Hettich Benchtop centrifuge ROTOFIX 46 - ProfiLab24 GmbH
99
100
24
4
stars -
Professional service
Customer
Young team with a lot of ambition and quick answers to all questions. We needed a complete laboratory equipment for our new location. The team of Profiab24 has arranged everything.
Hettich Benchtop centrifuge ROTOFIX 46
4.221,00 €
Excluding 19% VAT. ,
plus
(Sperrgut)
(including 19% VAT. 5.022,99 €)
Hettich Benchtop centrifuge ROTOFIX 46. Order at ProfiLab24 Online catalog for laboratory equipment. Top service. Secure payment.
- Model
-
Hettich Benchtop centrifuge ROTOFIX 46 Centrifuges for use in research and industrial laboratories should ideally be robust and able to cope with the demands of such environments, and have a wide range of accessories for routine applications. They should also enable solutions for special situations. They must therefore be able to hold special sample tubes and in many cases enable the temperature of the samples to be controlled.
Suitable tubes for this application are those designed to meet the requirements of the American Society for Testing Materials (ASTM).
The sulphuric acid content of chrome baths can be determined by using chrome bath tubes. The method, which is intended to provide quality assurance information, is not only of interest to public and private test bodies, but also for the operators of the baths who wish to carry out the regularly necessary sulphate determinations themselves.
Angle rotor (6 place, for Schlenk tubes) is suited for centrifuging Schlenk tubes widely used in organometallic chemistry and coordination complex chemistry. Substances that have been prepared in Schlenk tubes can also be separated in them through centrifugation where necessary.
The ROTOFIX 46 offers various features to make operation easier, such as:
- Rotary opening mechanism so that the centrifuge can be easily opened and closed
- Ergonomic operating and information panel
- 10 programmable memories
- The parameter combination last selected is retained after the centrifuge is switched off
- After entry of the rotor radius r in mm it is possible to switch between display of rpm and the relative centrifugal force (RCF) by pressing the RCF button
- The parameters can be rapidly entered and changed using the rotary button
The ROTOFIX 46 contributes to safety in the workplace. This centrifuge offers the following safety features:
- Lid locking and latching mechanism
- Automatic rotor recognition
- Imbalance switch-off
- Emergency lid release
- Lid dropping prevention mechanism
- Motor overheating protection
- Chamber overheating protection
This compact centrifuge has attractive design features such as:
- Metal casing
- Metal lid
- Centrifugation chamber made of rust-free stainless steel
- View port in the lid
Advantages ROTOFIX 46:
- This centrifuge can be used for special applications such as the quality testing of chrome baths.
- The centrifuge rotors can hold special tubes such as ASTM tubes, Schlenk tubes and chrome bath tubes.
- Simple to use thanks to the ergonomic control and information panel.
- Automatic rotor recognition
- Reliable lid locking
As their designated purpose is for general laboratory use only, the ROTOFIX 46 and 46 H are no medical products according to the IvD Directive. These centrifuges must, therefore, not be used for medical analyses or diagnostic purposes (clinical chemistry) within the scope of the IvD Directive.
Note: Rotor is not included in scope of delivery. Please order separately!
Dimensions (H x W x D) (centrifuges):
|
345 x 538 x 647 mm
|
Connection value (centrifuges):
|
460 VA
|
Speed max.:
|
4000 rpm
|
Frequency (Centrifuges):
|
50/60 Hz
|
Capacity of vessels:
|
100 ml290 ml
|
Weight approx. (centrifuges):
|
58 kg
|
Frequently used rotors:
|
Angle rotor for 6 x 25 or 50 ml Schlenk tubes (45°), max. RCF 805Swing-out rotor for max. 4 x 290 ml (90°), max. RCF 3.095Swing-out rotor for 6 x 30 ml chrome bath tubes (90°), max. RCF 917
|
Capacity/capacity max.:
|
4 x 290 ml (in a swing-out rotor)
|
Cooling (Centrifuges):
|
Air cooling
|
Duration:
|
1 sec - 99 min : 59 sec, continuous run, short cycle mode
|
Product registrations:
|
General laboratory equipment 2014/35/EU
|
RCF max.:
|
3095 xg
|
Rotor type:
|
swing-out rotorangle rotor
|
Voltage (centrifuges):
|
200 - 240 V
|
Interference emission, interference immunity:
|
EN / IEC 61326-1, class B
|
Centrifuge type:
|
small centrifuge
|
Shipping weight: |
78,00 Kg |
Product weight: |
58,00 Kg |
Hettich Benchtop centrifuge |
ROTOFIX 46, classic |
ROTOFIX 46 H, heated |
Power supply *) |
200 - 240 V 1 ~ |
200 - 240 V 1 ~ |
Frequency |
50 - 60 Hz |
50 - 60 Hz |
Consumption |
460 VA |
600 VA |
Emission, Immunity |
EN / IEC 61326-1, class B |
FCC class B |
Max. Capacity
|
|
|
in a swing-out rotor |
4 x 290 ml |
4 x 100 ml |
Max. speed (RPM) |
4.000 min-1
|
2.000 min-1
|
Max. RCF |
3.095 |
984 |
Running time |
1 sec - 99 min : 59 sec, continuous run, short cycle mode (impulse key) |
1 sec - 99 min : 59 sec, continuous run, short cycle mode (impulse key) |
Dimensions (H x W x D) |
345 x 538 x 647 mm |
345 x 538 x 647 mm |
Weight |
approx. 58 kg |
approx. 58 kg |
Temperature |
Air cooling |
Temperature setting, infinitely variable (dependent on the ambient temperature) can be heated up to + 90 °C |
Frequently used rotors |
Angle rotor for 6 x 25 or 50 ml Schlenk tubes (45°), max. RCF 805 |
Angle rotor for 6 x 25 or 50 ml Schlenk tubes (45°), max. RCF 805 |
|
Swing-out rotor for 6 x 30 ml chrome bath tubes (90°), max. RCF 917 |
Swing-out rotor for 6 x 30 ml chrome bath tubes (90°), max. RCF 917 |
|
Swing-out rotor for max. 4 x 290 ml (90°), max. RCF 3.095 |
- |
*) other voltages on request