BINDER Material test chamber FP 115 - ProfiLab24 GmbH
99
100
24
4
stars -
Professional service
Customer
Young team with a lot of ambition and quick answers to all questions. We needed a complete laboratory equipment for our new location. The team of Profiab24 has arranged everything.
BINDER Material test chamber FP 115
Item number: BIND_6052!
EAN: 4064343302944
Manufacturer:
Binder
starting from
3.801,90 €
Manufacturers suggested retail price:
4.002,00 €
Excluding 19% VAT. ,
plus
(Sperrgut)
(including 19% VAT. 4.524,26 €)
BINDER Material test chamber FP 115 at ProfiLab24 dealer for laboratory equipment. Made in Germany with top advice and 24H service.
- Power supply
-
There are variations of this item. Please select the variation you wish.
BINDER Material test chamber FP 115 with mechanical convection
A BINDER material test chamber with mechanical convection of the FP series provides reliably short drying times and particularly fast heating - even for chambers under full loads.
- Electronically controlled APT.lineTM preheating chamber assuring temperature accuracy and reproducible results
- Temperature range from 5 °C above ambient temperature to 300 °C
- MP controller with 2 programs with 10 sections each, or alternatively 1 program with 20 sections
- The time of an individual program step can be set to max. 99.59 hours or 999.59 hours. This adjustment applies to all program sections.
- Integrated weekly program timer with real-time function
- Adjustable ramp function via program editor
- Digital temperature setting with an accuracy of one degree
- Adjustable fan speed
- Adjustable ventilation by means of front ventilation flap slide and rear exhaust Ø 50 mm
- Elapsed time indicator
- Independent adjustable temperature safety device class 2 (DIN 12880), with visual temperature alarm
- RS 422 interface for use with APT-COMTM DataControlSystem communication software or switch over to printer output with RS 232 / RS 422 interface converter
- Units up to 115 liters are stackable
- 2 chrome-plated racks included
- BINDER test confirmation
Load max.:
|
11 - 50 kg
|
Width outside (incubators,...):
|
835 mm
|
Width inside (incubators,...):
|
600 mm
|
Maximum temperature (heat):
|
+ 300 °C
|
Height outside (incubators,...):
|
705 mm
|
Height inside (incubators,...):
|
480 mm
|
Interior volume:
|
101 - 200 l
|
Cabinet type:
|
material test chamber
|
Depth outside (incubators,...):
|
645 mm
|
Depth inside (incubators,...):
|
410 mm
|
BINDER Material test chamber |
FP 115 |
Exterior dimensions |
|
Width (mm) |
835 |
Height (incl. feet) (mm) |
705 |
Depth (mm) |
645 |
Plus door handle and connection (mm) |
105 |
Wall clearance, rear (mm) |
100 |
Wall clearance, side (mm) |
160 |
Exhaust duct (outer Ø mm) |
52 |
Steam space volume (l) |
158 |
Number of doors (ea.) |
1 |
Interior dimensions |
|
Width (mm) |
600 |
Height (mm) |
480 |
Depth (mm) |
410 |
Interior volume (l) |
115 |
Racks (number standard/max.) |
2 / 6 |
Load per rack (kg) |
20 |
Permitted total load (kg) |
50 |
Weight (empty) (kg) |
62 |
Temperature data |
|
Temperature range approx. 5 °C above ambient temperature to(°C) |
300 |
Temperature variation at 70 °C (± K) at 150 °C (± K) at 300 °C (± K) |
0,7 1,8 3,9 |
Temperature fluctuation (± K) |
0,3 |
Warm-up time to 70 °C (min.) to 150 °C (min.) to 250 °C (min.) |
7 30 49 |
Recovery time after doors were open for 30 sec. 1) at 70 °C (min.) at 150 °C (min.) at 300 °C (min.) |
2 8 15 |
Ventilation data |
|
Ventilation at 70 °C (x/h) at 150 °C (x/h) at 300 °C (x/h) |
29 32 26 |
Electrical data |
|
IP protection class acc. to EN 60529 |
IP 20 |
Voltage (± 10%) 50 / 60 Hz (V) |
230, 1 N ~ |
Nominal power (kW) |
1,6 |
Energy consumption at 70 °C (W) at 150 °C (W) at 300 °C (W) |
230 544 1100 |
1) To 98% of the set value
All technical data are specified for units with standard equipment at an ambient temperature of 25 °C and a line voltage fluctuation of ±10%. The temperature data is determined in accordance to factory standard following DIN 12880, respecting the recommended wall clearances of 10% of the height, width and depth of the inner chamber. All figures are typical average values for series devices. We reserve the right to alter technical specifications at any time.