ET 5000 from PCE Instruments the measuring device of the extra class
In our extensive product range you will find a lot of measuring instruments which are used in countless working areas. With its innovative, sophisticated technology, the ET 5000 provides extremely meaningful results. Our customers use the ET 5000 in various professional fields. A sturdy housing and simple technology guarantee the ET 5000's lasting value and reliability. Convince yourself of further advantages such as a high degree of flexibility due to the mobile design and fast data acquisition and/or storage. On top of that, depending on the instrument, you can count the following functions among its components:
- variable and individually adjustable measuring times
- user-friendly menu navigation
- the option to add monitoring programmes
- a special level of safety and protection against splash water
- and, depending on the model, much more. We will be happy to advise you on this.
An overview of the technical features of the unit
In addition to the safety factor, the controlled acquisition of data is playing an increasingly important role in numerous areas of laboratory and industrial work. The xx from PCE Instruments works quickly and very accurately and provides you with reproducible measurement results in your field of application. Like most of the other measuring instruments of the manufacturer, this model is also battery- and/or accumulator-operated and can therefore be transported without any problems. Take a look at all the features of this model:
Measurement type: hand-held meter, earthing meterDisplay: LCD, backlitWeight: 2.5 kgDimensions (in mm): 260 x 125 x 280Power supply: Battery, mains adapter, rechargeable battery
Our trained service team will be happy to provide you with more detailed information on functions and features.
Our advisors answer your questions
Our experienced team of consultants guarantees that you will receive the ideal measuring equipment for your requirements. Do you have questions about the different measurement technologies, their advantages or their manufacturers?
We will be happy to assist you and are available around the clock by phone at +49 (0)30-403 667 940 or by e-mail at [email protected]. We look forward to hearing from you!
Dimensions (in mm):
|
260 x 125 x 280
|
Display (metrology):
|
backlitLCD
|
Weight, approx.:
|
2,5 kg
|
Measurement type:
|
Earth meterHand-held measuring instrument
|
Standards:
|
IEC 61326-1:1997 AEN 61010-1:2001EN 61010-031:2002EN 61000-3-2:2000CAT III 300 VPollution degree 2
|
Interfaces:
|
USB-BMeasuring connection: E,ES,S,HCharging connectionPliers connection
|
Power supply via:
|
BatteryPower supply unitBattery
|
Shipping weight: |
3,50 Kg |
Product weight: |
2,50 Kg |
Dimensions: |
× × cm |
PCE grounding meter |
PCE-ET 5000 |
3-pole grounding resistor |
|
Test voltage |
20, 48 V AC |
Test frequency |
94 Hz |
|
105 Hz |
|
111 Hz |
|
128 Hz |
|
AFC |
Short circuit current |
250 mA |
Test time |
26 seconds |
Probe resistance Rs |
<100 kOhm |
Auxiliary grounding resistor Rh |
<100 kOhm |
Resistance |
0.001 ohms |
Measuring range Re |
0.02 ohms to 300 k ohms |
Accuracy |
±(5% + 10 digits) |
ST |
<24 V |
Fst |
16 to 400 Hz |
Note 1* |
|
|
|
4-pole grounding resistor |
|
Test voltage |
20, 48 V AC |
Test frequency |
94 Hz |
|
105 Hz |
|
111 Hz |
|
128 Hz |
|
AFC |
Short circuit current |
250 mA |
Test time |
30 seconds |
Probe resistance Rs |
<100 kOhm |
Auxiliary grounding resistor Rh |
<100 kOhm |
Resistance |
0.001 ohms |
Measuring range Re |
0.02 ohms to 300 k ohms |
Accuracy |
±(5% + 10 digits) |
ST |
<24 V |
Fst |
16 to 400 Hz |
Note 2* |
|
|
|
3-pole grounding resistor with current clamp |
|
Test voltage |
20, 48 V AC |
Test frequency |
94 Hz |
|
105 Hz |
|
111 Hz |
|
128 Hz |
|
AFC |
Short circuit current |
250 mA |
Test time |
26 seconds |
Probe resistance Rs |
<100 kOhm |
Auxiliary grounding resistor Rh |
<100 kOhm |
Resistance |
0.001 ohms |
Measuring range Re |
0.02 ohms to 20 k ohms |
Accuracy |
±(5% + 10 digits) |
ST |
<24 V |
Fst |
16 to 400 Hz |
Note 3* |
|
|
|
4-pole grounding resistor with current clamp |
|
Test voltage |
20, 48 V AC |
Test frequency |
94 Hz |
|
105 Hz |
|
111 Hz |
|
128 Hz |
|
AFC |
Short circuit current |
250 mA |
Test time |
26 seconds |
Probe resistance Rs |
<100 kOhm |
Auxiliary grounding resistor Rh |
<100 kOhm |
Resistance |
0.001 ohms |
Measuring range Re |
0.02 ohms to 20 k ohms |
Accuracy |
±(5% + 10 digits) |
ST |
<24 V |
Fst |
16 to 400 Hz |
Note 4* |
|
|
|
Grounding resistance only with current clamps |
|
Test voltage |
48 V AC |
Test frequency |
94 Hz |
|
105 Hz |
|
111 Hz |
|
128 Hz |
|
AFC |
Short circuit current |
250 mA |
Test time |
26 seconds |
Measuring range Re |
0.02 ohms to 150 ohms |
Resolution |
0.001 ohms |
Accuracy |
±(5% + 10 digits) |
ST |
<24 V |
Fst |
16 to 400 Hz |
Note 5* |
|
|
|
Ground resistance (distance resistance) |
|
Test voltage |
20, 48 V AC |
Test frequency |
94 Hz |
|
105 Hz |
|
111 Hz |
|
128 Hz |
|
AFC |
Short circuit current |
250 mA |
Test time |
26 seconds |
Resolution |
0.001 ohms * m |
Measuring range Re |
0.02 ohm to 1000 kOhm * m |
Accuracy |
±(5% + 10 digits) |
|
|
2-pole resistance measurement (AC) |
|
Test voltage |
20 V AC |
Test frequency |
94 Hz |
|
105 Hz |
|
111 Hz |
|
128 Hz |
|
AFC |
Short circuit current |
250 mA |
Test time |
26 seconds |
Measuring range Re |
0.02 ohms to 300 k ohms |
Resolution |
0.001 ohms |
Accuracy |
±(5% + 10 digits) |
ST |
<24 V |
Fst |
16 to 400 Hz |
|
|
2-pole resistance measurement (DC) |
|
Test voltage |
20 V DC |
Short circuit current |
250 mA |
Test time |
26 seconds |
Measuring range Re |
0.02 to 3 kOhm |
Resolution |
0.001 ohms |
Accuracy |
±(5% + 10 digits) |
ST |
<3 V |
Fst |
16 to 400 Hz |
|
|
4-pole resistance measurement (DC) |
|
Test voltage |
20 V DC |
Short circuit current |
250 mA |
Test time |
26 seconds |
Measuring range Re |
0.02 ohms to 3 k ohms |
Resolution |
0.001 ohms |
Accuracy |
±(5% + 10 digits) |
ST |
<3 V |
Fst |
16 to 400 Hz |
|
|
Line compensation |
|
Test voltage |
20, 48 V AC |
Test frequency |
94 Hz |
|
105 Hz |
|
111 Hz |
|
128 Hz |
|
AFC |
Short circuit current |
250 mA |
Test time |
26 seconds |
Resolution |
0.001 ohms |
Measuring range Re |
0.02 ohms to 30 ohms |
Accuracy |
±(3% + 10 digits) |
ST |
<24 V |
Fst |
16 to 400 Hz |
Stör voltage |
|
Measuring range |
±50 V DC |
|
1 to 50 V AC |
Resolution |
0.1 V |
Accuracy |
±(5 % + 5 digits) |
Current |
|
Measuring range |
20 mA to 2 A |
Resolution |
1 mA |
Accuracy |
±(5% + 5 digits) |
Stör frequency |
|
Measuring range |
16 to 400 Hz |
Resolution |
1 Hz |
Accuracy |
±(1% + 10 digits) |
Other specifications |
|
Data storage |
100 readings |
Operating conditions |
0 to 40 °C |
|
<80% RH (non-condensing) |
Environmental conditions for charging the battery | .
10 to 40 °C |
|
<80% RH (non-condensing) |
Storage conditions |
-10 to 50 °C |
|
<90% RH (non-condensing) |
Storage conditions for the battery |
-20 to 30 °C |
|
<80% RH (non-condensing) |
Bearing height |
<12,000 m |
Operating height |
<2,000 m |
Clamp diameter |
51 mm |
Display |
Backlit LCD, 9999 digits |
Indication measuring range überschritten |
> LIMIT |
Display measuring range undershot |
- |
Measurement frequency ground resistance / leakage current |
1 Hz (If the average value function is activated: one value every four seconds) |
Measurement frequency voltage measurement |
2 Hz |
Measurement frequency voltage |
4 Hz |
Measurement frequency Stör frequency |
1 Hz |
Measurement frequency stör current |
1 Hz |
Interfaces |
Measurement port: E, ES, S, H |
|
Tong connector |
|
USB-B |
|
charging port |
Power supply batteries |
6 x 1.5 V D LR14 batteries |
Power supply battery |
1 x 7.2 V nickel-metal hydride rechargeable battery pack |
Power supply power supply |
Primär: 100 to 240 V, 50 to 60 Hz |
|
Secondär: 12 V, 3 A |
max. power consumption with power supply |
15 VA |
max. power consumption with battery or rechargeable battery |
6 VA |
Runtime in battery mode |
approx. 5 hours |
Runtime in battery |
approx. 9 hours (without backlight) |
maximum input voltage |
|
maximum input voltage referenced to ground |
300 V rms (CAT III) |
Insulation strength |
6880 V AC: 15 seconds |
&Voltage protection |
250 V AC between terminals |
Dimensions |
260 x 125 x 280 mm |
Weight |
approx. 2.5 kg |
Standards |
EN61010-1:2001 |
|
EN61010-031:2002 |
|
Pollution degree 2 |
|
CAT III 300 V |
|
EMC: EN61000-3-2:2000 |
|
EMC: IEC61326-1:1997 A |
* Note 1: Accuracy is guaranteed in an environment of 0 to 28 °C, < 80% RH (non-condensing).
Reaction time <15 seconds (Time required to achieve the specified accuracy after the start of measurement with the average function turned off.)
* Note 2: Accuracy is maintained in an environment of 0 to 28 °C, < 80 % RH (non-condensing).
Reaction time <25 seconds (Time required to achieve the specified accuracy after the start of measurement with the average function turned off.)
* Note 3: Accuracy is maintained in an environment of 0 to 28 °C, < 80 % RH (non-condensing).
Reaction time <25 seconds (Time required to achieve the specified accuracy after the start of measurement with the average function turned off.)
If the current at the current clamp is too low, the measurement may be canceled.
* Note 4: Accuracy is guaranteed in an environment of 0 to 28 °C, < 80% RH (non-condensing).
Reaction time <25 seconds (Time required to achieve the specified accuracy, after starting measurement with the average function turned off.)
If the current at the current clamp is too low, the measurement may be canceled.
* Note 5: Accuracy is guaranteed in an environment of 0 to 28 °C, < 80% RH (non-condensing).
Reaction time <25 seconds (Required time to achieve the specified accuracy after the start of measurement with the average function turned off.)
If the current at the current clamp is too low, the measurement may be canceled.
Scope of delivery:
- 1 x PCE-ET 5000 grounding meter
- 4 x alligator clips
- 1 x Power supply
- 1 x USB cable
- 4 x test cables
- 1 x voltage clamp cable
- 1 x power clamp cable
- 6 x 1.5 V C batteries
- 2 x current clamps
- 1 x rechargeable Ni-MH battery
- 4 x plug-in samples
- 1 x instruction manual