ELGA water treatment system PURELAB Chorus 1 Complete
starting from
6.748,80 €
Manufacturers suggested retail price:
7.104,00 €
Excluding 19% VAT. ,
plus
(Standard)
(including 19% VAT. 8.031,07 €)
- Model
-
There are variations of this item. Please select the variation you wish.
ELGA water treatment system PURELAB Chorus 1 Complete
The compact system produces type I ultrapure water from untreated drinking water at up to 20 l/h (withdrawal >1.5 l/min).
For consistently high water quality at low operating costs, the treated water recirculates from the tank to the withdrawal point via the UV lamp and deionisation.
The colour display shows important water parameters, status messages and the tank level at a glance.
Alarm values can be selected for permeate quality, product water quality and temperature.
The system can be optionally combined with up to three Halo dispensers for ultra-pure water extraction and final filters.
- Ultra-pure water directly from drinking water
- Space-saving installation options: Wall, table, under-table, on tanks
- Recirculation for guaranteed purity
- Data acquisition for validation
Width (water treatment):
|
376 mm
|
Booster pump:
|
withwithout
|
Height (water treatment):
|
679 mm
|
Ideal for:
|
LaboratoriesImmunochemistryMolecular biologySpectrophotometryAtomic spectroscopyGas chromatographyMass spectrometryLiquid chromatographyElectrochemistry
|
Power:
|
10 l/h20 l/h
|
Modules:
|
RO-moduleUV lamp
|
Depth (water treatment):
|
353 mm
|
Storage tank - tank:
|
optional
|
Water treatment type:
|
ultrapure water system
|
Water source:
|
from the water mains
|
Dimensions: |
× × cm |
ELGA PURELAB |
Chorus 1 Complete 10 l/h |
Chorus 1 Complete 10 l/h, BP |
Chorus 1 Complete 20 l/h |
Chorus 1 Complete 20 l/h, BP |
Production rate |
maximum 10 l/h
(4 bar inlet pressure at 15 °C) |
maximum 10 l/h |
maximum 20 l/h
(4 bar inlet pressure at 15 °C) |
maximum 20 l/h |
Flow rate at the tap |
up to 1.5 l/min |
up to 1.5 l/min |
up to 1.5 l/min |
up to 1.5 l/min |
Inorganic substances At 25 °C |
18.2 mega-ohm x cm, 0.055 µS/cm |
18.2 mega-ohm x cm, 0.055 µS/cm |
18.2 mega-ohm x cm, 0.055 µS/cm |
18.2 mega-ohm x cm, 0.055 µS/cm |
Organic substances (TOC) |
<5 ppb |
<5 ppb |
<5 ppb |
<5 ppb |
Bacteria |
<0.001 CFU/ml
(with POU filter LC134/LC145/LC197) |
<0.001 CFU/ml
(with POU filter LC134/LC145/LC197) |
<0.001 CFU/ml
(with POU filter LC134/LC145/LC197) |
<0.001 CFU/ml
(with POU filter LC134/LC145/LC197) |
Bacterial endotoxins |
<0.001 CFU/ml
(with biofilter LC197) |
<0.001 EU/ml
(with POU filter LC197) |
<0.001 EU/ml
(with biofilter LC197) |
<0.001 EU/ml
(with biofilter LC197) |
PH value |
neutral |
neutral |
neutral |
neutral |
Particles |
0.2 µm
(with POU filter LC134/LC145/LC197) |
0.2 µm
(with POU filter LC134/LC145/LC197) |
0.2 µm
(with POU filter LC134/LC145/LC197) |
0.2 µm
(with POU filter LC134/LC145/ LC197) |
Rnase |
<1 pg/ml |
<1 pg/ml |
<1 pg/ml |
<1 pg/ml |
Dnase |
<5 pg/ml |
<5 pg/ml |
<5 pg/ml |
<5 pg/ml |
Fouling index |
10 maximum |
10 maximum |
10 maximum |
10 maximum |
Free chlorine |
0.5 ppm maximum |
0.5 ppm maximum |
0.5 ppm maximum |
0.5 ppm maximum |
CO2 |
<20 ppm (recommendation) |
<20 ppm (recommendation) |
<20 ppm (recommendation) |
<20 ppm (recommendation) |
Silicate |
maximum 30 ppm |
maximum 30 ppm |
maximum 30 ppm |
maximum 30 ppm |
Temperature |
1-35 ºC (recommended 10-15 °C) |
1-35 ºC (recommended 10-15 °C) |
1-35 ºC (recommended 10-15 °C) |
1-35 ºC (recommended 10-15 °C) |
Flow rate |
130 l/h maximum |
130 l/h maximum |
130 l/h maximum |
130 l/h maximum |
Feed water pressure |
at least 4 bar, maximum 6 bar
(at >6 bar a pressure reducer is required,
optional accessory) |
minimum 0.5 bar, maximum 2.0 bar
(at >2 bar, a pressure reducer is required,
optional accessories) |
at least 4 bar, maximum 6 bar
(at >6 bar a pressure reducer is required,
optional accessories) |
at least 0.5 bar, maximum 2.0 bar
(at >2 bar a pressure reducer is required,
optional accessories) |
Outlet (free outlet) |
up to 2 l/min |
up to 2 l/min |
up to 2 l/min |
up to 2 l/min |
Installation |
on / under table or wall |
on / under table or wall |
on / under table or wall |
on / under table or wall |
Mains voltage |
100-240 V AC, 50-60 Hz |
100-240 V AC, 50-60 Hz |
100-240 V AC, 50-60 Hz |
100-240 V AC, 50-60 Hz |
Input power |
maximum 155 VA |
Maximum 155 VA |
maximum 155 VA |
maximum 155 VA |
System voltage |
24 V DC |
24 V DC |
24 V DC |
24 V DC |
Low-noise operation at |
<45 dBA |
<45 dBA |
<45 dBA |
<45 dBA |
|
|
|
|
|
Height |
679 mm |
679 mm |
679 mm |
679 mm |
Width |
376 mm |
376 mm |
376 mm |
376 mm |
Depth |
353 mm |
353 mm |
353 mm |
353 mm |
Weight |
15 kg |
17 kg |
16 kg |
18 kg |
PURELAB Chorus 1 Complete systems are delivered ready for use including LC241 pre-treatment cartridge, 1-2 x LC240 RO module, LC275 treatment cartridge, LC210-02 UV lamp,
LA762 Basic Installation Kit, LA233 Bypass Block and 1 x POWE40855 Power Supply.
A PURELAB Chorus supply tank is required to operate a PURELAB Chorus 1 Complete system.