Here in our online catalogue you will find an overview of excellent measurement technology such as force gauges, moisture analyzers, data loggers and numerous compact and mobile devices for analyses and investigations. The NDL 10 from our manufacturer PCE Instruments supports you with a smart design to implement your work as optimally as possible. An insensitive outer housing, but also the modern processes, ensure you value stability and reliability. Additional special features of the manufacturer's devices are a high degree of flexibility through a handy construction and functional designs as well as the possibility, device type, to record your data digitally and thus store them efficiently. At the same time, depending on the model, you can count the following features among the equipment:

  • adjustable measuring times
  • user-friendly menu navigation
  • the possibility to add tools for monitoring
  • a safe, robust and waterproof construction
  • and, depending on the model, much more. We will be happy to advise you on this.

All technical features of the NDL 10 at a glance

In addition to safety, the protected acquisition of data plays a relevant role in very different working areas of laboratory and industry. For this reason, the has a memory medium (SD card 1 to 16 GB, internal memory) with which you can conveniently record and store your measured values. The measuring technology of the manufacturer PCE Instruments works quickly and precisely and provides you with reproducible results in any working environment. Like many of the manufacturer's other measuring instruments, the NDL 10 is battery- and/or accumulator-powered and can therefore be easily transported. The option of automatic switch-off (adjustable) additionally guarantees you energy-efficient working. Take a look at all the details of the PCE Instruments dB data logger PCE-NDL 10:

Measurement type: Data loggerDisplay: LCD, backlitWeight: 250 gDimensions (in mm): 132 x 80 x 32Memory medium: SD card 1 to 16 GB, internal memoryPower supply: Battery

Do you need more detailed information about the NDL 10?

Get to know more features of this model!

Our team of trained professionals will make sure you get the best materials for your application. Do you have questions about the different instruments, their functions or the respective brand manufacturers?

We look forward to hearing from you and will be happy to assist you. You can reach us by phone at +49 (0)30-403 667 940 or by e-mail at [email protected].


Dimensions (in mm): 132 x 80 x 32
Display (metrology): backlitLCD
Automatic switch off: adjustable
Weight, approx.: 250 g
Measurement type: Data logger
Interfaces: USBRS-232
Power supply via: Battery
Storage medium: SD card 1 to 16 GBInternal memory
Shipping weight: 1,25 Kg
Product weight: 0,25 Kg
Dimensions: × × cm
.
PCE dB data logger PCE-NDL 10
Measurement type SPL: Sound pressure level
Dose: Prüflärm exposure
Measurement Range SPL: Auto 30 to 130 dB
Dose: 70 to 130 dB
Resolution0.1 dB
Measurement functions dB (A and C frequency weighting)
Time weighting (fast and slow)
Data-HOLD
Record function (MAX and MIN)
Measurement accuracy (at 23 ±5 °C, below 94 dB) 31.5 Hz / ±3.0 dB
63 Hz / ±2.0 dB
125 Hz / ±1.5 dB
250 Hz / ±1.5 dB
500 Hz / ±1.5 dB
1 KHz / ±1.0 dB
2 KHz / ±2.0 dB
4 KHz / ±3.0 dB
8 KHz / ±5.0 dB
Frequency weighting A and C
Time rating Fast: t = 125 ms
Slow: t = 1 s
Data-HOLD Freeze the displayed measured value
Function selection SPL Automatic measurement range: 30 to 130 dB
Function selection dose measurement

Limit: 70 to 90 dB (in 1 dB increments)
Assessment level: 80, 84, 85, 90 dB
Change rate: 3, 4, 5 or 6 dB
Frequency 31.5 to 8000 Hz
Type of microphone electric condenser microphone
Grö&Airfoil;e Microphone Diameter 12.7 mm
Calibration Internal calibration at 94 dB with calibrator PCE-SC 42 possible
automatic data logger Loginterval: 1 to 3600 seconds
manual data logger manual log interval (interval must be set to ''0'')
Memory options Internal memory for up to 16000 readings
SD memory card (1 to 16 GB)
Measurement error =0.1% of total stored data
Continuing settings Time and date settings
Sample rate
Automatic shutdown
Acoustic alarm on/off
Setting decimal point during storage
Format settings SD card
Setting A / C frequency weighting
Measurement out of range Display of ''----''
Memory recall Maximum and minimum value
Sampling rate approx. 1 x / second
Data output RS-232
USB
automatic shutdown adjustable
Operating conditions 0 to +50, <85 % r.h.
Power supply Battery
Mains voltage
Display Backlit LCD
Display size 50 x 30 mm
Weight 250 g
Dimensions 132 x 80 x 32 mm
Scope of delivery:
  • 1 x PCE-NDL 10 air dosimeter
  • 1 x microphone with retaining clip
  • 1 x carrying bag
  • 1 x carrying strap
  • 1 x power adapter