Dräger PAC 7000

Item number: DRAEG_37015>

Category:

Dräger

Manufacturer: Dräger

Price on application
Variations

There are variations of this item. Please select the variation you wish.


Dräger PAC 7000

Warns against hazardous gas concentrations
Every working day places the highest demands on gas monitoring. The device reliably warns against hazardous concentrations of carbon monoxide, hydrogen sulphide (including a Low Concentration option), oxygen, carbon dioxide, sulphur dioxide, chlorine, hydrogen cyanide, ammonia, nitrogen dioxide, nitrogen monoxide, phosphine and organic vapours.

Simple calibration and configuration
The bump test mode and sensitivity calibration can be selected via a password-protected menu. The fresh air calibration can be optimally protected using a password. The device is equipped with an infrared interface and can be connected to a PC via a communication cradle in order to activate the desired functions or download stored data.

Innovative miniature sensors
The innovative Dräger XXS sensors react quickly and produce reliable measurement results. Very short diffusion paths inside the device, as well as the sensors' rapid electrochemical reactions, ensure that any gas-related dangers are displayed as soon as they occur. For maximum safety, the sensor is positioned inside the housing such as to allow gas to reach it from above and from the front. This guarantees flawless measurement, even when the gas entry has been accidentally obstructed.

5-year guarantee option
Dräger offers an optional 5-year warranty for the hydrogen sulphide, oxygen and carbon monoxide monitors.

Robust and long-lasting
Protective rubber ensures that the casing of the Dräger Pac 7000 is particularly shock-proof. The device meets the strict dust and water protection requirements specified in IP 68. The electromagnetic resistance has also been optimised. Dräger has designed the Dräger Pac 7000 for unlimited lifetime. When needed, the sensors can be simply replaced.

Fast bump tests with the Dräger Bump Test Station
To perform an automatic function test with a known gas concentration within a matter of seconds, the device is simply inserted into the Dräger Bump Test Station. The display informs the user if the bump test (function test) was successful. If the test is not performed within a certain time frame, the device can be set-up to deactivate itself.

Triple alarm for extra safety
As soon as the adjustable alarm thresholds are exceeded, or values fall below the configured oxygen concentration, the Dräger Pac 7000 immediately issues an audible, visual and vibrating alarm. In addition, the device is also equipped with adjustable TWA and STEL alarms. The user is also warned when the battery is low or a functional error has occurred.
  • Measures carbon monoxide, hydrogen sulphide, or oxygen
  • No limit to the service life of the device
  • Event logger for up to 60 events
  • Service: Easy to replace batteries and sensors
    Replaceable dust and water filters
  • Warranty of 2 years*
  • Rapid functional tests on site
  • Measures carbon dioxide, sulphur dioxide, chlorine, hydrogen cyanide, ammonia, nitrogen dioxide, nitric oxide, phosphine, or organic vapours
  • Optional 5 year warranty* for the H2S, O2, and CO devices
  • Data logger for storage of gas concentrations and events with date and time (120 hours at 1 record per minute)
  • Configurable TWA and STEL alarms
  • Recording maximum concentrations
  • Automatic function test option
  • Estimated sensor service life of 5 - 8 years

* on the electronics, with the exception of the battery

VariationsMeasuring typeMeasuring rangeAlarm threshold
A1/A2 (standard)
ResolutionResponse time T90
AH2S 1)0 - 200 ppm5 /10 ppm1 ppm13 sec.
BH2S 2)0 - 200 ppm10 /20 ppm1 ppm13 sec.
CH2S0 - 200 ppmcustomer request1 ppm13 sec.
DH2S LC0 - 200 ppmcustomer request0,1 ppm13 sec.
EO2 1)0 - 25 Vol.-%19 /23 Vol.-%0,1 Vol.-%20 sec.
FO2 2)0 - 25 Vol.-%19,5 /23,5 Vol.-%0,1 Vol.-%20 sec.
GO2 0 - 25 Vol.-%customer request0,1 Vol.-%20 sec.
HCO 1)0 - 1999 ppm30 /60 ppm2 ppm11 sec.
ICO0 - 1999 ppmcustomer request2 ppm11 sec.
JCO 2)0 - 1999 ppm35 /50 ppm2 ppm11 sec.
KCO LC0 - 1999 ppm30 /60 ppm1 ppm15 sec.
LCO20 - 5 Vol.-%customer request0,1 Vol.-%30 sec. (T50)
MCI20 - 20 ppmcustomer request0,05 ppm30 sec.
NHCN0 - 50 ppmcustomer request0,1 ppm10 sec. (T50)
OHCN PC0 - 50 ppmcustomer request0,5 ppm10 sec. (T50)
PNH30 - 300 ppmcustomer request1 ppm10 sec. (T50)
QNO20 - 50 ppmcustomer request0,1 ppm15 sec.
RNO0 - 200 ppmcustomer request1 ppm10 sec.
SPH30 - 20 ppmcustomer request0,01 ppm10 sec.
TOV0 - 200 ppmcustomer request0,5 ppm20 sec. (T50)
UOV-A0 - 200 ppmcustomer request1 ppm40 sec. (T50)
VSO20 - 100 ppmcustomer request1 ppm15 sec.
WH2S 3)0 - 100 ppmcustomer request1 ppm13 sec.
XO2 3)0 - 25 Vol.-%customer request1 Vol.-%20 sec.
YCO 3)0 - 1999 ppmcustomer request2 ppm11 sec.



1) Standard configuration europe
2) Standard configuration North America
3) 5-years warranty