BINDER Material test chamber FP 115

Item number: BIND_6052!

EAN: 4064343302944

Category: BINDER

Manufacturer: Binder

starting from 3.801,90 €

Manufacturer’s suggested retail price: 4.002,00 €

Excluding 19% VAT. , plus shipping (Sperrgut)

(including 19% VAT. 4.524,26 €)
Power supply

There are variations of this item. Please select the variation you wish.


BINDER Material test chamber FP 115 with mechanical convection
A BINDER material test chamber with mechanical convection of the FP series provides reliably short drying times and particularly fast heating - even for chambers under full loads.

  • Electronically controlled APT.lineTM preheating chamber assuring temperature accuracy and reproducible results
  • Temperature range from 5 °C above ambient temperature to 300 °C
  • MP controller with 2 programs with 10 sections each, or alternatively 1 program with 20 sections
  • The time of an individual program step can be set to max. 99.59 hours or 999.59 hours. This adjustment applies to all program sections.
    • Integrated weekly program timer with real-time function
    • Adjustable ramp function via program editor
  • Digital temperature setting with an accuracy of one degree
  • Adjustable fan speed
  • Adjustable ventilation by means of front ventilation flap slide and rear exhaust Ø 50 mm
  • Elapsed time indicator
  • Independent adjustable temperature safety device class 2 (DIN 12880), with visual temperature alarm
  • RS 422 interface for use with APT-COMTM DataControlSystem communication software or switch over to printer output with RS 232 / RS 422 interface converter
  • Units up to 115 liters are stackable
  • 2 chrome-plated racks included
  • BINDER test confirmation

Load max.: 11 - 50 kg
Width outside (incubators,...): 835 mm
Width inside (incubators,...): 600 mm
Maximum temperature (heat): + 300 °C
Height outside (incubators,...): 705 mm
Height inside (incubators,...): 480 mm
Interior volume: 101 - 200 l
Cabinet type: material test chamber
Depth outside (incubators,...): 645 mm
Depth inside (incubators,...): 410 mm
BINDER Material test chamber FP 115
Exterior dimensions
Width (mm) 835
Height (incl. feet) (mm) 705
Depth (mm) 645
Plus door handle and connection (mm) 105
Wall clearance, rear (mm) 100
Wall clearance, side (mm) 160
Exhaust duct (outer Ø mm) 52
Steam space volume (l) 158
Number of doors (ea.) 1
Interior dimensions
Width (mm) 600
Height (mm) 480
Depth (mm) 410
Interior volume (l) 115
Racks (number standard/max.) 2 / 6
Load per rack (kg) 20
Permitted total load (kg) 50
Weight (empty) (kg) 62
Temperature data
Temperature range approx. 5 °C above ambient temperature to(°C) 300
Temperature variation
at 70 °C (± K)
at 150 °C (± K)
at 300 °C (± K)

0,7
1,8
3,9
Temperature fluctuation (± K) 0,3
Warm-up time
to 70 °C (min.)
to 150 °C (min.)
to 250 °C (min.)

7
30
49
Recovery time after doors were open for 30 sec. 1)
at 70 °C (min.)
at 150 °C (min.)
at 300 °C (min.)

2
8
15
Ventilation data
Ventilation
at 70 °C (x/h)
at 150 °C (x/h)
at 300 °C (x/h)

29
32
26
Electrical data
IP protection class acc. to EN 60529 IP 20
Voltage (± 10%) 50 / 60 Hz (V) 230, 1 N ~
Nominal power (kW) 1,6
Energy consumption
at 70 °C (W)
at 150 °C (W)
at 300 °C (W)

230
544
1100

1) To 98% of the set value

All technical data are specified for units with standard equipment at an ambient temperature of 25 °C and a line voltage fluctuation of ±10%. The temperature data is determined in accordance to factory standard following DIN 12880, respecting the recommended wall clearances of 10% of the height, width and depth of the inner chamber. All figures are typical average values for series devices. We reserve the right to alter technical specifications at any time.


Accessories

BINDER Shelf for 115 Details
Price on application
Data Logger Kit T 350 Details
Price on application
Data Logger Software Details
Price on application
Anti-slip rubber pads Details
Price on application

Related products