Hettich Benchtop centrifuge ROTINA Robotic 380 series

Item number: HETT_22022

EAN: 4064343146418

Category: Hettich

Manufacturer: Andreas Hettich

Price on application
Model / Hatch

There are variations of this item. Please select the variation you wish.


Hettich Benchtop centrifuge ROTINA Robotic 380 series

Hettich robotically operated centrifuges have been performing reliably in the laboratory for more than 20 years. They are used wherever sample processing can be automated, and make a significant contribution to the rationalisation and safety of routine tasks. They enable time-consuming, repetitive process steps to be carried out automatically. This not only minimises the risk of infection, but also allows laboratory personnel to concentrate on other tasks.

Our ROTINA 380 Robotic models are available as air-cooled or cooled benchtop centrifuges and as cooled underbench units. They centrifuge microtitre plates and blood collection tubes fast and reliably.

With the robotically operated ROTINA 380 Robotic and 380 R Robotic, automation has now also found its way onto the laboratory bench. The ROTINA 380 RC Robotic is ideally suited for setting up an automated workstation for routine clinical diagnostics. It can carry out special tasks, such as the centrifugation of STAT samples. The routine workflow therefore does not have to be interrupted when emergency samples are delivered. This relieves the load, particularly at peak times when large numbers of samples have to be processed within the shortest possible time. In the research sector, the ROTINA 380 Robotic models also make a valuable contribution

The ROTINA 380 Robotic is an air-cooled centrifuge with PC control and rotor positioning.

The ROTINA 380 R Robotic is a cooled centrifuge with PC control and rotor positioning.

The ROTINA 380 RC Robotic is an underbench centrifuge with PC control and rotor positioning.

EASE OF USE
Automatic, safe and precise: A robot arm loads and unloads the centrifuge. A hatch in the lid, through which the robot arm reaches into the centrifuging chamber, opens automatically before and after each centrifugation.
All centrifuge functions can be controlled by means of a PC. In addition, the advanced C-controller enables
  • automatic checking of the operation of all important components
  • interrogation of status information
  • programming of carrier position, positioning accuracy: < 0.6 mm
SAFETY
  • Lid locking
  • Run cycle counter
  • Motor overheating protection
  • Chamber overheating protection (in units with cooling)
  • Imbalance switch-off
  • Overtemperature protection of braking resistor
  • Rotor recognition
  • Monitoring of information transmission
  • Option: Photoelectric sensors in the hatch (with ROTINA 380, 380 R, 380 RC Robotic)
The robust and solid design ensures fault-free operation 24 hours a day

Hettich centrifuges and their accessories can be tailored for numerous applications. No matter how special your requirements, the carriers and adapters of our robotic centrifuges can be matched exactly to the geometry of the robot and the grip arm.

The standard accessories for the ROTINA 380 Robotic models include two swing-out rotors with suitable carriers.

Dimensions (H x W x D) (centrifuges): 477 x 470 x 579 mm477 x 680 x 579 mm622 x 470 x 579 mm
Connection value (centrifuges): 650 VA1300 VA
Speed max.: 5100 rpm
Frequency (Centrifuges): 50/60 Hz
Weight approx. (centrifuges): 81 kg113 kg120 kg
Capacity/capacity max.: 48 blood collection tubes, 10 micro titer plates
Cooling (Centrifuges): with coolingwithout coolingInfinitely variable from -20 °C to +40 °C
Cooling, heating: heatingcooling
hatch: Rear hatchfront hatch
RCF max.: 4696 xg
Rotor type: swing-out rotor
Voltage (centrifuges): Can be operated at different voltages, Units are fitted with a transformer
Centrifuge type: small centrifuge
Permissible density of the sample material: 1.2 kg/dm3
Hettich Centrifuge ROTINA 380 Robotic ROTINA 380 R Robotic ROTINA 380 RC Robotic
without cooling with cooling with cooling
Rear hatch/front hatch Rear hatch/front hatch Rear hatch/front hatch
Voltage Can be operated at different voltages. Units are fitted with a transformer.
Frequency 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz
Consumption 460 VA 1.300 VA 1.300 VA
Max. capacity 48 blood collection tubes,
10 micro titer plates
48 blood collection tubes,
10 micro titer plates
48 blood collection tubes,
10 micro titer plates
Max. speed (RPM) 5.100 min-1 5.100 min-1 5.100 min-1
Max. RCF 4.696 4.696 4.696
Permissible density of the sample material 1.2 kg/dm3 1.2 kg/dm3 1.2 kg/dm3
Dimensions (H x W x D 477 x 470 x 579 mm 477 x 680 x 579 mm 622 x 470 x 579 mm
Weight
approx. 81 kg
approx. 113 kg
approx. 120 kg