BINDER Growth chamber KBW 240 - ProfiLab24 GmbH
99
100
24
4
stars -
Professional service
Customer
Young team with a lot of ambition and quick answers to all questions. We needed a complete laboratory equipment for our new location. The team of Profiab24 has arranged everything.
BINDER Growth chamber KBW 240
Item number: S-144
EAN: 4064343073790
Manufacturer:
Binder
15.391,00 €
Manufacturers suggested retail price:
15.391,00 €
Excluding 19% VAT. ,
plus
(Sperrgut)
(including 19% VAT. 18.315,28 €)
BINDER Growth chamber KBW 240 . ProfiLab24.com laboratory supplies and laboratory equipment with top advice and 24H service
BINDER Growth chamber KBW 240
Growth chambers with light
The BINDER climate chamber with illumination of the KBW series achieves homogeneous light distribution with its natural illumination. That allows this growth chamber to create constant lighting and temperature conditions.
BENEFITS
- Patented lighting system ensures homogeneous light distribution
- Flexible positioning of illumination cassettes, three different light spectra, individually selectable
- Integrated weekly program in real-time
MAIN FEATURES
- Temperature range: 0 °C to 70 °C
- Temperature range with light: 5 °C to 60 °C
- 2 positionable illumination cassettes, each with 5 fluorescent tubes
- APT.line preheating chamber technology
- Adjustable fan speed
- Intuitive touchscreen controller with time-segment and real-time programming with internal data recording
- 2 stainless steel racks
- Access port with silicone plug, 30 mm, left
- Class 3.1 independent temperature safety device (DIN 12880) with visual and audible temperature alarm
- Computer interface: Ethernet
- Door heating
- Tight-sealing inner door made of safety glass (ESG) with special TIMELESS coating
Load max.:
|
51 - 100 kg
|
Width outside (incubators,...):
|
925 mm
|
Width inside (incubators,...):
|
650 mm
|
Maximum temperature (heat):
|
+ 70 °C
|
Height outside (incubators,...):
|
1465 mm
|
Height inside (incubators,...):
|
785 mm
|
Interior volume:
|
201 - 300 l
|
Cabinet type:
|
growth chamber
|
Depth outside (incubators,...):
|
800 mm
|
Depth inside (incubators,...):
|
485 mm
|
Lowest temperature (cooling):
|
0 °C
|
Product weight: |
195,00 Kg |
Dimensions: |
× × cm |
BINDER Growth chamber |
KBW 240-230V1) |
Performance Data Temperature |
|
Temperature range without illumination cassettes [°C] |
0...70 |
Temperature range with 100% illumination [°C] |
5...60 |
Temperature variation with 100% illumination [± K] |
0.5 |
Temperature variation without illumination cassettes [± K] |
0.5 |
Temperature fluctuation without illumination cassettes [± K] |
0.1 |
Temperature fluctuation with 100% illumination [± K] |
0.2 |
Lightdata per Illumination Cassettes2) |
|
Daylight tubes [W/m2] |
24 |
Daylight tubes [lx] |
9000 |
Fluora growth lamps [W/m2] |
23 |
Fluora growth lamps [lx] |
7500 |
Arabidopsis lamps [W/m2] |
32 |
Arabidopsis lamps [lx] |
11000 |
Electrical data |
|
Rated Voltage [V] |
200...240 |
Power frequency [Hz] |
50 |
Nominal power [kW] |
1.4 |
Unit fuse [A] |
16 |
Phase (Nominal voltage) [ph] |
1 |
Outer dimensions not incl. fittings and connections |
|
Width net [mm] |
925 |
Height net [mm] |
1465 |
Depth net [mm] |
800 |
Wall clearance back [mm] |
100 |
Wall clearance sidewise [mm] |
100 |
Doors |
|
Inner doors |
1 |
Unit doors |
1 |
Internal Dimensions |
|
Width [mm] |
650 |
Height [mm] |
785 |
Depth [mm] |
485 |
Measures |
|
Interior volume [L] |
247 |
Net weight of the unit (empty) [kg] |
195 |
permitted load [kg] |
100 |
Load per rack [kg] |
30 |
Environment-specific data |
|
Energy consumption at 37 °C and with illumination [Wh/h] |
450 |
Sound-pressure level [dB(A)] |
53 |
Fixtures |
|
Number of shelves (std./max.) |
2/17 |
Number of illumination cassettes (std./max.) |
2/2 |
1) All technical data is specified for unloaded units with standard equipment at an ambient temperature of +22 °C ±3 °C and a power supply voltage fluctuation of ±10 %. The temperature data is determined in accordance to BINDER factory standard following DIN 12880, observing the recommended wall clearances of 10 % of the height, width, and depth of the inner chamber. Technical data refers to 100 % fan speed. All indications are average values, typical for units produced in series. We reserve the right to change technical specifications at any time.
2) Average value, measured at 25 °C with a spherical sensor (±10 %) by 12 cm below the light cassette. The values given in W/m2 refer to global radiation.