F), Operations: +5 °C...+40 °C (41 °F...104 °F)
Dimensions 45 x 100 x 200 mm (1.7 x 3.9 x 7.9 in) (H x W x D)
Weight Approx. 390 g (0.86 lb)

Messkopf OxiTop®-C
Measuring principle Manometric with pressure sensor
Measurement of BODn
Pressure range 500 - 1350 hPa
Accuracy ±1% of value ±1 hPa
Resolution 1 hPa (corresponds to 0.7% of BODn measuring range)
Power supply Lithium batteries (280 mAh), 2 x CR2430
Ambient temperature Storage: -25...+65 °C (-13...149 °F)
Operation: +5...+50 °C (41...122 °F)
Dimensions H: 70 mm (2.8 in), Ø 70 mm (2.8 in)

Accessories

WTW Mark-6 marking rings Details
Price on application
WTW OxiTop® AD Adapter Details
Price on application
WTW OxiTop® SET-10 Details
Price on application
WTW OxiTop® SET-2 Details
Price on application
WTW OxiTop® SET-6 Details
Price on application
WTW Stirrers for BOD measurement Details
starting from 932,00 € *

Related products

WTW OxiTop® Control B6/B6M Details
Now only 4.901,05 € *
WTW OxiTop® Control AN6 / AN12 Details
starting from 6.891,30 € *
WTW OxiTop® Control S6 / S12 Details
starting from 4.698,70 € *
WTW OxiTop® Control A6 / A12 Details
starting from 6.192,10 € *
WTW OxiTop® IS 6, IS 12 Details
starting from 2.373,10 € *