BINDER Material test chamber FP 240 - ProfiLab24 GmbH
99
100
24
4
stars -
Professional service
Customer
Young team with a lot of ambition and quick answers to all questions. We needed a complete laboratory equipment for our new location. The team of Profiab24 has arranged everything.
BINDER Material test chamber FP 240
Item number: BIND_6053>
EAN: 4064343302913
Manufacturer:
Binder
Now only
5.251,60 €
Manufacturers suggested retail price:
5.528,00 €
Excluding 19% VAT. ,
plus
(Sperrgut)
(including 19% VAT. 6.249,40 €)
BINDER Material test chamber FP 240. Order at ProfiLab24.com Online Catalog. Fast delivery. Secure payment and 24/7 service.
- Power supply
-
There are variations of this item. Please select the variation you wish.
BINDER Material test chamber FP 240 with mechanical convection
A BINDER material test chamber with mechanical convection of the FP series provides reliably short drying times and particularly fast heating - even for chambers under full loads.
- Electronically controlled APT.lineTM preheating chamber assuring temperature accuracy and reproducible results
- Temperature range from 5 °C above ambient temperature to 300 °C
- MP controller with 2 programs with 10 sections each, or alternatively 1 program with 20 sections
- The time of an individual program step can be set to max. 99.59 hours or 999.59 hours. This adjustment applies to all program sections
- Integrated weekly program timer with real-time function
- Adjustable ramp function via program editor
- Digital temperature setting with an accuracy of one degree
- Adjustable fan speed
- Adjustable ventilation by means of front ventilation flap slide and rear exhaust Ø 50 mm
- Elapsed time indicator
- Independent adjustable temperature safety device class 2 (DIN 12880), with visual temperature alarm
- RS 422 interface for use with APT-COMTM DataControlSystem communication software or switch over to printer output with RS 232 / RS 422 interface converter
- Units up to 115 liters are stackable
- 2 chrome-plated racks included
- BINDER test confirmation
Load max.:
|
51 - 100 kg
|
Width outside (incubators,...):
|
1235 mm
|
Width inside (incubators,...):
|
1000 mm
|
Maximum temperature (heat):
|
+ 300 °C
|
Height outside (incubators,...):
|
1025 mm
|
Height inside (incubators,...):
|
800 mm
|
Interior volume:
|
201 - 300 l
|
Cabinet type:
|
material test chamber
|
Depth outside (incubators,...):
|
765 mm
|
Depth inside (incubators,...):
|
510 mm
|
BINDER Material test chamber |
FP 240 |
Exterior dimensions |
|
Width (mm) |
1035 |
Height (inkl. Füße) (mm) |
825 |
Depth (mm) |
745 |
Plus door handle and connection (mm) |
105 |
Wall clearance, rear (mm) |
100 |
Wall clearance, side (mm) |
160 |
Exhaust duct (Außen-Ø mm) |
52 |
Steam space volume (l) |
308 |
Number of doors (ea.) |
2 |
Interior dimensions |
|
Width (mm) |
800 |
Height (mm) |
600 |
Depth (mm) |
510 |
Interior volume (l) |
240 |
Racks (number standard/max.) |
2 / 7 |
Load per rack (kg) |
30 |
Permitted total load (kg) |
70 |
Weight (empty) (kg) |
98 |
Temperature data |
|
Temperature range approx. 5 °C above ambient temperature to(°C) |
300 |
Temperature variation at 70 °C (± K) at 150 °C (± K) at 300 °C (± K) |
0,8 2 4,3 |
Temperature fluctuation (± K) |
0,3 |
Warm-up time to 70 °C (min.) to 150 °C (min.) to 250 °C (min.) |
12 27 50 |
Recovery time after doors were open for 30 sec. 1) at 70 °C (min.) at 150 °C (min.) at 300 °C (min.) |
2 10 16 |
Ventilation data |
|
Ventilation at 70 °C (x/h) at 150 °C (x/h) at 300 °C (x/h) |
19 20 18 |
Electrical data |
|
IP protection class acc. to EN 60529 |
IP 20 |
Voltage (± 10%) 50 / 60 Hz (V) |
230, 1 N ~ |
Nominal power (kW) |
2,7 |
Energy consumption at 70 °C (W) at 150 °C (W) at 300 °C (W) |
370 850 1400 |
1) To 98% of the set value
All technical data are specified for units with standard equipment at an ambient temperature of 25 °C and a line voltage fluctuation of ±10%. The temperature data is determined in accordance to factory standard following DIN 12880, respecting the recommended wall clearances of 10% of the height, width and depth of the inner chamber. All figures are typical average values for series devices. We reserve the right to alter technical specifications at any time.