BINDER Material test chamber FP 400 - ProfiLab24 GmbH
99
100
24
4
stars -
Professional service
Customer
Young team with a lot of ambition and quick answers to all questions. We needed a complete laboratory equipment for our new location. The team of Profiab24 has arranged everything.
BINDER Material test chamber FP 400
Item number: BIND_6054!
EAN: 4064343302869
Manufacturer:
Binder
Now only
6.776,35 €
Manufacturers suggested retail price:
7.133,00 €
Excluding 19% VAT. ,
plus
(Sperrgut)
(including 19% VAT. 8.063,86 €)
BINDER Material test chamber FP 400 at ProfiLab24 dealer for laboratory equipment. Made in Germany with top advice and 24H service.
- Power supply
-
There are variations of this item. Please select the variation you wish.
BINDER Material test chamber FP 400 with mechanical convection
A BINDER material test chamber with mechanical convection of the FP series provides reliably short drying times and particularly fast heating - even for chambers under full loads.
- Electronically controlled APT.lineTM preheating chamber assuring temperature accuracy and reproducible results
- Temperature range from 5 °C above ambient temperature to 300 °C
- MP controller with 2 programs with 10 sections each, or alternatively 1 program with 20 sections
- The time of an individual program step can be set to max. 99.59 hours or 999.59 hours. This adjustment applies to all program sections
- Integrated weekly program timer with real-time function
- Adjustable ramp function via program editor
- Digital temperature setting with an accuracy of one degree
- Adjustable fan speed
- Adjustable ventilation by means of front ventilation flap slide and rear exhaust Ø 50 mm
- Elapsed time indicator
- Independent adjustable temperature safety device class 2 (DIN 12880), with visual temperature alarm
- RS 422 interface for use with APT-COMTM DataControlSystem communication software or switch over to printer output with RS 232 / RS 422 interface converter
- Units up to 115 liters are stackable
- 2 chrome-plated racks included
- BINDER test confirmation
Load max.:
|
51 - 100 kg
|
Width outside (incubators,...):
|
1235 mm
|
Width inside (incubators,...):
|
1000 mm
|
Maximum temperature (heat):
|
+ 300 °C
|
Height outside (incubators,...):
|
1025 mm
|
Height inside (incubators,...):
|
800 mm
|
Interior volume:
|
301 - 400 l
|
Cabinet type:
|
material test chamber
|
Depth outside (incubators,...):
|
765 mm
|
Depth inside (incubators,...):
|
510 mm
|
BINDER Material test chamber |
FP 400 |
Exterior dimensions |
|
Width (mm) |
1235 |
Height (incl. feet) (mm) |
1025 |
Depth (mm) |
765 |
Plus door handle and connection (mm) |
105 |
Wall clearance, rear (mm) |
100 |
Wall clearance, side (mm) |
160 |
Exhaust duct (outer Ø mm) |
52 |
Steam space volume (l) |
498 |
Number of doors (ea.) |
2 |
Interior dimensions |
|
Width (mm) |
1000 |
Height (mm) |
800 |
Depth (mm) |
510 |
Interior volume (l) |
400 |
Racks (number standard/max.) |
2 / 10 |
Load per rack (kg) |
35 |
Permitted total load (kg) |
90 |
Weight (empty) (kg) |
145 |
Temperature data |
|
Temperature range approx. 5 °C above ambient temperature to(°C) |
300 |
Temperature variation at 70 °C (± K) at 150 °C (± K) at 300 °C (± K) |
1 2,5 4,8 |
Temperature fluctuation (± K) |
0,3 |
Warm-up time to 70 °C (min.) to 150 °C (min.) to 250 °C (min.) |
18 35 60 |
Recovery time after doors were open for 30 sec. 1) at 70 °C (min.) at 150 °C (min.) at 300 °C (min.) |
2 17 21 |
Ventilation data |
|
Ventilation at 70 °C (x/h) at 150 °C (x/h) at 300 °C (x/h) |
17 18 16 |
Electrical data |
|
IP protection class acc. to EN 60529 |
IP 20 |
Voltage (± 10%) 50 / 60 Hz (V) |
400, 3 N ~ |
Nominal power (kW) |
3,4 |
Energy consumption at 70 °C (W) at 150 °C (W) at 300 °C (W) |
520 1200 2340 |
1) To 98% of the set value
All technical data are specified for units with standard equipment at an ambient temperature of 25 °C and a line voltage fluctuation of ±10%. The temperature data is determined in accordance to factory standard following DIN 12880, respecting the recommended wall clearances of 10% of the height, width and depth of the inner chamber. All figures are typical average values for series devices. We reserve the right to alter technical specifications at any time.