BINDER Constant climate chamber KBF LQC 240 - ProfiLab24 GmbH
99
100
24
4
stars -
Professional service
Customer
Young team with a lot of ambition and quick answers to all questions. We needed a complete laboratory equipment for our new location. The team of Profiab24 has arranged everything.
BINDER Constant climate chamber KBF LQC 240
Item number: S-152
EAN: 4064343073721
Manufacturer:
Binder
28.583,00 €
Manufacturers suggested retail price:
28.583,00 €
Excluding 19% VAT. ,
plus
(Sperrgut)
(including 19% VAT. 34.013,76 €)
BINDER Constant climate chamber KBF LQC 240. Order online at ProfiLab24 .com with top advice and 24/7 service. Fast delivery. Secure payment.
- Power supply
-
There are variations of this item. Please select the variation you wish.
BINDER Constant climate chamber KBF LQC 240Constant climate chambers with ICHcompliant light source and light dose control
The main advantage of the BINDER KBF LQC series is the patented light photometry for photostability tests. Two 3D spherical sensors control the light dosage of UV-A and visible light. Once the desired light dosage is achieved, the chamber switches off automatically.
BENEFITS
- Homogeneous climate conditions thanks to APT.line technology
- Automatic water and wastewater management
- Pressure humidification with fast response times
- Variable position and removable illumination cassettes
- ICH-compliant illumination for long-term stable test conditions
- Precise photometry with 3D ball-type sensors at the sample
MAIN FEATURES
- Temperature range: 0 °C to 70 °C
- Temperature range with light: 10 °C to 60 °C
- Humidity range: 10 % to 80 % RH
- 2 positionable illumination cassettes with ICH-compliant UV/Vis light source
- Independent light-dose control of UV-A and visible light with spherical sensors
- APT.line preheating chamber technology
- Humidity regulation with capacitive humidity sensor and vapor humidification
- Inner chamber made of stainless steel
- Intuitive touchscreen controller with time-segment and real-time programming with internal data recording
- Tight-sealing inner door made of safety glass (ESG) with special TIMELESS coating
- 2 stainless steel racks
- Access port with silicone plug, 30 mm, left
- 4 stable castors, two with brakes
- Class 3.1 independent temperature safety device (DIN 12880) with visual and audible temperature alarm
- Computer interface: Ethernet
- Door heating
Load max.:
|
51 - 100 kg
|
Width outside (incubators,...):
|
925 mm
|
Width inside (incubators,...):
|
650 mm
|
Maximum temperature (heat):
|
+ 70 °C
|
Height outside (incubators,...):
|
1460 mm
|
Height inside (incubators,...):
|
785 mm
|
Interior volume:
|
201 - 300 l
|
Cabinet type:
|
constant climate chamberclimate chamber
|
Depth outside (incubators,...):
|
800 mm
|
Depth inside (incubators,...):
|
485 mm
|
Lowest temperature (cooling):
|
0 °C
|
BINDER Climate chamber |
KBF LQC 240-230V1) |
KBF LQC 240UL-240V1) |
Performance Data Temperature |
|
|
Temperature range with 100% illumination [°C] |
10...60 |
10...60 |
Temperature range without illumination cassettes [°C] |
0...70 |
0...70 |
Max. heat compensation at 40 °C with illumination [W] |
400 |
400 |
Performance Data Climate |
|
|
Temperature range with 100% illumination [°C] |
10...60 |
10...60 |
Temperature range without illumination cassettes [°C] |
10...70 |
10...70 |
Temperature variation with illumination at 25 °C and 60 % RH [± K] |
0.6 |
0.6 |
Temperature variation with illumination at 40 °C and 75 % RH [± K] |
0.6 |
0.6 |
Temperature fluctuation with illumination at 25 °C and 60 % RH [± K] |
0.2 |
0.2 |
Temperature fluctuation with illumination at 40 °C and 75 % RH [± K] |
0.2 |
0.2 |
Humidity range with illumination cassettes, with illumination [% RH] |
10...75 |
10...75 |
Humidity range without illumination [% RH] |
10...80 |
10...80 |
Humidity fluctuation with illumination at 25 °C and 60 % RH [± % RH] |
1.5 |
1.5 |
Humidity fluctuation with illumination at 40 °C and 75 % RH [± % RH] |
2 |
2 |
Humidty recovery time after 30 s door open at 25 °C and 60 % RH with illumination [min] |
4 |
4 |
Humidty recovery time after 30 s door open at 40 °C and 75 % RH with illumination [min] |
6 |
6 |
Lightdata per Illumination Cassettes2) |
|
|
ICH compliant illumination for photo stability testing [lx] |
7500 |
7500 |
ICH compliant illumination for photo stability testing [W/m2] |
1.1 |
1.1 |
Electrical data |
|
|
Rated Voltage [V] |
200...230 |
200...240 |
Power frequency [Hz] |
50/60 |
50/60 |
Nominal power [kW] |
2.4 |
2.4 |
Unit fuse [A] |
16 |
16 |
Phase (Nominal voltage) [ph] |
1 |
1 |
Outer dimensions not incl. fittings and connections |
|
|
Width net [mm] |
925 |
925 |
Height net [mm] |
1460 |
1460 |
Depth net [mm] |
800 |
800 |
Wall clearance back [mm] |
100 |
100 |
Wall clearance sidewise [mm] |
100 |
100 |
Doors |
|
|
Inner doors |
1 |
1 |
Unit doors |
1 |
1 |
Internal Dimensions |
|
|
Width [mm] |
650 |
650 |
Height [mm] |
785 |
785 |
Depth [mm] |
485 |
485 |
Measures |
|
|
Interior volume [L] |
247 |
247 |
Net weight of the unit (empty) [kg] |
213 |
213 |
permitted load [kg] |
100 |
100 |
Load per rack [kg] |
30 |
30 |
Environment-specific data |
|
|
Energy consumption at 40 °C and 75 % RH [Wh/h] |
760 |
760 |
Sound-pressure level [dB(A)] |
53 |
53 |
Fixtures |
|
|
Number of shelves (std./max.) |
2/7 |
2/7 |
Number of illumination cassettes (std./max.) |
2/2 |
2/2 |
1) All technical data is specified for unloaded units with standard equipment at an ambient temperature of +22 °C ±3 °C and a power supply voltage fluctuation of ±10 %. The temperature data is determined in accordance to BINDER factory standard following DIN 12880, observing the recommended wall clearances of 10 % of the height, width, and depth of the inner chamber. Technical data refers to 100 % fan speed. All indications are average values, typical for units produced in series. We reserve the right to change technical specifications at any time.
2) Average value, measured at 25 °C with a spherical sensor (±10 %) by 12 cm below the light cassette. The values given in W/m2 refer to global radiation.