Hettich Benchtop centrifuge ROTOFIX 32 A

Item number: HETT_22009

EAN: 4064343149471

Category: Centrifuges, Centrifuges with vortex function

Manufacturer: Andreas Hettich

starting from 2.146,00 €

Excluding 19% VAT. , plus shipping (Standard 2500)

(including 19% VAT. 2.553,74 €)


Hettich ROTOFIX 32 A benchtop centrifuge

The Hettich ROTOFIX 32 A bench-top centrifuge is designed for a wide range of routine and special tasks in clinical, pharmaceutical and life science laboratories. Its particularly high flexibility in the selection of rotors enables numerous separation processes to be carried out - from blood and DNA analysis to the preparative processing of suspensions and emulsions. Compared to other laboratory centrifuges, this model features a sophisticated safety concept, modern microprocessor control and exceptionally high durability with low maintenance requirements. Laboratory users benefit from reliable, precise performance control and great intuitive ease of use. Versatility and strong technical performance for everyday laboratory use

The ROTOFIX 32 A was specially developed to meet the diverse requirements of professional laboratories. Thanks to modular selectable rotors - including free-swing and angle rotors - a wide variety of sample vessels and loadings can be accommodated. The robust design and high-quality components ensure reproducible results and a long service life, even during continuous operation.

Key technical features at a glance:

  • Maximum speed: 6,000 rpm for efficient separation of even the smallest particles
  • Maximum RCF: Up to 4,226 x g - ideal for DNA/RNA preparation, cell diagnostics or protein analysis
  • Maximum capacity in swing-out rotor: 4 x 100 ml, in angle rotor 6 x 85 ml - flexible for different sample sizes
  • Operating modes: Time control from 1 second to 99 minutes 59 seconds, continuous operation or short run (pulse mode)
  • Dimensions (H x W x D): 257 x 366 x 430 mm; weight: approx. 23 kg - compact with high capacity for tabletop operation
  • Connection values: 208 - 240 V, 50/60 Hz, 300 VA - can be used with all standard laboratory power cables
  • Certifications: Compliant with EN/IEC 61326-1, Class B; IVD Directive 98/79/EC - for the highest safety and quality standards

One highlight is the user-friendly digital control panel, which allows precise control of all running parameters. Microprocessor technology ensures extremely stable speed maintenance and reproducible separation performance. Operation is made particularly safe by the integrated monitoring system, which reports any malfunctions or imbalances in real time and initiates protective measures. The integrated energy-saving air cooling system ensures reliable operation even during continuous use without the need for refrigerant replacement.

Available rotors (selection):

  • Swing-out rotor for 4 × 100 ml (90°), max. RCF 2,630
  • Swing-out rotor for 8 × 50 ml (45°), max. RCF 2,469
  • Angle rotor for 6 × 85 ml, max. RCF 4,226

The selection of suitable rotors and adapters opens up a wide range of possibilities, from standard blood sampling and tissue homogenisation to the processing of special sample volumes in research and clinical diagnostics.

Certifications & Standards

The centrifuge meets the following requirements:

  • EN / IEC 61326-1, Class B (electromagnetic compatibility)
  • CE marking
  • IVD Directive 98/79/EC (in vitro diagnostics) This makes it ideal for diagnostic use in the medical field and for laboratory operations in accordance with current quality standards.

Specific practical application examples

  • Clinical diagnostics: Separation of blood plasma, serum or urine for routine tests and special analyses.
  • Blood banks: Production and purification of erythrocyte, thrombocyte or plasma fractions.
  • Molecular biology: Isolation of DNA and RNA from cell lysates and tissue samples.
  • Pharmaceutical development: Separation of suspensions such as protein precipitates or cell cultures.

Typical substances: EDTA blood, heparin blood, serum samples, cell culture supernatants, plasma samples, DNA extracts.

Thanks to the flexible rotor options, it can be used across laboratories - from hospital laboratories to private research institutes.

Frequently asked questions (FAQ)

What sample types and volumes can be processed?

  • The centrifuge is designed for 50 ml, 85 ml and 100 ml sample tubes and can hold up to 4 x 100 ml (swing-out rotor) or 6 x 85 ml (angle rotor).

Is there automatic imbalance detection?

  • Yes, the system continuously monitors for possible imbalance and interrupts operation to prevent damage and ensure operational safety.

Is operation intuitive?

  • Yes, the digitally controlled control panel with plain text display makes it easy to select the time, speed and rotor - even for changing applications.

How is the centrifuge cooled?

  • The device operates with low-maintenance air cooling, which ensures a constant temperature even during continuous operation.

Which rotors are suitable for the most important routine tasks?

  • The swing-out rotor for 4 x 100 ml is suitable for standard separations in clinics, while the angle rotor for 6 x 85 ml is the preferred choice for molecular biology applications.

Does the device require regular maintenance?

  • The ROTOFIX 32 A is designed for low maintenance; regular cleaning and occasional inspection of the rotors and bearings is usually sufficient.

Does the centrifuge comply with current standards for medical devices?

  • It is certified according to EN/IEC 61326-1, bears the CE mark and is IVD-compliant according to 98/79/EC.

Conclusion

The ROTOFIX 32 A is a powerful, universally applicable benchtop centrifuge for demanding laboratory tasks. It features a wide range of rotors, precise microprocessor control and comprehensive operational safety. Suitable for clinics, diagnostics, pharmaceuticals or research, it maximises efficiency in routine and special applications and meets the highest standards of quality, reliability and flexibility.


Dimensions (H x W x D) (centrifuges): 257 x 366 x 430 mm
Connection value (centrifuges): 300 VA
Speed max.: 6000 rpm
Frequency (Centrifuges): 50/60 Hz
Capacity of vessels: 50 ml85 ml100 ml
Weight approx. (centrifuges): 23 kg
Frequently used rotors: Swing-out rotor for 4 x 100 ml (90°), max. RCF 2.630Swing-out rotor for 8 x 50 ml (45°), max. RCF 2.469Angle rotor for 6 x 85 ml, max. RCF 4.226
Capacity/capacity max.: 4 x 100 ml (in a swing-out rotor)6 x 85 ml (in an angle rotor)
Cooling (Centrifuges): Air cooling
Duration: 1 sec - 99 min : 59 sec, continuous run, short cycle mode
Product registrations: IVD compliant 98/79/EC
RCF max.: 4226 xg
Rotor type: angle rotorswing-out rotorCyto-rotor
Voltage (centrifuges): 208 - 240 V
Interference emission, interference immunity: EN / IEC 61326-1, class B
Centrifuge type: small centrifuge
Shipping weight: 14,48 Kg
Product weight: 10,98 Kg
Hettich Benchtop centrifuge ROTOFIX 32 A
Power supply *) 208 - 240 V 1 ~
Frequency 50 - 60 Hz
Consumption 300 VA
Emission, Immunity EN / IEC 61326-1, class B
Max.capacity
in a swing-out rotor 4 x 100 ml
in an angle rotor 6 x 85 ml
Max. speed 6.000 min-1
Max. RCF 4.226
Running time 1 - 99 min, continuous run,
short cycle mode (impulse key)
Dimensions (H x W x D) 257 x 366 x 430 mm
Weight approx. 23 kg
Cooling Air cooling
Frequently used rotors Swing-out rotor for 4 x 100 ml (90°),
max. RCF 2.630
Swing-out rotor for 8 x 50 ml (45°),
max. RCF 2.469
Angle rotor for 6 x 85 ml,
max. RCF 4.226

*) other voltages on request
Information on product safety
Manufacturer information:
Andreas Hettich GmbH & Co.KG
Föhrenstraße 12
78532 Tuttlingen, Deutschland
[email protected]
Responsible person:
Mr. Schuldt
0049 30 403 667 940
[email protected]
Accessories ROTOFIX 32
  • Accessories ROTOFIX 32
  • Accessories ROTOFIX 32
  • Accessories ROTOFIX 32
  • Accessories ROTOFIX 32
  • Accessories ROTOFIX 32
  • Accessories ROTOFIX 32
  • Accessories ROTOFIX 32
  • Accessories ROTOFIX 32
  • Accessories ROTOFIX 32
  • Accessories ROTOFIX 32
  • Type: Angle rotor (8-place)
  • Maximum permissible load: 8 standard sample tubes
  • Maximum speed: Gravity fields of over 60,000 x g achievable
  • Material: High-quality, corrosion-resistant materials for a long service life
  • Compatibility: Suitable for Hettich benchtop centrifuges, specially designed for blood group serology
  • Certifications: CE mark, ISO-compliant
  • Maintenance: Easy to clean and check for damage or wear
  • The rotor enables the separation of blood components, cell fractions and other biological samples under reproducible conditions. It is designed for speeds required for most serological and diagnostic centrifugation applications and can be operated with both small and standardised sample tubes.

    A special feature is its outstanding smoothness during the centrifugation process, which ensures sample integrity in daily use and optimally meets occupational safety requirements (protection against vibrations and noise).

    Certifications and standards

    • CE marking: Compliant with European directives for machine and product safety
    • ISO certification: Production and quality management in accordance with current international standards
    • Meets specific requirements for use in medical and analytical laboratories

    Compliance with these standards ensures safety during installation and operation, reduces liability risks and guarantees consistently high quality in every application.

    Specific examples of laboratory applications

    • Blood group serology: Precise separation of blood components for determining blood groups and antibody patterns. Suitable for erythrocyte suspensions and antibody detection.
    • Clinical chemistry: Sedimentation of urine, plasma or serum samples in preparation for subsequent analyses, e.g. detection of creatinine, glucose or proteins.
    • Molecular biology applications: Separation of cell lysates or cell nuclei during DNA/RNA isolation with specific buffers and buffer additives.
    • Microbiological diagnostics: Sedimentation of bacteria, yeasts or cell cultures for further identification or antibiogram determination.

    The angle rotor is compatible with a wide range of standard sample tubes, including EDTA, citrate or heparin tubes. It also ensures efficient working with sensitive substances such as enzyme-containing solutions or serum preparations.

    FAQs

    Installation and commissioning

    How is the rotor installed correctly?

    • Place the rotor centrally on the rotor shaft of the appropriate Hettich bench centrifuge and secure it with the screw provided. Detailed instructions can be found in the centrifuge operating manual.

    Suitable sample vessels

    Which tubes are compatible?

    • Suitable for all standard tubes used in blood group serology and bioscience research (e.g. 5-10 ml tubes with fixed or removable caps).

    Cleaning and maintenance

    How should cleaning be carried out?

    • Clean the rotor after each use with a mild laboratory cleaner and water, rinse thoroughly and leave to dry. Aggressive cleaning agents or abrasives should be avoided.

    Service life and inspection interval

    How often should the rotor be checked?

    • It is recommended to check for microcracks and material fatigue before each use. An annual check by qualified maintenance personnel extends the service life and ensures operational safety.

    Conclusion

    The Hettich 8-place angle rotor for benchtop centrifuges provides professional users with a reliable, high-performance rotor accessory that creates optimal centrifugation conditions for a wide range of laboratory applications. Excellent material quality, high maximum centrifugation force and versatile compatibility make this model the first-class choice for demanding analysis in research and routine applications. Compliance with relevant standards also ensures long-term, safe and value-adding use.