Innovative measurement technology from PCE Instruments
In our online range you will discover innovative measuring instruments such as hand-held meters, dugout meters and tools for measurement, analysis and investigation. The reliable technology of the PCE Instruments Crowcon Gas Meter Gas-Pro-1 helps you to determine really detailed measurements and to arrive at very accurate values. An insensitive housing but also the latest processes are guarantors for quality and reliability of the Pro-1. Further benefits of the measuring instruments from PCE Instruments are a high degree of flexibility due to the handy construction and compact designs as well as the possibility, model, to record your data digitally and thus store them in the best possible way. In addition, depending on the model, you can count the following points among the equipment:
- adjustable measuring times
- user-friendly operation
- the option to add monitoring programmes
- a safe and waterproof design
- and, depending on the model, much more. We will be happy to advise you on this.
All features and functions of the Pro-1 at a glance
In addition to the safety factor, the reliable acquisition of information is playing an increasingly important role in the numerous fields of application in laboratories and industry. The measuring technology from PCE Instruments works quickly and very accurately and provides you with reproducible analysis results in your field of work. Like most of the other measuring instruments of the manufacturer, this model is also battery- and/or accumulator-operated and can therefore be transported without any problems. Here you get an overview of the technical details of the Pro-1:
Measurement type: hand-held measuring device, industrial safety measuring device, gas measuring deviceDisplay: LCDWeight: 340 g (4 gases without pump), 380 g (5 gases with pump)Dimensions (in mm): 130 x 82 x 43Housing material: IP 65 / 67Power supply: Battery, rechargeable battery
Would you like more detailed information about the Pro-1 from PCE Instruments?
Would you like to learn more?
Our team of expert consultants will make sure you get the best instruments for your field. Do you have questions about the different versions, their functions or the respective manufacturers?
We look forward to hearing from you and will be happy to help. You can reach us by phone at +49 (0)30-403 667 940 or by e-mail at [email protected].
Dimensions (in mm):
|
130 x 82 x 43
|
Alarm signal:
|
Vibrationopticalacoustic
|
Display (metrology):
|
LCD
|
Housing (metrology):
|
IP 65 / 67
|
Weight, approx.:
|
380 g (5 gases with pump)340 g (4 gases without pump)
|
Measurement type:
|
Gas measuring deviceOccupational safety and health measuring deviceHand-held measuring instrument
|
Standards:
|
ATEX II 2G Ex ia d IIC T4 GbEN 61779IECEx- Ex ia d IIC T4EN 60079-29EN 50271EN 50270EN 50104EN 45544cUL: Class 1, Div 1, Groups A, B, C, DUL: Class 1, Div 1, Groups A,B,C,D
|
Interfaces:
|
USB
|
Power supply via:
|
BatteryBattery
|
Dimensions: |
× × cm |
PCE Crowcon Gas Meter |
Gas-Pro-1 |
Audible alarms |
95 dB (A) |
|
Regular control tone, can be switched off |
Optical alarm |
special bright LEDs, flashing red/blue |
|
Detectable from any viewing angle |
Vibrating alarm |
in addition to visual and audible |
|
Warning the gas detector vibrates |
Display |
bright head side LCD two color |
|
changes from green to red on alarm |
Measurement memory |
50 hours at 10 sec interval |
Power supply |
Lithium ion battery (Li-ion) |
|
approx. 19 hrs. in diffusion mode |
|
approx. 17 hrs. in pump mode |
Gehäuseklasse |
IP 65 / 67 |
Dimension |
130 x 82 x 43 mm (H x W x D) |
Weight |
340 g 4 gases without pump |
|
380 g 5 gases with pump |
Environmental conditions |
-20 °C to 50 °C |
|
20% to 90% RH non-condensing |
Standards/ Codes |
EN 60079-29 |
|
EN 45544 |
|
EN 50104 |
|
EN 50270 |
|
EN 50271 |
|
EN 61779 |
Approval |
ATEX - II 2G Ex ia d IIC T4 Gb |
|
IECEx - Ex ia d IIC T4 |
|
UL: Class 1, Div 1, Groups A, B, C, D |
|
cUL: Class 1, Div 1, Groups A, B, C, D |
PC interface |
Gerätespecific USB cable |
Typical measurement ranges and alarm settings |
|
|
|
Parameters / Gas |
Symbol |
Range |
Steps |
Flammable gases 1 |
LEL (catalytic) |
0 to 100 % LEL (LEL) |
1 % |
Oxygen |
O2 |
0 to 25 % by volume |
0.1% |
Carbon monoxide |
CO |
(CO) 0 to 500 ppm |
(CO) 1 ppm |
Hydrogen sulfide 2 |
H2S |
(H2S) 0 to 100 ppm |
(H2S) 0.1 ppm |
Other sensors on request! |
|
|
|
Ammonia |
NH3 |
0 to 100 ppm |
1 ppm |
Sulphur dioxide |
SO2 |
0 to 10 ppm |
0.1 ppm |
Ozone |
O3 |
0 to 1 ppm |
0.01 ppm |
Chlorine |
CI2 |
0 to 100 ppm |
0.1 ppm |
Chlorine dioxide |
CIO2 |
0 to 1 ppm |
0.01 ppm |
Nitrogen Monoxide |
NO |
0 to 1000 ppm |
1 ppm |
Nitrogen dioxide |
NO2 |
0 to 100 ppm |
0.1 ppm |
Flammable Gases |
UEG (Infrared) |
0 to 100 % LEL (LEL) |
1 % |
1) Standard calibration on methane, butane, pentane and ethylene further calibrations on request
2) Combi sensor
Attention changed maintenance instructions for gas detectors! According to ATEX and BG regulations (T021 and T023), all mobile gas detectors
must be subjected to a visual inspection and a display test before each use or once a day.
Maintenance and recalibration: You can send the gas detector to us for maintenance and calibration (e.g. every six months). The gas detector is
then disassembled, cleaned and recalibrated. If a sensor is no longer calibrated or its service life has expired, you will be
informed of this. Replacement sensors are also on offer.
This gas detector is approved according to ATEX. What does that mean?
This gas detector is approved according to the AZEX standard. The ATEX product directive (also unofficially referred to as ''ATEX 95'' because of the relevant
Art. 95 of the EC Treaty on the free movement of goods) of the European Parliament and of the Council on the approximation of the laws of the
Member States relating to a gas detection system or protective system intended for use in potentially explosive atmospheres lays down the rules for the
marketing of products used in such atmospheres. The Directive contains in Annex II the essential health and
safety requirements which must be observed by the manufacturer and then demonstrated by an appropriate conformity assessment procedure.
Our gas detector meets all current standards of the EU.
Scope of delivery:
1 x Gas detector Gas-Pro-1
1 x Charger
1 x Alligator clip with ringöse
1 x Operating instructions
1 x Calibration certificate
1 x Suction cap as well as a sample hose (suction version).