BINDER FED 400 Heating chamber with mechanical convection

Item number: BIND_6089

EAN: 4064343300544

Category: Incubators, Drying Cabinets

Manufacturer: Binder

6.770,00 €

Manufacturer’s suggested retail price: 6.770,00 €

Excluding 19% VAT. , plus shipping (Sperrgut)

(including 19% VAT. 8.056,29 €)
Power supply

There are variations of this item. Please select the variation you wish.


BINDER FED 400 heating cabinet with forced convection

The BINDER FED 400 heating cabinet with forced convection is a powerful precision device for analytical and medical laboratories, research institutions, and industrial quality control. Its main application is the controlled heating of biological samples, materials and cultures. Thanks to its innovative convection system, this model offers excellent temperature uniformity, making heat treatment faster and more reproducible than with static air units. Users benefit from increased process reliability, flexible control and comprehensive application options compared to other drying chambers in its class.

Powerful technology for demanding laboratory applications

The device impresses with its robust construction, advanced control technology and a sophisticated air circulation system. The advanced air circulation technology guarantees fast heating times and minimised temperature deviations in the interior - key features for standardised analyses and reproducible test results.

Key technical features:

  • Interior volume: 400 litres - offers generous working space for a wide range of applications
  • Temperature range: 5 °C above room temperature to 300 °C, suitable for a wide range of laboratory protocols
  • Uniform temperature distribution: Spatial temperature deviation at 70 °C only ±1 K, at 150 °C ±2.5 K, at 300 °C ±4.8 K
  • Heating time: 18 minutes to 70 °C, 35 minutes to 150 °C, 60 minutes to 250 °C
  • Electronic fault self-diagnosis system with visual and audible alarm
  • Control module with real-time clock, parallel display of all relevant parameters and Ethernet interface for APT-COM DataControlSystem software
  • Load capacity: Up to 90 kg total load (maximum 35 kg per shelf), numerous stainless steel shelves can be retrofitted
  • Energy efficiency: Consumption at 70 °C only 520 W, at 150 °C 1200 W, at 300 °C 2340 W

Other relevant details include a robust double-door construction for reliable separation of the interior from the laboratory environment, IP 20 protection class in accordance with EN 60529, and high-quality workmanship "Made in Germany" that guarantees durability.

The user-friendly interface allows temperature profiles to be precisely defined, saved and documented - indispensable for QA specifications, validations and the traceability of test results. Ethernet connectivity supports integration into modern laboratory IT infrastructures and remote monitoring.

Special features and safety features

A striking safety feature is the multi-stage electronically controlled monitoring system: in addition to the fault diagnosis system, a temperature selector guard with visual and acoustic alarms ensures maximum process reliability. The system logs all essential parameters - including any malfunctions - without interruption in order to comply with GLP/GMP requirements.

Certifications and standards

The FED 400 is certified in accordance with DIN 58947, which guarantees safe hot air sterilisation (e.g. for laboratory utensils) at 180 °C. The temperature data recorded is based on factory measurements in accordance with DIN 12880, providing users with verifiable quality and compliance with relevant standards. Versatile applications in everyday laboratory work The heating cabinet is used in many scientific and industrial areas:

  • Cultivation of microorganisms
    • Ideal for the growth and analysis of bacterial and fungal cultures under controlled conditions with constant air circulation.
  • Incubation and development processes
    • Perfect for incubating eggs and developing insect larvae, for example in biological control procedures.
  • Cell and tissue cultures
    • Enables exact replication of physiological conditions for cell growth and viability testing in medical and biological research.
  • Material testing and drying
    • Indispensable for thermal stress testing, drying polymer or metal samples, hardness testing and material stress analysis.
  • Sterilisation
    • Suitable for the safe hot air sterilisation of laboratory equipment, glassware, surgical instruments and sample containers in accordance with DIN 58947.
  • Storage and degassing
    • For the safe storage of temperature-sensitive chemicals and targeted degassing of materials prior to further processing.

Relevant substances include water, ethanol, nutrient solutions, agar plates, pharmaceutical preparations, plastic and metal samples, and animal cell lines.

Frequently asked questions (FAQs)

How accurately can the temperature be controlled?

A powerful microprocessor controller enables precise setpoint and actual value adjustment. The forced air circulation ensures stable temperature control and minimal fluctuations, even with changing loads.

What safety precautions are integrated?

The system has an electronic error system with visual and audible alarms, an independent temperature monitor and a real-time clock with documentation function for all critical operating data.

How often does the cabinet need to be cleaned and how is it cleaned?

The high-quality stainless steel interior can be cleaned hygienically and easily. Regular cleaning after each use is recommended, especially for microbiological work. Only use suitable cleaning agents and allow to dry before loading new items.

Can the heating cabinet be expanded with additional accessories?

Yes, various inserts and special stainless steel racks as well as additional sensors and software solutions are available to meet laboratory requirements.

Final assessment

The forced convection heating cabinet combines powerful temperature precision, high safety and flexible application options. It is a first-class solution for demanding laboratory and industrial environments that value reliability, efficient heating processes and standard-compliant results. Thanks to comprehensive documentation options and intelligent control, the device offers remarkable user comfort and maximum process control for numerous laboratory tasks.


Load max.: 51 - 100 kg
Width outside (incubators,...): 1235 mm
Width inside (incubators,...): 1000 mm
Maximum temperature (heat): + 300 °C
Height outside (incubators,...): 1025 mm
Height inside (incubators,...): 800 mm
Interior volume: 301 - 400 l
Cabinet type: heating oven
Depth outside (incubators,...): 765 mm
Depth inside (incubators,...): 500 mm
BINDER Heating chamber FED 400
Exterior dimensions
Width (mm) 1235
Height (incl. feet) (mm) 1025
Depth (mm) 765
Plus door handle, I-panel, connection (mm) 105
Wall clearance, rear (mm) 100
Wall clearance, side (mm) 160
Exhaust duct (outer Ø mm) 52
Steam space volume (l) 498
Number of doors (ea.) 2
Interior dimensions
Width (mm) 1000
Height (mm) 800
Depth (mm) 500
Interior volume (l) 400
Racks (number standard/max.) 2 / 10
Load per rack (kg) 35
Permitted total load (kg) 90
Weight (empty) (kg) 145
Temperature data
Temperature range approx. 5 °C above ambient temperature to (°C) 300
Temperature variation 1)
at 70 °C (± K)
at 150 °C (± K)
at 300 °C (± K)

1
2,5
4,8
Temperature fluctuation at 70 °C (± K) 0,3
Warm-up time 1)
to 70 °C (min)
to 150 °C (min.)
to 250 °C (min)

18
35
60
Recovery time after doors were open for 30 sec. 1)
at 70 °C (min)
at 150 °C (min)
at 300 °C (min)

2
17
21
Ventilation data
Ventilation
at 70 °C (x/h)
at 150 °C (x/h)
at 300 °C (x/h)

17
18
16
Electrical data
IP protection class acc. to EN 60529 IP 20
Voltage (± 10%) 50 / 60 Hz (V) 400, 3 N ~
Nominal power (kW) 3,4
Energy consumption
at 70 °C (W)
at 150 °C (W)
at 300 °C (W)

520
1200
2340

1)to 98% of the set value
All technical data are specified for units with standard equipment at an ambient temperature of 25 °C and a line voltage fluctuation of ±10%. The temperature data is determined in accordance to factory standard following DIN 12880, respecting the recommended wall clearances of 10% of the height, width and depth of the inner chamber. All figures are typical average values for series devices. We reserve the right to alter technical specifications at any time.

Information on product safety
Manufacturer information:
Binder GmbH
Im Mittleren Ösch 5
78532 Tuttlingen, Deutschland
[email protected]
Responsible person:
Mr. Schuldt
0049 30 403 667 940
[email protected]

Accessories

Data Logger Kit T 350 Details
Price on application
Data Logger Software Details
Price on application
Anti-slip rubber pads Details
Price on application

Related products