BINDER KBW 400 (E5.1) Climate chamber - ProfiLab24 GmbH
99
100
24
4
stars -
Professional service
Customer
Young team with a lot of ambition and quick answers to all questions. We needed a complete laboratory equipment for our new location. The team of Profiab24 has arranged everything.
BINDER KBW 400 (E5.1) Climate chamber
Item number: BIND_6049!
EAN: 4064343304092
Manufacturer:
Binder
Now only
14.124,22 €
Manufacturers suggested retail price:
14.867,60 €
Excluding 19% VAT. ,
plus
(Sperrgut)
(including 19% VAT. 16.807,82 €)
BINDER KBW 400 (E5.1) Climate chamber. Order online at ProfiLab24 .com with top advice and 24/7 service. Fast delivery. Secure payment.
BINDER KBW 400 (E5.1) Climate chamber with illumination
The BINDER climate chamber with illumination of the KBW series achieves homogeneous light distribution with its natural illumination. That allows this climate chamber to create constant lighting and temperature conditions.
- Electronically controlled APT.lineTM preheating chamber assuring temperature accuracy and reproducible results
- Temperature range 0 °C to 70 °C (without illumination)
- Temperature range 5 °C to 60 °C (with illumination)
- 3 variable positioned illumination cassettes with 5 daylight illumination tubes, each, in steps switchable
- The patented illumination system assures an unique homogeneous light distribution
- MP controller with 2 programs with 10 sections each, alternatively switchable to 1 program with 20 sections
- Integrated week program timer with real time function
- Digital temperature setting with an accuracy of a tenth of a degree
- Adjustable ramp functions via program editor
- Adjustable fan speed
- Elapsed time indicator
- Access port Ø 30 mm, left side
- Inner glass door
- Independent adjustable temperature safety device class 3.1, providing full protection against chamber over-temperature, with visual and audible temperature alarm
- RS 422 interface for communication software APT-COMTM DataControlSystem
- Adjustable intervals for printer
- 3 stainless steel racks
- BINDER test confirmation
Load max.:
|
101 - 150 kg
|
Width outside (incubators,...):
|
930 mm
|
Width inside (incubators,...):
|
650 mm
|
Maximum temperature (heat):
|
+ 70 °C
|
Height outside (incubators,...):
|
1945 mm
|
Height inside (incubators,...):
|
1270 mm
|
Interior volume:
|
301 - 400 l
|
Cabinet type:
|
climate chamber
|
Depth outside (incubators,...):
|
880 mm
|
Depth inside (incubators,...):
|
485 mm
|
Lowest temperature (cooling):
|
0 °C
|
BINDER Climate chamber |
KBW 400 (E5.1) |
Exterior dimensions |
|
Width (mm) |
930 |
Height (incl. feet) (mm) |
1945 |
Depth (incl. door handle, I-triangle, connection 80 mm) (mm) |
880 |
Wall clearance, rear (mm) |
100 |
Wall clearance, side (mm) |
100 |
Steam space volume (l) |
564 |
Number of doors (ea.) |
1 |
Number of inner glass door(s) (ea.) |
1 |
Interior dimensions |
|
Width (mm) |
650 |
Height (mm) |
1270 |
Depth (mm) |
485 |
Interior volume (l) |
400 |
Racks (number standard/max.) |
3 / 12 |
Load per rack (kg) |
30 |
Permitted total load (kg) |
120 |
Weight (empty) (kg) |
267 |
Variable position illumination cassettes |
3 |
Temperature data (without illumination) |
|
Temperature range (°C) |
0 - 70 |
Temperature variation (± K) |
0,5 |
Temperature fluctuation (± K) |
0,1 |
Max. heat compensation up to 40 °C (W) |
600 |
Temperature data (with 100 % illumination) |
|
Temperature range (°C) |
5 - 60 |
Temperature variation (± K) |
1,5 |
Temperature fluctuation (± K) |
0,1 |
Max. heat compensation up to 40 °C (W) |
450 |
Illumination data (per illumination cassette) |
|
Daylight tubes (Lux) / (W/m2) |
9.000 / 24 |
Fluora® growth lamps (Lux) / (W/m2) |
7.500 / 23 |
Arabidopsis tubes (Lux) / (W/m2) |
11.000 / 32 |
Electrical data |
|
IP protection class acc. to EN 60529 |
IP 20 |
Voltage (± 10 %) 50 / 60 Hz (V) |
200 - 240, 1 N ~ |
Nominal power (kW) |
1,6 |
Energy consumption 1) without illumination at 0 °C (W) with illumination at 4 °C (W) with illumination at 25 °C (W) with illumination at 37 °C (W) |
405 675 660 705 |
Noise level (dB (A)) |
53 |
1) These values can be used for dimensioning air condition systems.
All technical data are specified for units with standard equipment at an ambient temperature of 25 °C and a line voltage fluctuation of ±10%. The temperature data is determined in accordance to factory standard following DIN 12880, respecting the recommended wall clearances of 10% of the height, width and depth of the inner chamber. All figures are typical average values for series devices. We reserve the right to alter technical specifications at any time.