RUMED explosion-proof cold/heat cabinet T 1640 - ProfiLab24 GmbH
99
100
24
4
stars -
Professional service
Customer
Young team with a lot of ambition and quick answers to all questions. We needed a complete laboratory equipment for our new location. The team of Profiab24 has arranged everything.
RUMED explosion-proof cold/heat cabinet T 1640 in Incubators, Drying Cabinets
Item number: RUMED_34009E
EAN: 4064343052788
Manufacturer:
RUMED
RUMED explosion-proof cold/heat cabinet T 1640. Order online at ProfiLab24 .com with top advice and 24/7 service. Fast delivery. Secure payment.
RUMED explosion-proof cold/heat cabinet T 1640Explosion protection inside
The RUMED Safety T-Line offers a variable program of cold/heat and environmental test cabinets with explosion-proof test chambers for zone 1. Choose from 5 sizes and a multitude of options.
The units of the Safety T-Line are suitable for safe storage of explosive materials, such as aerosols, or for tests with adhesives or paint - even if the storage tests might occasionally or temporary cause an explosive atmosphere. Development of a permanent or long-term explosive atmosphere must be avoided by means of the option Technical Ventilation. The units are suitable for storage of material of the temperature classes T1, T2 and T3 of explosion group IIA, IIB and IIC. Each individual RUMED unit of the Safety T-Line is subject to an ATEX verification and receives an ATEX approval for zone 1.
Optionally available with extension of the temperature range to -20 °C/+80 °C, humidification and dehumidification and further options. Configure your test equipment, which is the most suitable for your requirements.
General view of the most important advantages:
- Test room Ex II 2G EEx IIC T3
- 5 Test room sizes: 320 l to 1.640 l
- Test room and external housing of solvent-resistant stainless steel
- Recirculating air fan for good temperature distribution in space
- Intuitive handling by means of the Control2015 touch
- Temperature ranges from -20 °C to +80 °C
- Humidification and dehumidification possible
- Possibility of calibration and validation
- Robust and extremely durable
Width outside (incubators,...):
|
1520 mm
|
Width inside (incubators,...):
|
610 mm
|
Maximum temperature (heat):
|
+ 35 °C
|
Height outside (incubators,...):
|
2105 mm
|
Height inside (incubators,...):
|
1500 mm
|
Interior volume:
|
1501 - 2000 l
|
Cabinet type:
|
constant climate chamberclimate chambertemperature conditioning cabinetdynamic climate chamber
|
Depth outside (incubators,...):
|
1250 mm
|
Depth inside (incubators,...):
|
935 mm
|
Lowest temperature (cooling):
|
0 °C
|
Dimensions: |
× × cm |
RUMED expl.-proof cold/heat cabinet Safety T-Line |
T 320 |
T 500 |
T 820 |
T 1000 |
T 1640 |
Test room explosion-proof Ex II 2 G EEx IIC T3 |
|
|
|
|
|
|
Volume (l) |
320 |
500 |
820 |
1000 |
1650 |
Minimum temperature ( °C) |
0 |
0 |
0 |
0 |
0 |
Maximum temperature ( °C) |
+35 |
+35 |
+35 |
+35 |
+35 |
Temperature deviation in time ( °C) |
±0,5 |
±0,5 |
±0,5 |
±0,5 |
±0,5 |
Height (mm) |
990 |
1500 |
1500 |
1500 |
1500 |
Width (mm) |
610 |
610 |
610 |
2x 610 |
2x 610 |
Depth (mm) |
585 |
585 |
935 |
585 |
935 |
Number of shelves (standard delivery scope) |
3 |
4 |
4 |
8 |
8 |
Maximum load per shelf (kg) |
25 |
25 |
25 |
25 |
25 |
Unit |
|
|
|
|
|
Height (mm) |
1600 |
2105 |
2105 |
2105 |
2105 |
Width (mm) |
760 |
760 |
760 |
1520 |
1520 |
Depth (mm) |
900 |
900 |
1250 |
900 |
1250 |
Electric connection (V/Hz) |
230/50 |
230/50 |
230/50 |
230/50 |
230/50 |
Options |
|
|
|
|
|
Additional shelf |
* |
* |
* |
* |
* |
Additional shelf, reinforced (maximum load per shelf 50 kg) |
* |
* |
* |
* |
* |
Glazed panel door, no pane heating |
* |
* |
* |
* |
* |
Extension of temperature range down to -20 °C |
* |
* |
* |
* |
* |
Extension of temperature range up to +80 °C 1)
|
|
* |
* |
* |
* |
Speed rate in temperature change 1 °C/min (0 °C to +35 °C) |
* |
* |
* |
* |
* |
Speed rate in temperature change 1 °C/min (-20 °C to +80 °C) |
* |
* |
* |
* |
* |
Ultrasonic humidification + dehumidification 2)
|
* |
* |
* |
* |
* |
* available at extra charge
1) Electric connection is then 400 V/230 V/50 Hz, unit depth is then +225 mm
2) Unit depth is then +160 mm, removable for transportation