BINDER Dynamic climate chamber MK 56, 200-230 V 1 ph 50 Hz - ProfiLab24 GmbH
99
100
24
4
stars -
Professional service
Customer
Young team with a lot of ambition and quick answers to all questions. We needed a complete laboratory equipment for our new location. The team of Profiab24 has arranged everything.
BINDER Dynamic climate chamber MK 56, 200-230 V 1 ph 50 Hz in Incubators, Drying Cabinets
Item number: S-154A
EAN: 4064343072212
Manufacturer:
Binder
BINDER Dynamic climate chamber MK 56, 200-230 V 1 ph 50 Hz at ProfiLab24 dealer for laboratory equipment. Made in Germany with top advice and 24H service.
BINDER Dynamic climate chamber MK 56, 200-230 V 1 ph 50 HzDynamic climate chambers for rapid temperature changes
The BINDER MK series chamber is suitable for all heat and cold tests between -40 °C and 180 °C. The MK is a clever alternative to complex individual solutions for cyclical temperature tests.
BENEFITS
- Homogeneous climate conditions thanks to APT.line technology
- Comprehensive programming and data acquisition
- Large heated viewing window
MAIN FEATURES
- Temperature range: -40 °C to 180 °C
- APT.line preheating chamber technology
- Programmable condensation protection for test material
- Heated viewing window with LED interior lighting
- BINDER APT-COM 3 Basic Edition communication software
- Troubleshooting system with visual and audible alarms
- Intuitive touchscreen controller with time-segment and real-time programming with internal data recording
- Access port with silicone plug, 50 mm, left
- 4 castors, two with brakes
- Computer interface: Ethernet
- 230 V power socket on the right-side control panel
- Adjustable ramp function
- Integrated chart recorder
- Real-time clock
- 1 stainless steel rack
- BINDER test confirmation
- Inner chamber made of stainless steel
- Pt 100 temperature sensor
- Thermal insulation using PUR foam
- CFC-free refrigerant R-404A
- Cooling with compressor cooling unit
- Fin evaporator
Load max.:
|
51 - 100 kg
|
Width outside (incubators,...):
|
720 mm
|
Width inside (incubators,...):
|
400 mm
|
Maximum temperature (heat):
|
+ 180 °C
|
Height outside (incubators,...):
|
1445 mm
|
Height inside (incubators,...):
|
420 mm
|
Interior volume:
|
51 - 100 l
|
Cabinet type:
|
climate chamberdynamic climate chamber
|
Depth outside (incubators,...):
|
780 mm
|
Depth inside (incubators,...):
|
348 mm
|
Lowest temperature (cooling):
|
- 40 °C
|
Product weight: |
165,00 Kg |
Dimensions: |
× × cm |
BINDER Dynamic climate chamber |
MK 56-230V1) |
MK 56-240V1) |
Performance Data Temperature |
|
|
Temperature range [°C] |
-40...180 |
-40...180 |
Temperature variation depending on setpoint [± K] |
0.5...1.5 |
0.5...1.5 |
Temperature fluctuation depending on setpoint [± K] |
0.1...0.5 |
0.1...0.5 |
Average heating-up rate according to IEC 60068-3-5 [K/min] |
5.5 |
5.5 |
Cooling down time from 180 °C to -40 °C [min] |
90 |
90 |
Average cooling down time according to IEC 60068-3-5 [K/min] |
5.5 |
5.5 |
Max. heat compensation at 25 °C [W] |
800 |
800 |
Electrical data |
|
|
Rated Voltage [V] |
200...230 |
200...240 |
Power frequency [Hz] |
50 |
60 |
Nominal power [kW] |
2.8 |
2.8 |
Unit fuse [A] |
16 |
16 |
Phase (Nominal voltage) [ph] |
1 |
1 |
Outer dimensions not incl. fittings and connections |
|
|
Width net [mm] |
720 |
720 |
Height net [mm] |
1445 |
1445 |
Depth net [mm] |
780 |
780 |
Wall clearance back [mm] |
300 |
300 |
Wall clearance sidewise [mm] |
200 |
200 |
Viewing window width [mm] |
288 |
288 |
Viewing window height [mm] |
255 |
255 |
Doors |
|
|
Inner doors |
1 |
1 |
Unit doors |
1 |
1 |
Internal Dimensions |
|
|
Width [mm] |
400 |
400 |
Height [mm] |
420 |
420 |
Depth [mm] |
348 |
348 |
Measures |
|
|
Interior volume [L] |
60 |
60 |
Net weight of the unit (empty) [kg] |
165 |
165 |
permitted load [kg] |
60 |
60 |
Load per rack [kg] |
15 |
15 |
Environment-specific data |
|
|
Sound-pressure level [dB(A)] |
59 |
59 |
Fixtures |
|
|
Number of shelves (std./max.) |
1/4 |
1/4 |
1) All technical data is specified for unloaded units with standard equipment at an ambient temperature of +22 °C ±3 °C and a power supply voltage fluctuation of ±10 %. The temperature data is determined in accordance to BINDER factory standard following DIN 12880, observing the recommended wall clearances of 10 % of the height, width, and depth of the inner chamber. Technical data refers to 100 % fan speed. All indications are average values, typical for units produced in series. We reserve the right to change technical specifications at any time.