BINDER B 28 incubator with temperature limiter
The BINDER Incubator B 28 with temperature limiter is a highly precise and reliable laboratory device that has been specially designed for demanding applications in biological, microbiological, and medical research. Thanks to its precise temperature control, high uniformity of temperature distribution, and modern control functions, this model is ideal for applications where stable and reproducible conditions are essential. Thanks to its robust construction, user-friendly interface and integrated safety functions, the B 28 incubator is often the preferred choice in laboratories when it comes to cell or microorganism cultures as well as development and incubation processes under controlled conditions.
Reliability and precision for optimal laboratory conditions
The BINDER B 28 incubator impresses with its combination of state-of-the-art temperature control, versatile equipment, and convenient operation. With an interior volume of 28 litres and flexible options for inserting up to four shelves, the incubator offers sufficient space for a wide variety of vessels and culture systems. The temperature can be precisely controlled in the range from 5 °C above room temperature to 70 °C, with a temperature deviation of only ±1 K at 37 °C - a critical factor for consistent test results.
Technical highlights at a glance
- Temperature range: 5 °C above room temperature to 70 °C (30-70 °C adjustable)
- Interior volume: 28 litres
- Temperature accuracy: Temporal deviation at 37 °C ±1 K
- Max. permissible total load: 25 kg, up to 10 kg per shelf
- Dimensions (interior): 400 x 280 x 250 mm (W x H x D)
- Dimensions (external): 580 x 405 x 425 mm (W x H x D)
- Nominal voltage: 230 V, nominal power: 0.25 kW
- Protection class: IP 20 in accordance with EN 50529
In addition, the unit is equipped with a BINDER controller that offers intuitive menu navigation. The controller enables the simultaneous display of all relevant parameters, a real-time clock with electronic line recorder, and comprehensive logging of process data. Safety features such as a visual and audible temperature alarm, drift-free CO2 infrared absorption measuring system, and an automatic fault diagnosis system make the incubator particularly reliable.
Special features include consistent temperature homogeneity thanks to the BINDER-typical VENTAIR air jacket system (depending on model) and the tight-fitting inner door, which prevents contamination. Optionally, standard-compliant hot air sterilisation in accordance with DIN 58947 can be carried out.
Compliance with important standards and certifications
The BINDER B 28 incubator complies with the requirements of DIN 12880 and is calibrated according to factory standards, which guarantees compliance with strict quality standards in daily laboratory operations. Electrical safety is ensured by protection class IP 20 in accordance with EN 50529. With the optional measuring system, the CO? concentration can also be controlled without drift, which is particularly important for sensitive cell cultures.
Typical areas of application and specific uses
Thanks to its versatile and sophisticated technology, this device is suitable for a wide range of applications in research and development. In professional laboratory environments in particular, users benefit from the precise and stable climate conditions for the following applications:
-
Cultivation of bacteria and fungi: Production and observation of microbiological cultures for diagnostics, food testing or biotechnological processes.
-
Cell growth studies: Establishment of cell cultures (e.g. mammalian cells) for toxicological testing or pharmaceutical drug research with precise control of environmental conditions, including CO2 regulation.
-
Breeding processes in embryology: Ensuring optimal climate control for embryo development in research projects.
-
Long-term incubations for molecular biological investigations: Stable temperature for hybridisations or enzyme activity studies, e.g. in the field of PCR/qPCR.
-
Stability testing under reproducible conditions: Testing and quality control of sensitive products, e.g. cosmetic or pharmaceutical samples.
Typical substances used in incubators are culture media for microorganisms (LB, Müller-Hinton, Sabouraud agar), pH buffer solutions, and cell culture media (DMEM, RPMI) - optimal conditions are ensured by the precise control of all relevant parameters. Frequently asked questions (FAQs) How accurately can the temperature in the incubator be set?
Thanks to the precise temperature controller and modern BINDER controller, the temperature can be set and maintained at exact increments in the range from 30 to 70 °C; temperature fluctuations are actively compensated.
What safety features does the incubator have?
It has visual and audible alarms, an automatic fault diagnosis system, and a potential-free changeover contact for external monitoring. The lockable inner door provides additional contamination control.
Is the unit suitable for CO? incubation and sensitive cell cultures?
Yes, an optional drift-free CO? infrared absorption measurement system is integrated, which allows the CO? concentration to be constantly monitored and regulated - ideal for demanding cell culture work.
Which standards does the device comply with?
It complies with DIN 12880 for temperature accuracy and electrical safety requirements (EN 50529).
How many sample vessels or culture dishes can be incubated at the same time?
The interior can accommodate up to four insert racks, each with a maximum load of 10 kg. The number of vessels depends on their size.
Which media can be used in the incubator?
Both standard culture media for germs (e.g. LB broth, blood agar) and cell culture media (DMEM, RPMI) are compatible.
How are data and settings documented?
All important process data is recorded in a traceable manner thanks to electronic storage and graphical display on the controller, as well as an optional integrated electronic line recorder.
Conclusion
The BINDER B 28 incubator with temperature limiter offers laboratory professionals maximum precision, versatility, and user safety for the cultivation of a wide variety of organisms and cell types. With exemplary temperature stability, comprehensive safety features, and standard-compliant design, this model is the optimal choice for high-quality research results and reliable routine tasks in the modern laboratory.